Transient analysis of grounding electrodes in a two-layer soil considering frequency dependence of soil

  • Original Paper
  • Published:
Electrical Engineering Aims and scope Submit manuscript

Abstract

In lightning discharge, the grounding systems' transient behavior is influenced by frequency-dependent effects. These effects are related to complex phenomena arising from the fast rise time of the impulse current. In this paper, a new frequency-dependent (FD) model of grounding systems (GSs) is presented that can be deployed in time-domain analysis. The proposed wideband modeling considers the frequency dependence of the soil electrical parameters (conductivity and relative permittivity). This model is sufficiently accurate for single-port and multi-port GSs buried in uniform and non-uniform soil in the frequency range of lightning. The main innovation of the proposed model is that it can be implemented in the time domain without requiring the inversion of the GS impedance matrix. Hence, this method is less complex than conventional approaches. As one of its applications, the effect of FD modeling of GS is investigated on the lightning overvoltages of a wind farm. The simulation results show that the frequency dependence of soil has a huge impact on overvoltage magnitude and the energy absorption of surge arresters (SAs) in wind farms; this effect varies according to the type of the GS and the soil resistivity, so it is of great importance from technical and economical points of view.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

Availability of data and material

If it was necessary, all data, materials and codes are available.

References

  1. Slama ME, Beroual A (2021) Flashover discharges dynamic with continuous and discontinuous pollution layer under lightning impulse stress. Electr Eng 12:1–9

    Google Scholar 

  2. Gouda OE, El-Saied T, Salem WA, Khater AM (2019) Evaluations of the apparent soil resistivity and the reflection factor effects on the grounding grid performance in three-layer soils. IET Sci Meas Technol 13(4):572–581. https://doi.org/10.1049/iet-smt.2018.5336

    Article  Google Scholar 

  3. Chiheb S, Kherif O, Teguar M, Mekhaldi A, Harid N (2018) Transient behaviour of grounding electrodes in uniform and in vertically stratified soil using state space representation. IET Sci Meas Technol 12(4):427–435. https://doi.org/10.1049/iet-smt.2017.0310

    Article  Google Scholar 

  4. Nixon KJ, Jandrell IR, Phillips AJ (2006) A simplified model of the lightning performance of a driven rod earth electrode in multi-layer soil that includes the effect of soil ionisation. Conf Record of the IEEE Ind Appl Conf Forty-First IAS Ann Meet. https://doi.org/10.1109/IAS.2006.256783

    Article  Google Scholar 

  5. Cao X, Li R, Tao X, Yang X, Sun X, Han H (2021) Lightning flashover characteristics of metro viaduct section with contact rail power supply system. Electr Eng 103(2):983–991

    Article  Google Scholar 

  6. Nematollahi AF, Vahidi B (2021) The effect of the inclined lightning channel on electromagnetic fields and the induced voltages on overhead lines. Electr Eng. https://doi.org/10.1007/s00202-021-01304-7

    Article  Google Scholar 

  7. Garolera AC, Cummins KL, Madsen SF, Holboell J, Myers JD (2015) Multiple lightning discharges in wind turbines associated with nearby cloud-to-ground lightning. IEEE Trans Sustain Energy 6(2):526–533. https://doi.org/10.1109/tste.2015.2391013

    Article  Google Scholar 

  8. Malcolm N, Aggarwal R (2016) The significance of median natural lightning current strokes on the energy handling capabilities of surge arresters employed in wind farms. Renew Energy 85:319–326. https://doi.org/10.1016/j.renene.2015.06.055

    Article  Google Scholar 

  9. Malcolm N, Aggarwal RK (2015) The impact of multiple lightning strokes on the energy absorbed by MOV surge arresters in wind farms during direct lightning strikes. Renew Energy 83:1305–1314. https://doi.org/10.1016/j.renene.2015.05.010

    Article  Google Scholar 

  10. Mohammed Z, Hizam H, Gomes C (2019) Lightning-induced transient effects in a hybrid PV–wind system and mitigation strategies. Electric Power Syst Res 174:105882. https://doi.org/10.1016/j.epsr.2019.105882

    Article  Google Scholar 

  11. Tao S, Zhang X, Wang Y, Yang J (2018) Transient behavior analysis of offshore wind turbines during lightning strike to multi-blade. IEEE Access 6:22070–22083. https://doi.org/10.1109/access.2018.2828043

    Article  Google Scholar 

  12. Li W, Xiang N, Bian K, Zhang S, Sun T, Wang Q, Zhu D (2020) Transient characteristics of wind turbine grounding system in high soil resistivity area due to lightning strike. IEEE Int Conf High Voltage Eng Appl ICHVE. https://doi.org/10.1109/ICHVE49031.2020.9279758

    Article  Google Scholar 

  13. Alemi MR, Sheshyekani K (2015) Wide-band modeling of tower-footing grounding systems for the evaluation of lightning performance of transmission lines. IEEE Trans Electromagn Compat 57(6):1627–1636. https://doi.org/10.1109/temc.2015.2453512

    Article  Google Scholar 

  14. Gustavsen B, Semlyen A (1999) Rational approximation of frequency domain responses by vector fitting. IEEE Trans Power Deliv 14(3):1052–1061. https://doi.org/10.1109/61.772353

    Article  Google Scholar 

  15. Gustavsen B (2016) Eliminating measurement cable effects from transformer admittance measurements. IEEE Trans Power Delivery 31(4):1609–1617. https://doi.org/10.1109/tpwrd.2016.2536704

    Article  Google Scholar 

  16. Shariatinasab R, Gholinezhad J, Sheshyekani K, Alemi MR (2016) The effect of wide band modeling of tower-footing grounding system on the lightning performance of transmission lines: a probabilistic evaluation. Electric Power Syst Res 141:1–10. https://doi.org/10.1016/j.epsr.2016.06.040

    Article  Google Scholar 

  17. Heidler F, Cvetic J, Stanic B (1999) Calculation of lightning current parameters. IEEE Trans Power Delivery 14(2):399–404. https://doi.org/10.1109/61.754080

    Article  Google Scholar 

  18. Harid N, Griffiths H, Mousa S, Clark D, Robson S, Haddad A (2015) On the analysis of impulse test results on grounding systems. IEEE Trans Ind Appl 51(6):5324–5334. https://doi.org/10.1109/tia.2015.2442517

    Article  Google Scholar 

  19. Sarajčev P, Goić R (2010) An EMTP model for lightning surge analysis of wind farm. Int Rev Modell Simul (IREMOS) 3(1):70–81

    Google Scholar 

  20. Jiang JL, Chang HC, Kuo CC, Huang CK (2013) Transient overvoltage phenomena on the control system of wind turbines due to lightning strike. Renew Energy 57:181–189. https://doi.org/10.1016/j.renene.2013.01.020

    Article  Google Scholar 

  21. IEEE Lightning and Insulator Subcommittee of the T&D Committee (2005) Parameters of lightning strokes: a review. IEEE Trans Power Deliv 20(1):346–358

    Google Scholar 

  22. Longmire C.L, Smith K.S (1975) A universal impedance for soils. MISSION RESEARCH CORP SANTA BARBARA CA.

  23. Martinez J, Durbak D (2005) Parameter determination for modeling systems transients-part v: surge arresters IEEE PES task force on data for modeling system transients of ieee pes working group on modeling and analysis of system transients using digital simulation (General Systems Subcommittee). IEEE Trans Power Deliv 20(3):2073–2078. https://doi.org/10.1109/tpwrd.2005.848771

    Article  Google Scholar 

Download references

Acknowledgements

The authors are grateful to Dr. J. Gholinezhad, Polytechnique Montréal, Canada, who provided some useful comments.

Funding

No funding was received for conducting this study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Reza Ghanizadeh.

Ethics declarations

Conflict of interest

This article is taken from a doctoral thesis of Author A (Ali Mehri). The authors have no financial or proprietary interests in any material discussed in this article.

Ethics approval

All authors confirm that this work is original and has not been published elsewhere nor is it currently under consideration for publication elsewhere. The data included in this manuscript have not been published previously and are not under consideration by any other journal.

Consent to participate and Publication

All authors are satisfied to participate and publish this article in Electrical Engineering Journal.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Mehri, A., Ghanizadeh, R. & Beiraghi, M. Transient analysis of grounding electrodes in a two-layer soil considering frequency dependence of soil. Electr Eng 104, 1019–1028 (2022). https://doi.org/10.1007/s00202-021-01362-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00202-021-01362-x

Keywords

Navigation