Abstract
We developed an amblyopia-training device, which can be used easily and inexpensively under binocular conditions with polarizing films. The device uses two polarizing films: one is attached to the training target (such as monitors and books), while the other is attached to the lens of glasses that cover the healthy eye with the absorption axis rotated 90 degrees. This allows the target to be presented only to the amblyopic eye under binocular conditions. Amblyopia training with this device was performed for 1 h per day in 14 patients with anisometropic amblyopia. The training resulted in a significant improvement in visual acuity, and a significant correlation was observed between the improvement in visual acuity and the adherence rate, indicating the effectiveness of the device for amblyopia training under binocular conditions.
Data availability
The data are not available for public access because of patient privacy concerns but are available from the corresponding author on reasonable request.
References
Multi-ethnic Pediatric Eye Disease Study Group: Prevalence of amblyopia and strabismus in African American and Hispanic children ages 6 to 72 months: the Multi-ethnic Pediatric Eye Disease Study. Ophthalmology 115, 1229–1236 (2008)
Totsuka, S., Handa, T., Ishikawa, H., et al.: Improvement of adherence with occlu-pad therapy for pediatric patients with amblyopia. Biomed. Res. Int. 2018, 2394562 (2018)
Iwata, Y., Handa, T., Ishikawa, H., et al.: Comparison between amblyopia treatment with glasses only and combination of glasses and open-type binocular “occlu-pad” device. Biomed. Res. Int. 2018, 2459696 (2018)
Holmes, J.M., Hanh, V.M., Lazar, E.L., et al.: Effect of a binocular iPad game vs part-time patching in children aged 5 to 12 years with amblyopia: a randomized clinical trial. JAMA Ophthalmol. 186, 104–1152 (2018)
Awan, M., Proudlock, F.A., Gottlob, I.: A randomized controlled trial of unilateral strabismic and mixed amblyopia using occlusion dose monitors to record compliance. Invest Ophthalmol Vis Sci. 46(4), 1435–1439 (2005)
Loudon, S.E., Fronius, M., Looman, C.W.N., et al.: Predictors and a remedy for noncompliance with amblyopia therapy in children measured with the occlusion dose monitor. Invest Ophthalmol Vis Sci. 47(10), 4393–4400 (2006)
Wallace, M.P., Steward, C.E., Moseley, M.J., et al.: Compliance with occlusion therapy for childhood amblyopia. Invest. Ophthalmol. Vis. Sci. 54(9), 6158–6166 (2013)
Iwata, Y., Handa, T., Ishikawa, H., et al.: Evaluation of the effects of the occlu-pad for the management of anisometropic amblyopia in children. Curr. Eye Res. 43(6), 785–787 (2018)
Funding
This work was supported by JSPS KAKENHI Grant Number JP40803200.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
None of the authors has any proprietary or financial interest in any of the materials or methods discussed.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Iwata, Y., Handa, T. & Ishikawa, H. Development of a new amblyopia-training device with polarizing films used under binocular conditions. Opt Rev 29, 59–61 (2022). https://doi.org/10.1007/s10043-021-00709-w
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10043-021-00709-w