A case of redo tricuspid valve repair after neonatal cone operation for Ebstein’s anomaly

  • Case Report
  • Published:
General Thoracic and Cardiovascular Surgery Aims and scope Submit manuscript

Abstract

Cone reconstruction for Ebstein’s anomaly, although effective, is challenging in neonatal cases. Very few reports have discussed recurrent regurgitation. Herein, we report a successful redo tricuspid valve repair for recurrent regurgitation 5 years after cone reconstruction. A 5-year-old boy underwent cone reconstruction for Ebstein’s anomaly in the neonatal period. Although tricuspid regurgitation reduced initially, it subsequently worsened. The mechanisms of regurgitation are dilatation of the anteroseptal commissure, indentation in the septal leaflet, and foreshortening of the anterior leaflet. Augmentation of the anterior leaflet using an elliptic autologous pericardium and mending of the gaping commissure and indentation markedly reduced the regurgitation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. da Silva JP, Baumgratz JF, da Fonseca L, Franchi SM, Lopes LM, Tavares GM, et al. The cone reconstruction of the tricuspid valve in Ebstein’s anomaly. The operation: early and midterm results. J Thorac Cardiovasc Surg. 2007; 133: 215–23.

  2. Ibrahim M, Tsang V, Caruana M, Hughes ML, Jenkyns S, Perdreau E, et al. Cone reconstruction for Ebstein’s anomaly: Patient outcomes, biventricular function, and cardiopulmonary exercise capacity. J Thorac Cardiovasc Surg. 2015;149:1144–50.

    Article  Google Scholar 

  3. Mizuno M, Hoashi T, Sakaguchi H, Kagisaki K, Kitano M, Kurosaki K, et al. Application of cone reconstruction for neonatal Ebstein anomaly or tricuspid valve dysplasia. Ann Thorac Surg. 2016;101:1811–7.

    Article  Google Scholar 

  4. Alderweireldt AS, De Wolf D. Percutaneous closure of paravalvular leak after cone repair for Ebstein’s anomaly. Catheter Cardiovasc Interv. 2019;93:E46–8.

    Article  Google Scholar 

  5. Dearani J, Said S, O’Leary P, Burkhart H, Barnes R, Cetta F. Anatomic repair of Ebstein’s malformation: lessons learned with cone reconstruction. Ann Thorac Surg. 2013;95:220–8.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Junya Nabeshima.

Ethics declarations

Conflict of interest

None.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Below is the link to the electronic supplementary material.

Supplementary file1 (PDF 511 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Nabeshima, J., Yamagishi, M., Maeda, Y. et al. A case of redo tricuspid valve repair after neonatal cone operation for Ebstein’s anomaly. Gen Thorac Cardiovasc Surg 70, 289–291 (2022). https://doi.org/10.1007/s11748-021-01742-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11748-021-01742-x

Keywords

Navigation