2021 Volume 62 Issue 5 Pages 1012-1018
High-degree atrioventricular block (HAVB) or complete heart block (CHB) is a common complication associated with transcatheter aortic valve replacement (TAVR). However, some patients with HAVB/CHB recover with time. The results of electrophysiological studies (EPSs) using permanent pacemaker implantation (PPI) in patients with suspicious HAVB/CHB are considered controversial.
This study aimed to evaluate whether HAVB/CHB induction at the bedside using a temporary pacemaker can predict recurrence in patients who had recovered from HAVB/CHB after TAVR.
We enrolled a total of 11 patients who had recovered from HAVB/CHB and evaluated their electrophysiology using right ventricular pacing and/or procainamide administration.
HAVB/CHB induction was positive. Three patients tested positive for HAVB/CHB, whereas 8 tested negative. The ejection fraction and the interval between HAVB/CHB onset and EPS were found to be significant. HAVB/CHB positive patients underwent PPI. A patient with a balloon-expandable valve tested positive just before recovery of CHB, but tested negative 5 days later and was included in the negative group. The 4 patients who tested negative received a cardiovascular implantable electric device (CIED). We observed HAVB/CHB in 2 patients who had previously tested positive after 3 months. Among those who tested negative, those with CIED had no HAVB/CHB, and others showed neither HAVB/CHB on electrocardiogram nor experienced syncope or sudden death.
Our EPS revealed that HAVB/CHB induction may predict HAVB/CHB recurrence after TAVR. Valve type and EPS timing may affect the results.