Impact of implantation depth on outcomes of new-generation balloon-expandable transcatheter heart valves

  • Original Paper
  • Published:
Clinical Research in Cardiology Aims and scope Submit manuscript

Abstract

Background

Little is known about the impact of the ID on outcomes and device success using balloon-expandable devices. This study sought to analyze the impact of implantation depth (ID) on procedural outcomes.

Methods

In consecutive patients (n = 969) undergoing transfemoral TAVR with new-generation balloon-expandable prostheses, the mean ID (IDMean) was determined by aortography and categorized into low, correct, and high device position. Outcomes of interest were device success (VARC-2), paravalvular regurgitation (PVR) ≥ moderate, severe prosthesis-patient mismatch (PPM), permanent pacemaker implantation (PPI), and the composite of the three latter outcome measures (COMPPPP).

Results

IDMean was greater among patients with PPI (median 4.0 [interquartile range 2.0; 4.0] vs. 3.5 [1.5; 5.5] mm; p = 0.002), severe PPM (3.5 [1.5; 5.0] vs. 4.0 [2.0; 6.0] mm; p = 0.028), and COMPPPP (4.0 [2.0; 6.0] vs. 3.0 [1.5; 5.5] mm; p < 0.001) when compared with the respective groups without these complications. There was no significant association between IDMean and device success or PVR ≥ moderate.

Categorization into low (7.3%), correct (90.7%), and high (2.0%) device position showed significant discrimination with an increase of severe PPM, PPI, and COMPPPP with lower position, whereas device success was not significantly affected by position. Only PVR ≥ moderate showed an asymmetric distribution with highest rates in the high and low position group, which was non-significant. However, among patients without correct position the rate of device success was 45.6%.

Conclusions

A higher device position was associated with improved outcomes. Malpositioning without functional impairment should not be classified as device failure.

Graphic abstract

The odds ratio of IDMean was calculated by univariate logistic regression for each outcome variable, showing that with higher values of IDMean (i.e., low implantation depth), the risk of severe PPM, PPI, and COMPPPP increases. The bar charts under the heading “Position category” denote the frequency of each outcome measure across patients with high, correct, and low device position. The p values are derived from chi-squared test.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

Availability of data and material

Data will be made available on request.

References

  1. Siontis GCM, Overtchouk P, Cahill TJ et al (2019) Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of symptomatic severe aortic stenosis: an updated meta-analysis. Eur Heart J 40(38):3143–3153. https://doi.org/10.1093/eurheartj/ehz275

    Article  PubMed  Google Scholar 

  2. Barbanti M, Webb JG, Dvir D et al (2019) Residual challenges in TAVI: moving forward. EuroIntervention 15(10):857–866. https://doi.org/10.4244/EIJ-D-19-00788

    Article  PubMed  Google Scholar 

  3. Kappetein AP, Head SJ, Genereux P et al (2012) Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document (VARC-2). Eur J Cardiothorac Surg 42(5):S45-60. https://doi.org/10.1093/ejcts/ezs533

    Article  PubMed  Google Scholar 

  4. Petronio AS, Sinning JM, Van Mieghem N et al (2015) Optimal implantation depth and adherence to guidelines on permanent pacing to improve the results of transcatheter aortic valve replacement with the medtronic core valve system: the core valve prospective, international, post-market ADVANCE-II study JACC. Cardiovasc Interv 8(6):837–846. https://doi.org/10.1016/j.jcin.2015.02.005

    Article  Google Scholar 

  5. Vavuranakis M, Kariori M, Scott L et al (2018) Impact of “high” implantation on functionality of self-expandable bioprosthesis during the short- and long-term outcome of patients who undergo transcatheter aortic valve implantation: Is high implantation beneficial? Cardiovasc Ther 36(3):e12330. https://doi.org/10.1111/1755-5922.12330

    Article  PubMed  Google Scholar 

  6. Piayda K, Hellhammer K, Veulemans V et al (2020) Navigating the “optimal implantation depth” with a self-expandable TAVR device in daily clinical practice. JACC Cardiovasc Interv 13(6):679–688. https://doi.org/10.1016/j.jcin.2019.07.048

    Article  PubMed  Google Scholar 

  7. Husser O, Pellegrini C, Kessler T et al (2016) Predictors of permanent pacemaker implantations and new-onset conduction abnormalities with the SAPIEN 3 balloon-expandable transcatheter heart valve. JACC Cardiovasc Interv 9(3):244–254. https://doi.org/10.1016/j.jcin.2015.09.036

    Article  PubMed  Google Scholar 

  8. Mauri V, Reimann A, Stern D et al (2016) Predictors of permanent pacemaker implantation after transcatheter aortic valve replacement with the SAPIEN 3. JACC Cardiovasc Interv 9(21):2200–2209. https://doi.org/10.1016/j.jcin.2016.08.034

    Article  PubMed  Google Scholar 

  9. Sammour Y, Banerjee K, Kumar A et al (2021) Systematic approach to high implantation of SAPIEN-3 valve achieves a lower rate of conduction abnormalities including pacemaker implantation. Circ Cardiovasc Interv 14(1):e009407. https://doi.org/10.1161/CIRCINTERVENTIONS.120.009407

    Article  CAS  PubMed  Google Scholar 

  10. Joint Task Force on the Management of Valvular Heart Disease of the European Society of C, European Association for Cardio-Thoracic S et al (2012) Guidelines on the management of valvular heart disease (version 2012). Eur Heart J 33(19):2451–2496. https://doi.org/10.1093/eurheartj/ehs109

    Article  Google Scholar 

  11. Baumgartner H, Falk V, Bax JJ et al (2017) 2017 ESC/EACTS Guidelines for the management of valvular heart disease. Eur Heart J 38(36):2739–2791. https://doi.org/10.1093/eurheartj/ehx391

    Article  PubMed  Google Scholar 

  12. Kim WK, Praz F, Blumenstein J et al (2017) Transfemoral aortic valve implantation of Edwards SAPIEN 3 without predilatation. Catheter Cardiovasc Interv 89(1):E38–E43. https://doi.org/10.1002/ccd.26464

    Article  PubMed  Google Scholar 

  13. Kim WK, Mollmann H, Walther T et al (2021) Predictors of permanent pacemaker implantation after ACURATE neo transcatheter heart valve implantation. Pacing Clin Electrophysiol 44(2):410–415. https://doi.org/10.1111/pace.14155

    Article  PubMed  Google Scholar 

  14. De Torres-Alba F, Kaleschke G, Diller GP et al (2016) Changes in the pacemaker rate after transition from Edwards SAPIEN XT to SAPIEN 3 transcatheter aortic valve implantation: the critical role of valve implantation height. JACC Cardiovasc Interv 9(8):805–813. https://doi.org/10.1016/j.jcin.2015.12.023

    Article  PubMed  Google Scholar 

  15. Kim WK, Mollmann H, Liebetrau C et al (2020) Effectiveness and safety of the ACURATE neo prosthesis in 1,000 patients with aortic stenosis. Am J Cardiol 131:12–16. https://doi.org/10.1016/j.amjcard.2020.05.044

    Article  PubMed  Google Scholar 

  16. C Varc-3 Writing, Genereux P, Piazza N et al (2021) Valve academic research consortium 3: updated endpoint definitions for aortic valve clinical research. Eur Heart J. https://doi.org/10.1093/eurheartj/ehaa799

    Article  Google Scholar 

  17. Rogers T, Greenspun BC, Weissman G et al (2020) Feasibility of coronary access and aortic valve reintervention in low-risk TAVR patients. JACC Cardiovasc Interv 13(6):726–735. https://doi.org/10.1016/j.jcin.2020.01.202

    Article  PubMed  Google Scholar 

  18. Tang GHL, Kaneko T (2018) Assessing implant depth using aortography in transcatheter aortic valve replacement: what you see may not be what you get. JACC Cardiovasc Interv 11(2):129–132. https://doi.org/10.1016/j.jcin.2017.11.004

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We thank Elizabeth Martinson, PhD, from the KHFI Editorial Office for her editorial assistance.

Funding

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Won-Keun Kim.

Ethics declarations

Conflict of interest

WK: proctor, advisory board or speaker honoraria from Boston Scientific, Abbott, Edwards Lifesciences, Medtronic, Meril Life Sciences, Shockwave Med. HN: proctor for Boston Scientific. CH: advisory board Medtronic. All other authors declare that they have no relevant conflict of interests to disclose.

Ethics approval

The study was approved by the ethics committee of the Justus-Liebig University of Gießen.

Consent to participate

Not applicable.

Consent for publication

Not applicable.

Supplementary Information

Below is the link to the electronic supplementary material.

Supplementary file1 (DOCX 169 KB)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kim, WK., Renker, M., Doerr, O. et al. Impact of implantation depth on outcomes of new-generation balloon-expandable transcatheter heart valves. Clin Res Cardiol 110, 1983–1992 (2021). https://doi.org/10.1007/s00392-021-01932-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00392-021-01932-w

Keywords

Navigation