To read this content please select one of the options below:

A review of previous studies on dam leakage based on distributed optical fiber thermal monitoring technology

Xiao Fang (MOE Key Laboratory of Deep Earth Science and Engineering, College of Architecture and Environment, Sichuan University, Chengdu, China)
Yajie Zeng (College of Architecture and Environment, Sichuan University, Chengdu, China)
Feng Xiong (MOE Key Laboratory of Deep Earth Science and Engineering, College of Architecture and Environment, Sichuan University, Chengdu, China)
Jiang Chen (MOE Key Laboratory of Deep Earth Science and Engineering, College of Architecture and Environment, Sichuan University, Chengdu, China)
Fei Cheng (College of Biomass Science and Engineering, Sichuan University, Chengdu, China)

Sensor Review

ISSN: 0260-2288

Article publication date: 23 August 2021

Issue publication date: 13 October 2021

332

Abstract

Purpose

Seepage of the dam is an important safety problem, which may cause internal erosion of the structure. In the field of seepage monitoring in civil engineering, the distributed optical fiber sensing technology based on the temperature tracing method has been paid more attention due to its unique advantages of high sensitivity, good stability and high resolution. The purpose of this paper is to make a review of the existing related research, so as to facilitate the later scholars to understand and further study more systematically.

Design/methodology/approach

In this paper, three kinds of commonly used distributed fiber temperature measurement technologies are introduced. Based on the working principle, monitoring system, theoretical analysis, experimental research and engineering application of the fiber seepage monitoring technology, the present situation of dam seepage monitoring based on distributed fiber is reviewed in detail and their advantages and disadvantages are compared.

Findings

The thermal monitoring technology of seepage measurement depends on the accuracy of optical fiber temperature measurement (including the accuracy of the system and the rationality of the discrimination method), the correct installation of optical fiber and the quantitative analysis of temperature data. The accuracy of the current monitoring system can basically meet the existing measurement requirements, but the correct installation of optical fiber and the calibration of temperature data need to be further studied for different discrimination methods, and this field has great research value.

Originality/value

At present, there are many applications and research studies of optical fiber sensing in the field of structural health monitoring, and there are also reviews of related aspects. However, there is little or no review only in the field of seepage monitoring. This paper summarizes the research and application of optical fiber sensing in the field of seepage monitoring. The possibility of the gradient method to find its new prospect with the development of monitoring systems and the improvement of temperature resolution is discussed. The idea of extending the seepage monitoring method based on distributed optical fiber thermal monitoring technology to other monitoring fields is also given in the paper.

Keywords

Acknowledgements

National Natural Science Foundation of China.

51509174.

Citation

Fang, X., Zeng, Y., Xiong, F., Chen, J. and Cheng, F. (2021), "A review of previous studies on dam leakage based on distributed optical fiber thermal monitoring technology", Sensor Review, Vol. 41 No. 4, pp. 350-360. https://doi.org/10.1108/SR-02-2021-0068

Publisher

:

Emerald Publishing Limited

Copyright © 2021, Emerald Publishing Limited

Related articles