Skip to main content
Log in

Direct shear behavior after elevated temperature exposure of epoxy-coated carbon textile-reinforced mortar (TRM) modified with different types of microfibers

  • Original Article
  • Published:
Materials and Structures Aims and scope Submit manuscript

Abstract

In this study, direct shear behavior after exposure to high temperatures of epoxy-coated carbon textile-reinforced mortar (TRM) modified with different types of microfibers was investigated. Three primary test parameters were examined: elevated temperature levels (200°, 250°, and 300 °C); different microfiber types (polyvinyl alcohol (PVA) fibers, steel fibers, amorphous metallic (AM) fibers, and hybrid fibers made up of steel and PVA fibers); and heating time periods (2 and 4 h). In total, 88 direct shear test specimens were manufactured and tested. The direct shear tests were performed based on the FIP standard by employing test specimens with a pre-formed notch around the vertical middle plane. From the test results, it was observed that elevated temperatures significantly affected bond performance between the textile reinforcement and the mortar matrix, leading to degradation in shear mechanical properties of the test specimens. Under ambient temperature, the addition of microfibers to the mortar matrix was beneficial to most shear mechanical properties of TRM specimens, compared with TRM specimens without microfibers. However, the benefits of PVA fibers were significantly diminished at elevated temperatures of 200–300 °C, while AM or steel fibers adequately maintained benefits at the same temperatures. Heating periods investigated in this study did not significantly affect the shear behavior of the TRM specimens. In addition, an analytical model to predict the ultimate shear stress of TRM specimens with and without microfibers (steel or AM fibers) was proposed, and the prediction results agree with the experimental results.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14

Similar content being viewed by others

References

  1. Triantafillou T, Papanicolaou CCG (2013) Innovative applications of textile-based composites in strengthening and seismic retrofitting as well as in the prefabrication of new structures. Advanced Materials Research 639:26–41

    Article  Google Scholar 

  2. Triantafillou TC (1998) Composites: a new possibility for the shear strengthening of concrete, masonry and wood. Compos Sci Technol 58(8):1285–1295

    Article  Google Scholar 

  3. Angelillo M, Babilio E, Cardamone L, Fortunato A, Lippiello M (2014) Some remarks on the retrofitting of masonry structures with composite materials. Compos B Eng 61:11–16

    Article  Google Scholar 

  4. Rempel S, Hegger J (2015) Slender facade structures made of textile-reinforced high-performance concrete. In: 11th International symposium on ferrocement FERRO-11 in connection with the 3rd ICTRC, pp 7–10

  5. Ehlig D, Schladitz F, Frenzel M, Curbach M (2012) Textilbeton-Ausgeführte Projekte im Überblick. Beton-und Stahlbetonbau 107(11):777–785

    Article  Google Scholar 

  6. Liebolt M, Butler M, Mechtcherine V (2008) Application of textile reinforced concrete in prefabrication. In: BEFIB 2008: 7th RILEM international symposium on fibre reinforced concrete, pp 253–262

  7. Curbach M, Jesse D, Weiland S (2006) The first textile reinforced segment bridge from the idea to the construction. Betonwerk Und Fertigteiltechnik 72(2):54

    Google Scholar 

  8. Triantafillou T (ed) (2016) Textile fibre composites in civil engineering. Woodhead Publishing

  9. D’Ambrisi A, Focacci F (2011) Flexural strengthening of RC beams with cement-based composites. J Compos Constr 15(5):707–720

    Article  Google Scholar 

  10. Tetta ZC, Koutas LN, Bournas DA (2015) Textile-reinforced mortar (TRM) versus fiber-reinforced polymers (FRP) in shear strengthening of concrete beams. Compos B Eng 77:338–348

    Article  Google Scholar 

  11. Triantafillou TC, Papanicolaou CG (2006) Shear strengthening of reinforced concrete members with textile reinforced mortar (TRM) jackets. Mater Struct 39(1):93–103

    Article  Google Scholar 

  12. Koutas L, Bousias SN, Triantafillou TC (2015) Seismic strengthening of masonry-infilled RC frames with TRM: experimental study. J Compos Constr 19(2):04014048

    Article  Google Scholar 

  13. Triantafillou TC (2007) Textile-reinforced mortars (TRM) versus fibre-reinforced polymers (FRP) as strengthening and seismic retrofitting materials for reinforced concrete and masonry structures. In: International conference for advanced composites in construction (ACIC07)

  14. Dinh NH, Park SH, Choi KK (2020) Tensile characteristics of carbon fiber-textile reinforced mortar with aluminum oxide treated anchorage surfaces. Adv Compos Mater 29(5):509–527

    Article  Google Scholar 

  15. Dinh NH, Park SH, Choi KK (2020) Seismic performance of reinforced concrete columns retrofitted by textile-reinforced mortar jackets. Struct Infrastruct Eng 16(10):1364–1381

    Article  Google Scholar 

  16. Donnini J, Corinaldesi V, Nanni A (2016) Mechanical properties of FRCM using carbon fabrics with different coating treatments. Compos B Eng 88:220–228

    Article  Google Scholar 

  17. Messori M, Nobili A, Signorini C, Sola A (2019) Effect of high temperature exposure on epoxy-coated glass textile reinforced mortar (GTRM) composites. Constr Build Mater 212:765–774

    Article  Google Scholar 

  18. Rambo DAS, de Andrade Silva F, Toledo Filho RD, Gomes ODFM (2015) Effect of elevated temperatures on the mechanical behavior of basalt textile reinforced refractory concrete. Mater Des 65:24–33

    Article  Google Scholar 

  19. de Andrade Silva F, Butler M, Hempel S, Toledo Filho RD, Mechtcherine V (2014) Effects of elevated temperatures on the interface properties of carbon textile-reinforced concrete. Cement Concr Compos 48:26–34

    Article  Google Scholar 

  20. Chan YN, Peng GF, Anson M (1999) Residual strength and pore structure of high-strength concrete and normal strength concrete after exposure to high temperatures. Cement Concr Compos 21(1):23–27

    Article  Google Scholar 

  21. Xiao J, Falkner H (2006) On residual strength of high-performance concrete with and without polypropylene fibres at elevated temperatures. Fire Saf J 41(2):115–121

    Article  Google Scholar 

  22. Li M, Qian C, Sun W (2004) Mechanical properties of high-strength concrete after fire. Cem Concr Res 34(6):1001–1005

    Article  Google Scholar 

  23. Pliya P, Beaucour AL, Noumowé A (2011) Contribution of cocktail of polypropylene and steel fibres in improving the behaviour of high strength concrete subjected to high temperature. Constr Build Mater 25(4):1926–1934

    Article  Google Scholar 

  24. Lau A, Anson M (2006) Effect of high temperatures on high performance steel fibre reinforced concrete. Cem Concr Res 36(9):1698–1707

    Article  Google Scholar 

  25. Dinh NH, Choi KK, Kim HS (2016) Mechanical properties and modeling of amorphous metallic fiber-reinforced concrete in compression. Int J Conc Struct Mater 10(2):221–236

    Article  Google Scholar 

  26. Choe G, Kim G, Kim H, Hwang E, Lee S, Nam J (2019) Effect of amorphous metallic fiber on mechanical properties of high-strength concrete exposed to high temperature. Constr Build Mater 218:448–456

    Article  Google Scholar 

  27. Sahmaran M, Lachemi M, Li VC (2010) Assessing mechanical properties and microstructure of fire-damaged engineered cementitious composites. ACI Mater J 107(3):297

    Google Scholar 

  28. Won JP, Hong BT, Choi TJ, Lee SJ, Kang JW (2012) Flexural behaviour of amorphous micro-steel fibre-reinforced cement composites. Compos Struct 94(4):1443–1449

    Article  Google Scholar 

  29. Chen B, Liu J (2004) Residual strength of hybrid-fiber-reinforced high-strength concrete after exposure to high temperatures. Cem Concr Res 34(6):1065–1069

    Article  Google Scholar 

  30. Fédération internationale de la précontrainte. Commission on Prefabrication (1982) Shear at the interface of precast and in situ concrete. Fédération internationale de la précontrainte.

  31. ASTM C230 (2014) Standard specification for flow table for use in tests of hydraulic cement. American Society of Testing and Materials, West Conshohocken, PA

  32. ASTM C185 (2015) Standard test method for air content of hydraulic cement mortar. American Society of Testing and Materials, West Conshohocken, PA

  33. Dinh NH, Van Tran H, Choi KK (2020) Direct shear behavior of cementitious mortar reinforced by carbon fiber textile. Constr Build Mater 249:118760

    Article  Google Scholar 

  34. Xu SL, Shen LH, Wang JY, Fu Y (2014) High temperature mechanical performance and micro interfacial adhesive failure of textile reinforced concrete thin-plate. J Zhejiang Univ Sci A 15(1):31–38

    Article  Google Scholar 

  35. Donnini J, y Basalo FDC, Corinaldesi V, Lancioni G, Nanni A (2017) Fabric-reinforced cementitious matrix behavior at high-temperature: Experimental and numerical results. Compos Part B Eng 108:108–121

    Article  Google Scholar 

  36. Trapko T (2013) The effect of high temperature on the performance of CFRP and FRCM confined concrete elements. Compos B Eng 54:138–145

    Article  Google Scholar 

  37. Ombres L (2015) Analysis of the bond between fabric reinforced cementitious mortar (FRCM) strengthening systems and concrete. Compos B Eng 69:418–426

    Article  Google Scholar 

  38. Ombres L (2017) Structural performances of thermally conditioned PBO FRCM confined concrete cylinders. Compos Struct 176:1096–1106

    Article  Google Scholar 

  39. Maroudas SR, Papanicolaou CCG (2017) Effect of high temperatures on the TRM-to-masonry bond. In: Key engineering materials, vol 747. Trans Tech Publications Ltd, pp 533–541

  40. Dinh NH, Park SH, Choi KK (2021) Effect of dispersed micro-fibers on tensile behavior of uncoated carbon textile-reinforced cementitious mortar after high-temperature exposure. Cement Concr Compos 118:103949

    Article  Google Scholar 

  41. Park SH, Dinh NH, Um JW, Choi KK (2021) Experimental study on the seismic performance of RC columns retrofitted by lap-spliced textile-reinforced mortar jackets after high-temperature exposure. Compos Struct 256:113108

    Article  Google Scholar 

  42. Tetta ZC, Bournas DA (2016) TRM vs FRP jacketing in shear strengthening of concrete members subjected to high temperatures. Compos B Eng 106:190–205

    Article  Google Scholar 

  43. Naaman AE (2003) Engineered steel fibers with optimal properties for reinforcement of cement composites. J Adv Concr Technol 1(3):241–252

    Article  Google Scholar 

  44. Huang BT, Wu JQ, Yu J, Dai JG, Leung CK (2020) High-strength seawater sea-sand engineered cementitious composites (SS-ECC): mechanical performance and probabilistic modeling. Cement Concr Compos 114:103740

    Article  Google Scholar 

  45. Zhang D, Yu J, Wu H, Jaworska B, Ellis BR, Li VC (2020) Discontinuous micro-fibers as intrinsic reinforcement for ductile Engineered Cementitious Composites (ECC). Compos Part B Eng 184:107741

    Article  Google Scholar 

  46. Kim H, Kim G, Lee S, Choe G, Nam J, Noguchi T, Mechtcherine V (2020) Effects of strain rate on the tensile behavior of cementitious composites made with amorphous metallic fiber. Cement Concr Compos 108:103519

    Article  Google Scholar 

  47. Dupont D, Vandewalle L (2005) Distribution of steel fibres in rectangular sections. Cement Concr Compos 27(3):391–398

    Article  Google Scholar 

  48. Colombo I, Colombo M, Magri A, Zani G, di Prisco M (2011) Textile reinforced mortar at high temperatures. Appl Mech Mater 82:202–207

    Article  Google Scholar 

  49. ASTM C109 (2008) Standard test method for compressive strength of hydraulic cement mortars. West Conshohocken, PA

  50. Hofbeck JA, Ibrahim IO, Mattock AH (1969) Shear transfer in reinforced concrete. J Proc 66(2):119–128

    Google Scholar 

  51. JSCE-G 553 (1999) Test method for shear strength of steel fiber reinforced concrete. Standard specifications for concrete structures, test methods and specifications, Japan Society of Civil Engineers (JSCE), Tokyo

  52. Bažant ZP, Pfeiffer PA (1986) Shear fracture tests of concrete. Mater Struct 19(2):111

    Article  Google Scholar 

  53. Soetens T, Matthys S (2017) Shear-stress transfer across a crack in steel fibre-reinforced concrete. Cement Concr Compos 82:1–13

    Article  Google Scholar 

  54. Barhum R, Mechtcherine V (2012) Effect of short, dispersed glass and carbon fibres on the behaviour of textile-reinforced concrete under tensile loading. Eng Fract Mech 92:56–71

    Article  Google Scholar 

  55. Li QH, Sun CJ, Xu SL (2019) Thermal and mechanical properties of ultrahigh toughness cementitious composite with hybrid PVA and steel fibers at elevated temperatures. Compos Part B Eng 176:107201

    Article  Google Scholar 

  56. Li Q, Gao X, Xu S, Peng Y, Fu Y (2016) Microstructure and mechanical properties of high-toughness fiber-reinforced cementitious composites after exposure to elevated temperatures. J Mater Civ Eng 28(11):04016132

    Article  Google Scholar 

  57. Liu JC, Tan KH (2017) Deformed steel fiber hardening cementitious composite with hybrid PVA and steel fibers. Constr Build Mater 135:600–611

    Article  Google Scholar 

  58. Vecchio FJ, Collins MP (1986) The modified compression-field theory for reinforced concrete elements subjected to shear. ACI J 83(2):219–231

    Google Scholar 

  59. ACI Committee 549 (2013) ACI 549.4R-13: guide to design and construction of externally bonded fabric- reinforced cementitious matrix (FRCM) systems for repair and strengthening concrete and masonry structures. American Concrete Institute

  60. ACI Committee 440 (2017) ACI 440.2R-17: guide for the design and construction of externally bonded FRP systems for strengthening concrete structures. American Concrete Institute

  61. Tran MT, Vu XH, Ferrier E (2018) Experimental and analytical analysis of the effect of fibre treatment on the thermomechanical behaviour of continuous carbon textile subjected to simultaneous elevated temperature and uniaxial tensile loadings. Constr Build Mater 183:32–45

    Article  Google Scholar 

  62. Gibson AG, Wu YS, Evans JT, Mouritz AP (2006) Laminate theory analysis of composites under load in fire. J Compos Mater 40(7):639–658

    Article  Google Scholar 

  63. Jongvivatsakul P, Attachaiyawuth A, Pansuk W (2016) A crack-shear slip model of high-strength steel fiber-reinforced concrete based on a push-off test. Constr Build Mater 126:924–935

    Article  Google Scholar 

  64. Moghadam MA, Izadifard R (2019) Evaluation of shear strength of plain and steel fibrous concrete at high temperatures. Constr Build Mater 215:207–216

    Article  Google Scholar 

  65. Kaufmann W, Amin A, Beck A, Lee M (2019) Shear transfer across cracks in steel fibre reinforced concrete. Eng Struct 186:508–524

    Article  Google Scholar 

  66. Pfyl T (2003) Tragverhalten von stahlfaserbeton, vol 279. vdf Hochschulverlag AG

  67. Abdallah S, Fan M, Cashell KA (2017) Pull-out behaviour of straight and hooked-end steel fibres under elevated temperatures. Cem Concr Res 95:132–140

    Article  Google Scholar 

Download references

Funding

This research was funded by the Basic Science Research Program through the National Research Foundation of Korea funded by the Ministry of Education (NRF- 2020R1A6A1A03044977).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kyoung-Kyu Choi.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Below is the link to the electronic supplementary material.

Supplementary file1 (DOCX 4415 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Dinh, N.H., Van Tran, H. & Choi, KK. Direct shear behavior after elevated temperature exposure of epoxy-coated carbon textile-reinforced mortar (TRM) modified with different types of microfibers. Mater Struct 54, 151 (2021). https://doi.org/10.1617/s11527-021-01748-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1617/s11527-021-01748-0

Keywords

Navigation