Abstract
The bare optical fiber of 0.12 mm o.d. has been introduced as the support material in gas chromatography. Two fused-silica fibers coated with polydimethylsiloxane (SE30) were longitudinally packed into a 2 m SE30 capillary column (SE30-CFs-packed SE30-CC), followed by studying chromatographic performances. With 0.012 g/mL SE30 solution coating onto the packed fibers, the efficiency per unit length of SE30-CFs-packed SE30-CC was 1695 plates/m (for the separation of n-hexadecane at 120°С). The retention power and sample loading capacity of this SE30-CFs-packed SE30-CC were improved over a single SE30-coated fused-silica fiber in a SE30-coated capillary annular column (SE30-CF/SE30-CC) as well as a conventional SE30 capillary column (HP-1). The results showed the contribution of the two coated fused-silica fibers to the retentivity and sample loading capacity of the column. With a large injection, SE30-CFs-packed SE30-CC provided better separation for hidden harmful solvents in beta-cypermethrin malathion than SE30-CF/SE30-CC and HP-1 of the same length.
Similar content being viewed by others
REFERENCES
Gross, G.M., Nelson, D.A., Grate, J.W., and Synovec, R.E., Anal. Chem., 2003, vol. 75, no. 17, p. 4558.
Speltini, A., Merli, D., and Profumo, A., Anal. Chim. Acta, 2013, vol. 783, p. 1.
Poole, C.F. and Poole, S.K., J. Chromatogr. A, 2008, vol. 1184, nos. 1–2, p. 254.
Chang. N. and Yan, X.P., J. Chromotogr. A, 2012, vol. 1257, p. 116.
Shen, G., Cui, J., Yang, X., and Ling, Y., J. Sep. Sci., 2008, vol. 32, no. 1, p. 79.
Zhang, X., Ji, H., Zhang, X., Wang, Z., and Xiao, D., Anal. Methods, 2015, vol. 7, p. 3229.
Saito, Y., Imaizumi, M., Nakata, K., Takeichi, T., Kotera, K., Wada, H., and Jinno, K., J. Micro. Sep., 2001, vol. 13, no. 7, p. 259.
Saito, Y., Tahara, A., Imaizumi, M., Takeichi, T., Wada, H., and Jinno, K., Anal. Chem., 2003, vol. 75, no. 20, p. 5525.
Saito, Y., Tahara, A., Ogawa, M., Imaizumi, M., Ban, K., Wada, H., and Jinno, K., Anal. Sci., 2004, vol. 20, no. 2, p. 335.
Abe, A., Saito, Y., Imaizumi, M., Ogawa, M., Takeichi, T., and Jinno, K., J. Sep. Sci., 2005, vol. 28, no. 17, p. 2413.
Saito,Y., Ogawa, M., Imaizumi, M., Ban, K., Abe, A., Takeichi, T., Wada, H., and Jinno, K., J. Chromatogr. Sci., 2005, vol. 43, no. 10, p. 536.
Saito, Y., Ogawa, M., Imaizumi, M., Ban, K., Abe, A., Takeichi, T., Wada, H., and Jinno, K., Anal. Bioanal. Chem., 2005, vol. 382, no. 3, p. 825.
Ogawa, M., Saito, Y., Imaizumi, M., Wada, H., and Jinno, K., Chromatographia, 2006, vol. 63, nos. 9–10, p. 459.
Dietz, C., Sanz, J., and Cámara, C., J. Chromatogr. A, 2006, vol. 1103, no. 2, p. 183.
Liu, H., Li, J., Liu, X., and Jiang, S., Talanta, 2009, vol. 78, no. 3, p. 929.
Amini, R., Rouhollahi, A., Adibi, M., and Mehdinia, A., J. Chromatogr. A, 2011, vol. 1218, no. 1, p. 130.
Davarani, S.S.H., Masoomi, L., Banitaba, M.H.O., and Samiei, A., Talanta, 2013, vol. 105, p. 347.
Li, P., Xu, Z., Yang, X., Bi, W., Xiao, D., and Choi, M.M.F., J. Chromatogr. A, 2009, vol. 1216, no. 15, p. 3343.
Qiu, W., Diao, P., Yuan, H., Xiao, D., and Choi, M.M.F., Anal. Lett., 2011, vol. 44, no. 16, p. 2721.
Liu, H., Gas Chromatography and Its Application, Beijing: Chemical Industry, 2014.
Brandys. J., Forensic Sci. Int., 1988, vol. 38, nos. 3–4, p. 185.
Gross, G.M., Grate, J.W., and Synovec, R.E., J. Chromatogr. A, 2004, vol. 1060, nos. 1–2, p. 225.
Funding
Financial support from National Natural Science foundation of China (20775050), and Sichuan Vocational College of Health and Rehabilitation crossing research project (CWKY-2020H-01) are gratefully acknowledged.
Author information
Authors and Affiliations
Corresponding authors
Ethics declarations
The authors declare that they have no conflicts of interest.
Rights and permissions
About this article
Cite this article
Qiu, W., Ling, L., Zhou, L. et al. Two Fibers Packed in Capillary Column for Gas Chromatographic Separation. J Anal Chem 76, 755–760 (2021). https://doi.org/10.1134/S1061934821060113
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1061934821060113