Skip to main content
Log in

Application of an Electronic Nose Based on Piezoelectric Sensors for Scanning Volatile Compounds of Gynecological Tests

  • ARTICLES
  • Published:
Journal of Analytical Chemistry Aims and scope Submit manuscript

Abstract

We proposed a method for the rapid assessment of the state of adverse processes in gynecological patients, using highly volatile compounds of an invasive biological test (cervical mucus), which makes it possible to assess the patient’s gynecological status in real time in a doctor’s office. A highly sensitive detector based on seven mass-sensitive piezoelectric sensors containing nanostructured electrode modifiers, having different selectivity to volatile biomolecules (alcohols, aldehydes, ketones, acids, amines) was used. Simple quantitative and qualitative parameters of a sensor array for a mixture of volatile compounds released by a bioassay are considered and substantiated. The boundaries of the quantitative parameters of the sensor array for ranking the samples into the groups “conditionally healthy,” “inflammation/infection,” and “remission” are considered. The ranges of normalized quantitative parameters of the array of the studied sensors, corresponding to the boundaries of unambiguous decision-making on the state of the bioassay and processes in the body, were identified. For the “conditionally healthy” group, the reliable estimate is in the range of up to 1%, for the “remission” group, it is 20–40%, and for the “inflammation/infection” group, it is more than 60%. A procedure for assessing the gynecological status of a person by volatile compounds of cervical mucus using an electronic nose was developed. The procedure was tested together with gynecologists in real conditions of appointment and medical examination of patients. The accuracy of ranking the samples into the groups “conditionally healthy,” “inflammation/infection,” and “remission” is 90%; the analysis time is 5–10 min. No internal calibration of the sensors is required; the reliable operation time of the array is at least 1 year; the performance of the procedure is 5 samples/h.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.

Similar content being viewed by others

REFERENCES

  1. Zdravookhranenie v Rossii 2019: Statististicheskii sbornik (Healthcare in Russia 2019: Statistical Review) Moscow: Rosstat, 2019, p. 170. https://rosstat.gov.ru/storage/mediabank/Zdravoohran-2019.pdf. Accessed February 23, 2021.

  2. Ambulatorno-poliklinicheskaya pomoshch’ v akusherstve i ginekologii (Outpatient and Polyclinic Care in Obstetrics and Gynecology), Sidorova, I.S., Ovsyannikova, T.V., and Makarov, I.O., Eds., Moscow: MEDPress-Inform, 2009.

  3. Ginekologiya: natsional’noe rukovodstvo (Gynecology: National Guidelines), Savel’eva, G.M., Sukhikh, G.T., Serov, V.N., Radzinskii, V.E., and Manukhin, I.B., Eds., Moscow: GEOTAR-Media, 2017, 2nd ed.

    Google Scholar 

  4. Serov, V.N., Dubnitskaya, L.V., and Tyutyunnik, V.L., Ross. Med. Zh. Mat Ditya. Akush. Ginekol., 2011, no. 1, p. 46.

  5. Yurasov, I.V., Extender Abstract of the Doctoral (Med.) Dissertation, Volgograd, 2015.

  6. Hsu, M.I. and Lin, H.W., Int. J. Gynecol. Obstet., 2014, vol. 121, no. 3, p. 337.

    Google Scholar 

  7. Lin, H.W., Tu, Y.Y., and Lin, S.Y., Lancet Oncol., 2011, vol. 12, no. 9, p. 900.

    Article  Google Scholar 

  8. Vinogradova, O.P., Gladilin, G.P., and Kuznetsova, M.N., Doktor.Ru, 2013, no. 1, p. 9.

  9. Kuchmenko, T.A., Shuba, A.A., Tyurkin, I.A., and Bityukova, V.V., J. Anal. Chem., 2014, vol. 69, no. 5, p. 485.

    Article  CAS  Google Scholar 

  10. Sensorika–New Technologies. http://sensorika.testvzh.ru/category/uslugi. Accessed February 23, 2021.

  11. Kuchmenko, T.A., RF Patent 2279065, 2006.

  12. Kuchmenko, T.A., Shuba, A.A., and Bel’skikh, N.V., Analitika Kontrol’, 2012, vol. 16, no. 2, p. 151.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to T. A. Kuchmenko.

Ethics declarations

Conflict of interest. The authors declare that they have no conflicts of interest.

Statement of compliance with standards of research involving humans as subjects. All procedures performed in studies involving human participants were in accordance with the rules and ethics of research, confirmed by the Protocol of the Ethical committee no. 7 of November 30, 2017, Burdenko State Medical University, Voronezh, Russia. Informed consent was obtained from all individual participants involved in the study.

Additional information

Translated by O. Zhukova

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kuchmenko, T.A., Dorovskaya, E.S., Bosikova, Y.N. et al. Application of an Electronic Nose Based on Piezoelectric Sensors for Scanning Volatile Compounds of Gynecological Tests. J Anal Chem 76, 868–880 (2021). https://doi.org/10.1134/S1061934821070066

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1061934821070066

Keywords:

Navigation