Assessment of the inverse dispersion method for the determination of methane emissions from a dairy housing

https://doi.org/10.1016/j.agrformet.2021.108501Get rights and content
Under a Creative Commons license
open access

Highlights

  • Methane (CH4) emission measurements were conducted at a housing with 40 dairy cows.

  • Inverse dispersion method (IDM) was compared with an “inhouse” tracer ratio method.

  • Differences between means of 1-8% are within the uncertainty range of either method.

  • IDM CH4 emissions were 317±44 and 267±43 g LU−1 day−1 for two campaigns.

  • An uncertainty analysis suggests a measurement duration of at least 10 days for IDM.

Abstract

Methane (CH4) emissions from dairy housings, mainly originating from enteric fermentation of ruminating animals, are a significant source of greenhouse gases. The quantification of emissions from naturally ventilated dairy housings is challenging due to the spatial distribution of sources (animals, housing areas) and variable air exchange. The inverse dispersion method (IDM) is a promising option, which is increasingly used to determine gaseous emissions from stationary sources, as it offers high flexibility in the application at reasonable costs. We used a backward Lagrangian stochastic model combined with concentration measurements by open-path tunable diode laser spectrometers placed up- and downwind of a naturally ventilated housing with 40 dairy cows to determine the CH4 emissions. The average emissions per livestock unit (LU) were 317 (±44) g LU−1 d−1 and 267 (±43) g LU−1 d−1 for the first and second campaign, in September – October and November – December, respectively. For each campaign, inhouse tracer ratio measurements (iTRM) were conducted in parallel during two subperiods. For simultaneous measurements, IDM showed average emissions which were lower by 8% and 1% than that of iTRM, respectively, for the two campaigns. The differences are within the uncertainty range of any of the two methods. The IDM CH4 emissions were further analysed by wind direction and atmospheric stability and no differences in emissions were found. Overall, IDM showed its aptitude to accurately determine CH4 emissions from dairy housings or other stationary sources if the site allows adequate placement of sensors up- and downwind in the prevailing wind direction. To acquire reliable emission data, depending on the data loss during measurements due to quality filtering or instrument failure, a measuring time of at least 10 days is required.

Keywords

GasFinder3
Open-path tunable diode laser
Backward Lagrangian stochastic
Inhouse tracer ratio method
Uncertainty analysis
Enteric fermentation

Cited by (0)