Data availability
HJS, EHMK and RAB take responsibility for the integrity of the data and the accuracy of the analysis. The study protocol is available upon request.
References
Batllori M, Urra M, Uriarte E et al (2016) Randomized comparison of three transducer orientation approaches for ultrasound guided internal jugular venous cannulation. Br J Anaesth 116:370–376. https://doi.org/10.1093/bja/aev399
Blaivas M, Adhikari S (2009) An unseen danger: frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance. Crit Care Med 37:2345–2349. https://doi.org/10.1097/CCM.0b013e3181c0d9bb
French JLH, Raine-Fenning NJ, Hardman JG, Bedforth NM (2008) Pitfalls of ultrasound guided vascular access: the use of three/four-dimensional ultrasound. Anaesthesia 63:806–813. https://doi.org/10.1111/j.1365-2044.2008.05513.x
Panidapu N, Babu S, Koshy T et al (2020) Internal jugular vein cannulation using a 3- dimensional ultrasound probe in patients undergoing cardiac surgery: comparison between biplane view and short-axis view. J Cardiothorac Vasc Anesth. https://doi.org/10.1053/j.jvca.2020.08.021
Sauro J, Dumas JS (2009) Comparison of three one-question, post-task usability questionnaires. Conference on Human Factors in Computing Systems - Proceedings 1599–1608. https://doi.org/10.1145/1518701.1518946
Acknowledgements
3DUI Study Group: Joris van Houte, M.D., Cecile H. Kicken M.D., Ph.D. Renee J.C. van den Broek M.D., Leontien ter Horst M.D., Veerle Piot M.D. Department of Anaesthesiology, Catharina Hospital Eindhoven, Michelangelolaan 2, 5623 EJ Eindhoven, The Netherlands.
Funding
This study was an investigator-initiated study. Funding for acquisition of the Butterfly IQ + system was provided by the Catharina Hospital Research Fund.
Author information
Authors and Affiliations
Consortia
Contributions
Study concept and design: HJS, RAB and EHMK. Material preparation and data collection were performed by MIM, RJCvdB, JvH, CHK, LJM, LtH and VP. Data analysis was performed by HJS, RAB and EHMK. The first draft of the manuscript was written by HJS and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Conflicts of interest
LJM, EHMK and RAB have acted as clinical consultants for Philips Medical Research BV, Eindhoven, the Netherlands. All other authors declare no conflicts of interest.
Ethical approval
This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the institutional review board MEC-U (NL76278.100.20, Feb 5, 2021).
Consent to participate
Informed consent was obtained from all individual participants included in the study.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
The members of the 3DUI Study group are listed in the Acknowledgements section.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Scholten, H.J., Meesters, M.I., Montenij, L.J. et al. 3D biplane versus conventional 2D ultrasound imaging for internal jugular vein cannulation. Intensive Care Med 48, 236–237 (2022). https://doi.org/10.1007/s00134-021-06579-9
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00134-021-06579-9