Real-time venography-guided extrathoracic puncture technique for cardiovascular implantable electronic device implantation

  • Original Article
  • Published:
Heart and Vessels Aims and scope Submit manuscript

Abstract

Central venous access is an essential technique for cardiovascular implantable electronic device (CIED) implantation, and the use of axillary vein approach has recently been increasing. This study sought to examine whether real-time venography-guided extrathoracic puncture facilitates the procedure. We retrospectively analyzed 179 consecutive patients who underwent CIED implantation using the axillary vein puncture method. Patients were divided into two groups: the conventional method group (CG, n = 107) and the real-time venography-guided group (RG, n = 82). The application of real-time venography was at the discretion of individual operators. Operators with experience of less than 50 CIED implantations were defined as inexperienced operators in this study. Puncture duration and number of attempts were significantly less in the RG group than in the CG group (283 ± 198 vs. 421 ± 361 s, p < 0.01, and 3.19 ± 2.00 vs. 4.18 ± 2.85, p < 0.01). These benefits of real-time venography were observed in inexperienced operators, but not in experienced operators. In addition, the success rate without extra attempts at puncture was higher in the RG group (54% vs. 32%, p < 0.01). Although the total amount of contrast medium was higher in the RG group (16.3 ± 4.1 mL vs. 11.9 ± 6.6 mL, p < 0.01), serum levels of creatinine pre- and post-operation were not different in the two groups (p = NS). We concluded that real-time venography is a safe and effective method for axillary vein puncture, especially in inexperienced operators.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Chan NY, Kwong NP, Cheong AP (2017) Venous access and long-term pacemaker lead failure: comparing contrast-guided axillary vein puncture with subclavian puncture and cephalic cutdown. Europace 19:1193–1197

    Article  Google Scholar 

  2. Shimada H, Hoshino K, Yuki M, Sakurai S, Owa M (1999) Percutaneous cephalic vein approach for permanent pacemaker implantation. Pacing Clin Electrophysiol 22:1499–1501

    Article  CAS  Google Scholar 

  3. Ramza BM, Rosenthal L, Hui R, Nsah E, Savader S, Lawrence JH, Tomaselli G, Berger R, Brinker J, Calkins H (1997) Safety and effectiveness of placement of pacemaker and defibrillator leads in the axillary vein guided by contrast venography. Am J Cardiol 80:892–896

    Article  CAS  Google Scholar 

  4. Parsonnet V, Bernstein AD, Lindsay B (1989) Pacemaker-implantation complication rates: an analysis of some contributing factors. J Am Coll Cardiol 13:917–921

    Article  CAS  Google Scholar 

  5. Kirkfeldt RE, Johansen JB, Nohr EA, Moller M, Arnsbo P, Nielsen JC (2012) Pneumothorax in cardiac pacing: a population-based cohort study of 28,860 Danish patients. Europace 14:1132–1138

    Article  Google Scholar 

  6. Magney JE, Flynn DM, Parsons JA, Staplin DH, Chin-Purcell MV, Milstein S, Hunter DW (1993) Anatomical mechanisms explaining damage to pacemaker leads, defibrillator leads, and failure of central venous catheters adjacent to the sternoclavicular joint. Pacing Clin Electrophysiol 16:445–457

    Article  CAS  Google Scholar 

  7. Calkins H, Ramza BM, Brinker J, Atiga W, Donahue K, Nsah E, Taylor E, Halperin H, Lawrence JH, Tomaselli G, Berger RD (2001) Prospective randomized comparison of the safety and effectiveness of placement of endocardial pacemaker and defibrillator leads using the extrathoracic subclavian vein guided by contrast venography versus the cephalic approach. Pacing Clin Electrophysiol 24:456–464

    Article  CAS  Google Scholar 

  8. Tse HF, Lau CP, Leung SK (2001) A cephalic vein cutdown and venography technique to facilitate pacemaker and defibrillator lead implantation. Pacing Clin Electrophysiol 24:469–473

    Article  CAS  Google Scholar 

  9. Beig JR, Ganai BA, Alai MS, Lone AA, Hafeez I, Dar MI, Tramboo NA, Rather HA (2018) Contrast venography vs. microwire assisted axillary venipuncture for cardiovascular implantable electronic device implantation. Europace 20:1318–1323

    Article  Google Scholar 

  10. Al Fagih A, Ahmed A, Al Hebaishi Y, El Tayeb A, Dagriri K, Al Ghamdi S (2015) An initiative technique to facilitate axillary vein puncture during CRT implantation. J Invasive Cardiol 27:341–343

    PubMed  Google Scholar 

  11. Sawasaki K, Sato T, Takayama Y, Yokota S, Morita Y, Kobayashi M, Saito M, Takanaka C, Muto M (2012) Novel extrathoracic puncture techniques for pacemaker lead insertion: pitfalls of the conventional extrathoracic puncture method. J Arrhythmia 28:111–113

    Article  Google Scholar 

  12. Antonelli D, Feldman A, Freedberg NA, Turgeman Y (2013) Axillary vein puncture without contrast venography for pacemaker and defibrillator leads implantation. Pacing Clin Electrophysiol 36:1107–1110

    Article  Google Scholar 

  13. Yang F, Kulbak G (2015) A new trick to a routine procedure: taking the fear out of the axillary vein stick using the 35° caudal view. Europace 17:1157–1160

    Article  Google Scholar 

  14. Orihashi K, Imai K, Sato K, Hamamoto M, Okada K, Sueda T (2005) Extrathoracic subclavian venipuncture under ultrasound guidance. Circ J 69:1111–1115

    Article  Google Scholar 

  15. Esmaiel A, Hassan J, Blenkhorn F, Mardigyan V (2016) The use of ultrasound to improve axillary vein access and minimize complications during pacemaker implantation. Pacing Clin Electrophysiol 39:478–482

    Article  Google Scholar 

  16. Franco E, Rodriguez Muñoz D, Matía R, Hernandez-Madrid A, Carbonell San Román A, Sánchez I, Zamorano J, Moreno J (2016) Wireless ultrasound-guided axillary vein cannulation for the implantation of cardiovascular implantable electric devices. J Cardiovasc Electrophysiol 27:482–487

    Article  Google Scholar 

  17. Migliore F, Fais L, Vio R, De Lazzari M, Zorzi A, Bertaglia E, Iliceto S (2020) Axillary vein access for permanent pacemaker and implantable cardioverter defibrillator implantation: Fluoroscopy compared to ultrasound. Pacing Clin Electrophysiol 43:566–572

    Article  Google Scholar 

  18. Murarka S, Movahed MR (2014) The use of micropuncture technique for vascular or body cavity access. Rev Cardiovasc Med 15:245–251

    PubMed  Google Scholar 

  19. Liu Y, Chen JY, Tan N, Zhou YL, Yu DQ, Chen ZJ, He YT, Liu YH, Luo JF, Huang WH, Li G, He PC, Yang JQ, Xie NJ, Liu XQ, Yang DH, Huang SJ, Piao-Ye LHL, Ran P, Duan CY, Chen PY (2015) Safe limits of contrast vary with hydration volume for prevention of contrast-induced nephropathyafter coronary angiography among patients with a relatively low risk of contrast-induced nephropathy. Circ Cardiovasc Interv 8:e001859

    Article  Google Scholar 

  20. Maliborski A, Zukowski P, Nowicki G, Bogusławska R (2011) Contrast-induced nephropathy – a review of current literature and guidelines. Med Sci Monit 17:199–204

    Article  Google Scholar 

Download references

Funding

This work was supported in part by JSPS KAKENHI Grant Numbers 17K16021 and 20K08406.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Manabu Kashiwagi.

Ethics declarations

Conflict of interest

There are no conflicts of interest in this study.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Below is the link to the electronic supplementary material.

Supplementary file1 (DOCX 199 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kashiwagi, M., Katayama, Y., Kuroi, A. et al. Real-time venography-guided extrathoracic puncture technique for cardiovascular implantable electronic device implantation. Heart Vessels 37, 91–98 (2022). https://doi.org/10.1007/s00380-021-01885-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00380-021-01885-0

Keywords

Navigation