Horm Metab Res 2021; 53(07): 444-452
DOI: 10.1055/a-1475-4600
Endocrine Care

Value of [11C]-Methionine PET/CT in Preoperative Localization of Parathyroid Adenomas

1   Department of Endocrinology, University Hospital Brussels, Jette, Belgium
,
Brigitte Velkeniers
1   Department of Endocrinology, University Hospital Brussels, Jette, Belgium
,
Marleen Keyaerts
2   Department of Nuclear Medicine, University Hospital Brussels, Jette, Belgium
,
Steven Raeymaeckers
3   Department of Radiology, University Hospital Brussels, Jette, Belgium
,
Marian Vanhoeij
4   Department of Surgery, University Hospital Brussels, Jette, Belgium
,
Susanne Blotwijk
5   Interfaculty Center Data Processing and Statistics, Vrije Universiteit Brussel , Jette, Belgium
,
Bert Bravenboer
1   Department of Endocrinology, University Hospital Brussels, Jette, Belgium
› Author Affiliations

Abstract

There are multiple imaging modalities in primary hyperparathyroidism. Ultrasound examination and subtraction scintigraphy are usually the first-line imaging techniques. When these results are negative or inconsistent, additional [11C]-methionine PET/CT (MET-PET/CT) or 4-dimensional computed tomography can be performed. ​This study aims to evaluate MET-PET/CT in comparison with other imaging techniques in primary hyperparathyroidism. This is a retrospective cohort study. Eighty-four patients with primary hyperparathyroidism, who underwent parathyroid surgery, were included. ​Imaging results have been correlated to the perioperative drop in parathyroid hormone level and to the pathological analysis. ​Descriptive statistics are used, supplemented with 95% Clopper–Pearson confidence intervals for sensitivity and specificity and a sub-analysis with the McNemar test on paired data only. The per-lesion sensitivity of MET-PET/CT seems higher than that of [99mTc]-sestamibi or [99mTc]-tetrofosmin and [99mTc]-pertechnetate subtraction scintigraphy. The McNemar test, on paired data only, shows significantly higher sensitivity of MET-PET/CT compared to ultrasound (p=0.039) and significantly higher specificity of ultrasound compared to subtraction scintigraphy (p=0.035).​ MET-PET/CT after inconclusive or negative ultrasound and/or subtraction scintigraphy has an additional value in 70% of the cases.​ Preoperative parathyroid hormone levels were higher in patients in whom MET-PET/CT correctly predicted the pathological parathyroid glands, compared to those where MET-PET/CT missed at least one adenoma. The same trend was seen for 4-dimensional computed tomography. In conclusion, MET-PET/CT seems a valuable imaging modality in primary hyperparathyroidism, at least as second line imaging approach, with a higher per-lesion sensitivity than ultrasound in such setting. Especially when ultrasound and/or subtraction scintigraphy are inconclusive or negative, MET-PET/CT directs the surgeon to the correct localization of the parathyroid adenoma.



Publication History

Received: 13 March 2021

Accepted after revision: 22 March 2021

Article published online:
24 June 2021

© 2021. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Garmendia Madariaga A, Santos Palacios S, Guillén-Grima F. et al. The incidence and prevalence of thyroid dysfunction in Europe: A meta-analysis. J Clin Endocrinol Metab 2014; 99: 923-931
  • 2 Fraser WD. Hyperparathyroidism. Lancet 2009; 374: 145-158
  • 3 Bilezikian JP, Bandeira L, Khan A. et al. Hyperparathyroidism. Lancet 2018; 391: 168-178
  • 4 Bhadada SK, Arya AK, Mukhopadhyay S. et al. Primary hyperparathyroidism: insights from the Indian PHPT registry. J Bone Miner Metab 2018; 36: 238-245
  • 5 Hindie E, Zanotti-Fregonara P, Tabarin A. et al. The role of radionuclide imaging in the surgical management of primary hyperparathyroidism. J Nucl Med 2015; 56: 737-744
  • 6 Udelsman R, Akerstrom G, Biagini C. et al. The surgical management of asymptomatic primary hyperparathyroidism: Proceedings of the Fourth International Workshop. J Clin Endocrinol Metab 2014; 99: 3595-3606
  • 7 Bilezikian JP. Primary hyperparathyroidism. Endocr Pract 2012; 18: 781-790
  • 8 Agha A, Hornung M, Stroszczynski C. et al. Highly efficient localization of pathological glands in primary hyperparathyroidism using contrast-enhanced ultrasonography (CEUS) in comparison with conventional ultrasonography. J Clin Endocrinol Metab 2013; 98: 2019-2025
  • 9 Bergenfelz AO, Jansson SK, Wallin GK. et al. Impact of modern techniques on short-term outcome after surgery for primary hyperparathyroidism: A multicenter study comprising 2,708 patients. Langenbecks Arch Surg 2009; 394: 851-860
  • 10 Ishibashi M, Nishida H, Hiromatsu Y. et al. Comparison of technetium-99m-MIBI, technetium-99m-tetrofosmin, ultrasound and MRI for localization of abnormal parathyroid glands. J Nucl Med 1998; 39: 320-324
  • 11 Kedarisetty S, Fundakowski C, Ramakrishnan K. et al. Clinical Value of Tc99m-MIBI SPECT/CT Versus 4D-CT or US in Management of Patients With Hyperparathyroidism. Ear Nose Throat J 2019; 98: 149-157
  • 12 Raeymaeckers S, De Brucker Y, Vanderhasselt T. et al. Detection of parathyroid adenomas with wide-beam multiphase CT. Towards a true 4-dimensional visualization technique with quantitative analysis of perfusion parameters. Conference; November. 2018; Chicago
  • 13 Day KM, Elsayed M, Beland MD. et al. The utility of 4-dimensional computed tomography for preoperative localization of primary hyperparathyroidism in patients not localized by sestamibi or ultrasonography. Surgery 2015; 157: 534-539
  • 14 Madorin CA, Owen R, Coakley B. et al. Comparison of radiation exposure and cost between dynamic computed tomography and sestamibi scintigraphy for preoperative localization of parathyroid lesions. JAMA Surg 2013; 148: 500-503
  • 15 Cheung K, Wang TS, Farrokhyar F. et al. A meta-analysis of preoperative localization techniques for patients with primary hyperparathyroidism. Ann Surg Oncol 2012; 19: 577-583
  • 16 Hellman P, Ahlstrom H, Bergstrom M. et al. Positron emission tomography with 11C-methionine in hyperparathyroidism. Surgery 1994; 116: 974-981
  • 17 Sundin A, Johansson C, Hellman P. et al. PET and parathyroid L-[carbon-11]methionine accumulation in hyperparathyroidism. J Nucl Med 1996; 37: 1766-1770
  • 18 Yuan L, Liu J, Kan Y. et al. The diagnostic value of 11C-methionine PET in hyperparathyroidism with negative 99mTc-MIBI SPECT: A meta-analysis. Acta Radiol 2017; 58: 558-564
  • 19 Rubello D, Fanti S, Nanni C. et al. 11C-methionine PET/CT in 99mTc-sestamibi-negative hyperparathyroidism in patients with renal failure on chronic haemodialysis. Eur J Nucl Med Mol Imaging 2006; 33: 453-459
  • 20 Tang BN, Moreno-Reyes R, Blocklet D. et al. Accurate pre-operative localization of pathological parathyroid glands using 11C-methionine PET/CT. Contrast Media Mol Imaging 2008; 3: 157-163
  • 21 Lenschow C, Gassmann P, Wenning C. et al. Preoperative (1)(1)C-methionine PET/CT enables focused parathyroidectomy in MIBI-SPECT negative parathyroid adenoma. World J Surg 2015; 39: 1750-1757
  • 22 Noltes ME, Coester AM, van der Horst-Schrivers ANA. et al. Localization of parathyroid adenomas using (11)C-methionine pet after prior inconclusive imaging. Langenbecks Arch Surg 2017; 402: 1109-1117
  • 23 Chun IK, Cheon GJ, Paeng JC. et al. Detection and Characterization of Parathyroid Adenoma/Hyperplasia for Preoperative Localization: Comparison Between (11)C-Methionine PET/CT and (99m)Tc-Sestamibi Scintigraphy. Nucl Med Mol Imaging 2013; 47: 166-172
  • 24 Weber T, Gottstein M, Schwenzer S. et al. Is C-11 Methionine PET/CT Able to Localise Sestamibi-Negative Parathyroid Adenomas?. World J Surg 2017; 41: 980-985
  • 25 Braeuning U, Pfannenberg C, Gallwitz B. et al. 11C-methionine PET/CT after inconclusive 99mTc-MIBI-SPECT/CT for localisation of parathyroid adenomas in primary hyperparathyroidism. Nuklearmedizin 2015; 54: 26-30
  • 26 Caldarella C, Treglia G, Isgro MA. et al. Diagnostic performance of positron emission tomography using (1)(1)C-methionine in patients with suspected parathyroid adenoma: a meta-analysis. Endocrine 2013; 43: 78-83
  • 27 Kluijfhout WP, Pasternak JD, Drake FT. et al. Use of PET tracers for parathyroid localization: A systematic review and meta-analysis. Langenbecks Arch Surg 2016; 401: 925-935
  • 28 Weber T, Cammerer G, Schick C. et al. C-11 methionine positron emission tomography/computed tomography localizes parathyroid adenomas in primary hyperparathyroidism. Horm Metab Res 2010; 42: 209-214
  • 29 Michaud L, Burgess A, Huchet V. et al. Is 18F-fluorocholine-positron emission tomography/computerized tomography a new imaging tool for detecting hyperfunctioning parathyroid glands in primary or secondary hyperparathyroidism?. J Clin Endocrinol Metab 2014; 99: 4531-4536
  • 30 Leung K. [(18)F]Fluorocholine. Molecular Imaging and Contrast Agent Database (MICAD). Bethesda (MD): National Center for Biotechnology Information (US); 2004-2013 Available from: https://www.ncbi.nlm.nih.gov/books/NBK5330/
  • 31 Lezaic L, Rep S, Sever MJ. et al. (1)(8)F-Fluorocholine PET/CT for localization of hyperfunctioning parathyroid tissue in primary hyperparathyroidism: a pilot study. Eur J Nucl Med Mol Imaging 2014; 41: 2083-2089
  • 32 Michaud L, Balogova S, Burgess A. et al. A Pilot Comparison of 18F-fluorocholine PET/CT, Ultrasonography and 123I/99mTc-sestaMIBI Dual-Phase Dual-Isotope Scintigraphy in the Preoperative Localization of Hyperfunctioning Parathyroid Glands in Primary or Secondary Hyperparathyroidism: Influence of Thyroid Anomalies. Medicine (Baltimore) 2015; 94: e1701
  • 33 Kluijfhout WP, Pasternak JD, Gosnell JE. et al. (18)F Fluorocholine PET/MR Imaging in Patients with Primary Hyperparathyroidism and Inconclusive Conventional Imaging: A Prospective Pilot Study. Radiology 2017; 284: 460-467
  • 34 Beheshti M, Hehenwarter L, Paymani Z. et al. (18)F-Fluorocholine PET/CT in the assessment of primary hyperparathyroidism compared with (99m)Tc-MIBI or (99m)Tc-tetrofosmin SPECT/CT: A prospective dual-centre study in 100 patients. Eur J Nucl Med Mol Imaging 2018; 45: 1762-1771
  • 35 Broos WAM, van der Zant FM, Knol RJJ. et al. Choline PET/CT in parathyroid imaging: A systematic review. Nucl Med Commun 2019; 40: 96-105
  • 36 Treglia G, Piccardo A, Imperiale A. et al. Diagnostic performance of choline PET for detection of hyperfunctioning parathyroid glands in hyperparathyroidism: A systematic review and meta-analysis. Eur J Nucl Med Mol Imaging 2019; 46: 751-765
  • 37 Wilhelm SM, Wang TS, Ruan DT. et al. The American Association of Endocrine Surgeons Guidelines for Definitive Management of Primary Hyperparathyroidism. JAMA Surg 2016; 151: 959-968
  • 38 Payne RB, Little AJ, Williams RB. et al. Interpretation of serum calcium in patients with abnormal serum proteins. Br Med J 1973; 4: 643-646
  • 39 Jassam N, Gopaul S, McShane P. et al. Calcium adjustment equations in neonates and children. Ann Clin Biochem 2012; 49: 352-358
  • 40 Castellano E, Attanasio R, Boriano A. et al. Sex Difference in the Clinical Presentation of Primary Hyperparathyroidism: Influence of Menopausal Status. J Clin Endocrinol Metab 2017; 102: 4148-4152
  • 41 Deloar HM, Fujiwara T, Nakamura T. et al. Estimation of internal absorbed dose of L-[methyl-11C]methionine using whole-body positron emission tomography. Eur J Nucl Med 1998; 25: 629-633
  • 42 Christner JA, Kofler JM, McCollough CH. Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning. AJR Am J Roentgenol 2010; 194: 881-889
  • 43 Hayakawa N, Nakamoto Y, Kurihara K. et al. A comparison between 11C-methionine PET/CT and MIBI SPECT/CT for localization of parathyroid adenomas/hyperplasia. Nucl Med Commun 2015; 36: 53-59