Skip to main content

Advertisement

Log in

A Framework for Vibration Attenuation in Traffic Mast Arm Structures under Wind Loads

  • Research paper
  • Published:
Experimental Techniques Aims and scope Submit manuscript

Abstract

Traffic signals and information signs play a vivid role in maintaining safe travel by guiding drivers on highways and urban roads. Traffic mast arm structures are susceptible to vibrations induced by wind loads. Fatigue-induced failure is common in these structures. However, it is crucial to ascertain the functionality of signal support structures. This paper lays the foundation for a fully computational framework to model and mitigate wind-induced vibrations in traffic lighting support structures by conducting computational fluid dynamics (CFD) simulations, dynamic modeling, and damping enhancement. We validated the CFD simulations by aerodynamic testing. The dependence of flow pattern and aerodynamic loads on Reynolds number reveals the importance of full-scale CFD with large eddy simulation for wind load estimation on mast arm structures. Distributed tuned mass dampers were created by employing available weights of lighting boxes. The results show that distributed tuned lighting boxes are effective for vibration suppression. Besides, damping enhancement can significantly reduce vibration-induced stresses and hence extend the fatigue life. The proposed mitigation technique promises to save construction costs and improve the safety of the traveling public. The procedure followed for creating time histories of wind loads integrated with finite element modeling applies to other vibration lessening techniques for potential inclusion in the AASHTO standard.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
Fig. 20
Fig. 21
Fig. 22

Similar content being viewed by others

References

  1. Dexter R, Ricker M (2002) Fatigue-resistant Design of Cantilevered Signal, sign, and light supports. National Academy Press, TRB, Washington, DC, United States http://www.trb.org/trb/bookstore

  2. Caetano E, Silva S, Bateira J (2011) A vision system for vibration monitoring of civil engineering structures. Exp Tech 35:74–82. https://doi.org/10.1111/j.1747-1567.2010.00653.x

    Article  Google Scholar 

  3. Madheswaran CK, Rao GVR (2021) Development of retrofitting technique for seismically vulnerable open ground Storey reinforced concrete buildings. Exp Tech:1–23. https://doi.org/10.1007/s40799-021-00456-2

  4. Zhou Y, Dawood M, Gencturk B (2017) High-cycle fatigue performance of high-mast illumination pole bases with pre-existing cracks. J Constr Steel Res 138:463–472. https://doi.org/10.1016/j.jcsr.2017.07.020

    Article  Google Scholar 

  5. Juozaitis J, Sapalas A (1998) Behaviour of masts subjected to action of wind load. J Constr Steel Res 1:467. https://doi.org/10.1016/s0143-974x(98)80090-4

    Article  Google Scholar 

  6. Cook R, Bloomquist D, Kalajian M, Cannon V (1998) Mechanical damping systems for traffic signal mast arms. Engineering and Industrial Experiment Station, University of Florida, Florida

  7. M.R. Kaczinski, R.J. Dexter, J.P. Van Dien, Fatigue-resistant design of cantilevered signal, sign and light supports, NCHRP Rep. 412, Transportation Research Board, National Research Council, Washington, DC, 1998

  8. Wieghaus KT, Mander JB, Hurlebaus S (2017) Damage avoidance solution to mitigate wind-induced fatigue in steel traffic support structures. J Constr Steel Res 138:298–307. https://doi.org/10.1016/j.jcsr.2017.06.037

    Article  Google Scholar 

  9. Hartnagel B, Barker M (1999) Strain measurements on traffic signal mast arms, in: 1999 Struct. Congr, American Society of Civil Engineers, New Orleans, Louisiana, United States

  10. Chen G, Wu J, Yu J, Dharani L (2001) Fatigue assessment of traffic signal mast arms based on field test data under natural wind gusts. Transp. Res. Rec. J. Transp. Res. Board. 1770:188–194. https://doi.org/10.3141/1770-24

    Article  Google Scholar 

  11. SoleimaniBabakamali MH, Moghadam A, Sarlo R, Hebdon MH, Harvey PS (2021) Mast arm monitoring via traffic camera footage: a pixel-based modal analysis approach. Exp Tech 45:329–343. https://doi.org/10.1007/s40799-020-00422-4

    Article  Google Scholar 

  12. J.R. McDonald, K.C. Mehta, W. Oler, N. Pulipaka, Wind Load Effects on Signs, Luminaires and Traffic Signal Structures, Rrept. No. REPT-1303-F, Federal Highway Administration, Austin, 1995. https://trid.trb.org/view.aspx?id=421710

  13. Magdaleno A, Pereira E, Reynolds P, Lorenzana A (2021) A common framework for tuned and active mass dampers: application to a two-Storey building model. Exp Tech:1–11. https://doi.org/10.1007/s40799-020-00432-2

  14. Latour M, Piluso V, Rizzano G (2018) Experimental analysis of beam-to-column joints equipped with sprayed aluminium friction dampers. J Constr Steel Res 146:33–48. https://doi.org/10.1016/j.jcsr.2018.03.014

    Article  Google Scholar 

  15. Monir HS, Zeynali K (2013) A modified friction damper for diagonal bracing of structures. J Constr Steel Res 87:17–30. https://doi.org/10.1016/j.jcsr.2013.04.004

    Article  Google Scholar 

  16. Hamilton H, Riggs GS, Puckett JA, Hamilton HR III, Riggs GS, Puckett JA (2000) Increased damping in cantilevered traffic signal structures. J Struct Eng 126:530–537. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:4(530)

    Article  Google Scholar 

  17. Behbahani HP, Bin Adnan A, Vafaei M, Shad H, Pheng OP (2017) Vibration mitigation of structures through TLCD with embedded baffles. Exp Tech 41:139–151. https://doi.org/10.1007/s40799-016-0163-0

    Article  Google Scholar 

  18. Cook RA, Bloomquist D, Richard DS, Kalajian MA (2001) Damping of cantilevered traffic signal structures. J Struct Eng 127:1476–1483. https://doi.org/10.1061/(ASCE)0733-9445(2001)127:12(1476)

    Article  Google Scholar 

  19. McManus PS, Hamilton HR III, Puckett JA (2003) Damping in cantilevered traffic signal structures under forced vibration. J Struct Eng 129:373–382. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:3(373)

    Article  Google Scholar 

  20. R. Christenson, Reducing fatigue in wind-excited traffic signal support structures using smart damping technologies, NCHRP IDEA project 141, Transportation Research Board, 2011. https://trid.trb.org/view.aspx?id=1116320

  21. Christenson R, Cashany M, Hua J, Zuo D (2014) Field testing of signal head vibration absorber to reduce fatigue in wind-excited traffic signal support structures. Transp Res Rec J Transp Res Board 2406:42–48. https://doi.org/10.3141/2406-05

    Article  Google Scholar 

  22. Smith J (1988) Vibration of structures: applications in civil engineering design. Spon Press, New York

  23. Cook RA, Bloomquist D, Richard DS, Kalajian MA, Cannon VA, Arnold DP (2000) Design, testing, and specification of a mechanical damping device for mast arm traffic signal structures. University of Florida Engineering and Industrial Experiment Station

  24. V. Kolousek, Wind effects on civil engineering structures (studies in wind engineering and industrial aerodynamics), Elsevier Science Ltd, 1984

  25. P. Sachs, Wind Forces in Engineering, 2nd ed., Elsevier Ltd., 1978. https://doi.org/10.1016/C2013-0-02839-3

  26. AASНТО (2013) Standard specifications for structural supports for highway signs, luminaires and traffic signals, 6th edn. AASHTO Subcommittee on Bridges and Structures, American Association of State Highway and Transportation Officials, Washington, DC, United States

  27. B.M. Creamer, K.H. Frank, R.E. Klingner, Fatigue Loading of Cantilever Sign Structures from Truck Wind Gusts, Report No. FHWA/TX- 79/10+209-1F, Center for Highway Research, University of Texas at Austin, 1979

  28. R. Cook, D. Bloomquist, A. Agosta, K. Taylor, Wind load data for variable message signs, Florida Department of Transportation, 1996

  29. Li S, Liang J, Zheng S, Jiang N, Liu L, Guo P (2019) A novel test method for aerodynamic coefficient measurements of structures using wind generated by a moving vehicle. Exp Tech 43:677–693

    Article  CAS  Google Scholar 

  30. Zuo D, Letchford CW (2010) Wind-induced vibration of a traffic-signal-support structure with cantilevered tapered circular mast arm. Eng Struct 32:3171–3179. https://doi.org/10.1016/j.engstruct.2010.06.005

    Article  Google Scholar 

  31. Gjerek B, Drazumeric R, Kosel F (2014) A novel experimental setup for multiparameter aeroelastic wind tunnel tests. Exp Tech 38:30–43. https://doi.org/10.1111/j.1747-1567.2012.00839.x

    Article  Google Scholar 

  32. OpenFOAM, OpenFOAM: User Guide, OpenCFD Ltd. (2012). https://www.openfoam.com/documentation/guides/latest/doc/

  33. A. Jackson, A Comprehensive Tour of snappyHexMesh, 7th OpenFOAM Work. 25 June 2012. (2017)

  34. Spalart P, Deck S, Shur M, Squires K, Strelets M, Travin A (2006) A new version of detached-eddy simulation, resistant to ambiguous grid densities. 20:181–195. https://doi.org/10.1007/s00162-006-0015-0

  35. Smagorinsky J (1963) General circulation experiments with the primitive equations: I. the basic experiment. Mon Weather Rev 91:99–164. https://doi.org/10.1175/1520-0493(1963)091<0099:GCEWTP>2.3.CO;2

  36. A.M. Aly, H. Gol Zaroudi, M. Rezaee, Hurricane Hazard Mitigation in Traffic Light Support Structures, Rep. No. FHWA/LA.15/14-2TIRE, LTRC Project Number: 14-2TIRE, 2016. http://www.ltrc.lsu.edu/pdf/2016/14-2TIRE.pdf

  37. ANSYS Inc. (2020) ANSYS Fluent User’s Guide. Canonsburg, PA, USA

  38. Holmes JD, Bekele S (2021) Wind loading of structures, 4th edn. CRC Press, Boca Raton

  39. Mathey F, Cokljat D, Bertoglio J (2006) Specification of LES inlet boundary condition using vortex method. Prog Comput Fluid Dyn 6:58–67. https://doi.org/10.1504/PCFD.2006.009483

    Article  Google Scholar 

  40. Mathey F, Cokljat D, Bertoglio JP, Sergent E (2006) Assessment of the vortex method for large eddy simulation inlet conditions. Prog Comput Fluid Dyn An Int J 6:58–67. https://doi.org/10.1504/PCFD.2006.009483

    Article  Google Scholar 

  41. Aly AM, Gol Zaroudi H (2020) Peak pressures on low rise buildings: CFD with LES versus full scale and wind tunnel measurements. Wind Struct. 30:99–117. https://doi.org/10.12989/was.2020.30.1.099

    Article  Google Scholar 

  42. Král R, Pospíšil S, Náprstek J (2016) Experimental set-up for advanced aeroelastic tests on sectional models. Exp Tech 40:3–13. https://doi.org/10.1007/s40799-015-0004-6

    Article  Google Scholar 

  43. Gol Zaroudi H, Aly AM (2017) Open-jet boundary-layer processes for aerodynamic testing of low-rise buildings. Wind Struct. 25:233–259. https://doi.org/10.12989/was.2017.25.3.233

    Article  Google Scholar 

  44. Aly AM, Gol-Zaroudi H (2017) Atmospheric boundary layer simulation in a new open-jet facility at LSU: CFD and experimental investigations. Measurement. 110:121–133. https://doi.org/10.1016/j.measurement.2017.06.027

    Article  Google Scholar 

  45. Scanivalve, Intelligent Pressure and Temperature Instrumentation, (2021). https://scanivalve.com/#http://scanivalve.com/about-us/

  46. Aly AM (2013) Proposed approach for determination of tributary areas for scattered pressure taps. Wind Struct. An Int. J. 16. https://doi.org/10.12989/was.2013.16.6.617

  47. Pyrkosz M, Van Karsen C (2013) Comparative modal tests of a violin. Exp Tech 37:47–62. https://doi.org/10.1111/j.1747-1567.2012.00831.x

    Article  Google Scholar 

  48. Rezaee M, Aly AM (2016) Vibration control in wind turbines for performance enhancement: A comparative study. Wind Struct. 22:107–131. https://doi.org/10.12989/was.2016.22.1.107

    Article  Google Scholar 

  49. Aly AM, Zasso A, Resta F (2011) Dynamics and control of high-rise buildings under multidirectional wind loads. Smart Mater Res 2011:1–15. https://doi.org/10.1155/2011/549621

    Article  Google Scholar 

  50. Feng MQ, Mita A (1995) Vibration control of tall buildings using mega subconfiguration. J Eng Mech 121:1082–1088. https://doi.org/10.1061/(ASCE)0733-9399(1997)123:6(650)

    Article  Google Scholar 

  51. Aly AM (2014) Proposed robust tuned mass damper for response mitigation in buildings exposed to multidirectional wind. Struct Des Tall Spec Build 23:664–691. https://doi.org/10.1002/tal.1068

    Article  Google Scholar 

  52. Belloni F, Eder MA, Cherrier B (2018) An improved sub-component fatigue testing method for material characterization. Exp Tech 42:533–550. https://doi.org/10.1007/s40799-018-0264-z

    Article  Google Scholar 

  53. Chapain S, Aly AM (2019) Vibration attenuation in high-rise buildings to achieve system-level performance under multiple hazards. Eng Struct 197:109352. https://doi.org/10.1016/j.engstruct.2019.109352

    Article  Google Scholar 

  54. Chapain S, Aly AM (2021) Vibration attenuation in wind turbines: A proposed robust pendulum pounding TMD. Eng. Struct. 233. https://doi.org/10.1016/j.engstruct.2021.111891

  55. Rezaee M, Aly AM (2019) Proposed theory of Semiactive gains for smart dampers in MDOF systems. J Struct Eng 145:04019155. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002453

    Article  Google Scholar 

  56. Aly AM, Zasso A, Resta F (2011) On the dynamics of a very slender building under winds: Response reduction using MR dampers with lever mechanism. Struct. Des. Tall Spec. Build 20. https://doi.org/10.1002/tal.647

Download references

Acknowledgments

The first author would like to acknowledge the funding support for this research by the Louisiana Department of Transportation and Development (DOTD) through the Louisiana Transportation Research Center (LTRC) (contract number: 14-2TIRE). The discussion with Dr. Walid Alaywan is acknowledged with thanks. The study used the LSU High-Performance Computing (HPC) facilities. The findings and conclusions are those of the authors and do not necessarily represent the official position of the sponsors.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. M. Aly.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Aly, A., Gol-Zaroudi, H. & Rezaee, M. A Framework for Vibration Attenuation in Traffic Mast Arm Structures under Wind Loads. Exp Tech 46, 575–593 (2022). https://doi.org/10.1007/s40799-021-00495-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s40799-021-00495-9

Keywords

Navigation