Investigation of corrosion and thermal behavior of PU–PDMS-coated AISI 316L

  • Muharrem Taşdemir EMAIL logo , Fatih Şenaslan and Ayhan Çelik
From the journal e-Polymers

Abstract

Polydimethylsiloxane (PDMS) is widely used from biomedical to industrial applications due to its nontoxic, hydrophobic, and transparent characteristics. PDMS has good thermal and adhesion properties; however, its mechanical properties are comparatively weak. Therefore, PDMS is blended with various polymers to effectively improve its mechanical properties. In this study, polyurethane (PU)–polydimethylsiloxane (PDMS) blended coatings of different concentrations were applied on the AISI 316L stainless steel surface. Their effects on corrosion and tribocorrosion properties were investigated in Ringer’s solutions. The blended polymer coatings were characterized using Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS). The thermal properties of samples were examined by TGA and DSC. The surface images and cross-sectional were investigated using scanning electron microscopy (SEM). Tribocorrosion tests were carried out at open circuit potential (OCP). It was determined that hydrophobicity and thermal stability of polymer coating increased, while corrosion resistance slightly decreased with the increasing PDMS concentration in the polymer blended. The friction coefficient of blends decreased as the PU concentration increased. As a result, it was determined that the polymer-coated samples containing up to 50% PDMS prevented corrosive wear under the OCP wear test in Ringer’s solutions.

1 Introduction

Polydimethylsiloxane (PDMS) is widely used from biomedical to industrial applications due to its advantages of being a transition polymer in between organic and inorganic polymers (1). PDMS is a non-toxic, highly hydrophobic, and transparent polymer (2). PDMS is used in biomedical industries due to its good blood compatibility, low toxicity, good thermal and oxidative stability, low modulus, and antiadhesive properties. PDMS exhibits mechanical properties similar to human tissue (elastic modulus of 2 MPa) (3). PDMS is used as a biomaterial in controlled drug release systems, cardiac medicine, drainage implants, artificial skin, contact lenses, oxygenators, medical adhesives, blood pumps, and catheters (4,5). PDMS-coated materials are used in industrial applications because of their as anticorrosive, anti-icing, self-cleaning, antireflective properties (6,7). The silicon–oxygen and silicon–hydroxide bonds of PDMS provide thermal stability, with strong adhesion to glass or metal surfaces (8).

PDMS has good thermal, adhesive, and corrosion-resistant properties, but it cannot precisely carry out its function due to its inadequate mechanical properties (9,10). To improve the mechanic and wear properties of PDMS, various treatments such as blending, adding nanoparticles, bulk, and surface modification are applied (11,12,13,14,15). Among these, the blending method is the relatively simple, practical, and low-cost technique (16). PDMS is blended with various polymers to improve its poor mechanical properties. Polymer blending is the combination of at least two polymers to form a new material with different properties (17). Polymer blends exhibit various properties depending on the component’ amounts. These properties are a result of the mechanical, thermal, and chemical properties of each component (18,19). Polyurethane (PU) is the most preferred material to improve the mechanical and corrosion-resistant properties of PDMS (20,21). PU–PDMS blending is elastic, biocompatible, chemically inertness, and enhanced thermal and oxidative properties and can be used in surgical applications (22,23,24).

Studies investigating PU and PDMS blends as biomaterials can be found in the published literature (25). However, there is no study in the published literature investigating the corrosion and tribocorrosion of polymer-blended coatings consisting of PU and PDMS on AISI 316L stainless steel. Hence, this study fills an important deficiency of polymer-based biomaterials working under tribocorrosion conditions. The working material exposed to various aqueous solutions or compounds is damaged over time. This situation based on solution–material interaction is expressed by tribocorrosion (26). Tribocorrosion is vital, especially in biomedical applications where both corrosion and mechanical wear occur. In this study, the effects of corrosion, tribocorrosion, and the thermal properties of different proportions of PU–PDMS blends on AISI 316L stainless steel were investigated.

2 Materials and method

In this study, AISI 316L stainless steel was used as the substrate material. PU Pellethane 2363-90A was obtained from Lubrizol. PDMS Sylgard 184 was supplied from Dow Corning in two components. Sylgard 184 PDMS has high crystallinity and viscosity, as well as nontoxic and inert properties. The molecular weight and density of PDMS are 27,000 and 0.982 g/mL, respectively. PU and PDMS were dissolved in a solution containing 20% (w/w) polymer in tetrahydrofuran (THF) + dimethylacematide (DMAc). This solution was stirred for 1 day at 22°C. AISI 316L stainless steel samples were coated by dipping them into this solution. PU–PDMS blends of different ratios such as 75:25, 50:50, and 25:75 PU–PDMS were prepared to coat onto AISI 316L stainless steel. The prepared samples were left to dry at room temperature. The process was applied under vacuum conditions to avoid air bubbles in coatings. Figure 1 shows the schematic representation of the dip-coating process. FTIR measurements were carried out in the wavelength ranging from 400 to 4,000 cm−1 MIR at a resolution of 2 cm−1. The XRD patterns of polymer-coated samples were characterized by XRD diffraction (Panalytical Empyrean) with Cu-Kα. XPS measurements were conducted by Specs-Flex XPS equipment. The surface images and cross-sectional samples were analyzed with SEM equipment Zeiss Sigma 300. The potentiodynamic and electrochemical impedance spectroscopy (EIS) measurements of untreated and polymer-coated samples were investigated using a Gamry G750 potentiostat in Ringer’s solution. The chemical composition of Ringer’s solution is presented in Table 1.

Figure 1 
               The schematic representation of the dip-coating process. (a) Dipping, (b) formation of polymer layer, and (c) evaporation.
Figure 1

The schematic representation of the dip-coating process. (a) Dipping, (b) formation of polymer layer, and (c) evaporation.

Table 1

Chemical composition of the Ringer’s solution

Content Sodium chloride Potassium chloride Calcium chloride hydrate Sodium hydrogen carbonate
Ingredient (g/L) 6 0.4 0.3 3

A standard three-electrode cell was used for corrosion and tribocorrosion measurements, for which graphite was used as the counter electrode, Ag/AgCl was used as the reference electrode, and the sample was used as the working electrode. The potentiodynamic polarization curves were made at −1 to 2 V at a scanning rate of 1 mV/s over a surface area of 0.3848 cm2. Tribocorrosion tests were performed in an electrochemical cell attached to the wear equipment. Tribocorrosion experiments were performed at a load of 3 N normal to the sample at a frequency of 1 Hz for 3,000 s under open circuit potential (OCP) conditions. Tribocorrosion tests were done with an 8 mm stroke length in an exposed area of 0.4 cm2 in Ringer’s solution. The friction coefficient of samples was also recorded instantaneously in the tribocorrosion experiments. The static contact and the sliding angle of the polymer film were measured with an Attension Theta Flex contact angle device at the room temperature to evaluate hydrophobicity. The sample stage was rotated from 0° to 10° in the sliding angle test. Thermogravimetric (TGA) analysis was carried out using a Hitachi STA 7300 at a heating rate of 10°C/min from 25°C to 700°C under a nitrogen atmosphere. Differential scanning calorimetry (DSC) measurements were performed with DSCQ 2000 equipment at −90°C to 250°C with a heating and cooling rate of 10°C/min under a nitrogen atmosphere.

3 Results and discussion

3.1 Characterization of polymer coatings

An FTIR graph for PU–PDMS coatings is shown in Figure 2. The adsorption peak at 3,321 cm−1 represents the N–H urethane peak of PU. The intensity of the urethane peak decreased with the increasing PDMS content. The peaks between 2,950 and 2,970 cm−1 correspond to the asymmetric Si–CH3 bonds of PDMS. The peaks at 1,257 and 1,010 cm−1 are attributed to CH3 asymmetric deformation and Si–O–Si asymmetric deformation of PDMS. The spectrum of PU–PDMS blends shows 798 cm−1 CH3 release and Si–C cm−1 vibrations (20). Polysiloxanes represent a big group of polymers with inorganic main chains. The surface properties of PDMS are a result of weak intermolecular forces between methyl groups as well as the strong Si–O bond and flexible Si–O–Si bond. PDMS shows nonpolar properties due to methyl groups outside the siloxane chain (21). Thus, PDMS shows excellent adhesion to metal surfaces due to these properties.

Figure 2 
                  FTIR graph of PU–PDMS coatings  (a) from 3500 to 2600, and (b) from 1800–400.
Figure 2

FTIR graph of PU–PDMS coatings (a) from 3500 to 2600, and (b) from 1800–400.

The XRD results of PU–PDMS polymer coatings are presented in Figure 3. It was observed that XRD peaks of PU and PDMS formed a wide range since polymeric structures were amorphous: 2θ = 12.5° PDMS peak and 2θ = 20.5° urethane peak of PU. XRD intensity peaks of PU–PDMS changed depending on the blending proportions. For the PU75–PDMS25 blend, the intensity urethane peak decreased and the PDMS peak began to appear. The PU50–PDMS50 blend formed equal urethane and PDMS peaks. As expected, the PU25–PDMS75 blend increased the intensity of the PDMS peak while decreasing the urethane peak significantly. The results indicated that as the PU content increased, the PDMS peak decreased. The XRD peaks of PDMS and PU were 2θ = 12.1° and 2θ = 20°, respectively, in the previous studies (27,28).

Figure 3 
                  The XRD results of PU–PDMS polymer coatings.
Figure 3

The XRD results of PU–PDMS polymer coatings.

The crystallinity of PU, PU75–PDMS25, PU50–PDMS50, PU25–PDMS75, and PDMS are 62.8%, 64.9%, 69.7%, 71.1%, and 72.4%, respectively. It was revealed that the crystallization of the polymer increased with the increasing PDMS concentration in the coating due to the high crystallinity of PDMS. The XPS wide scan spectrum of PU–PDMS polymer blends is shown in Figure 4. Three main elements were detectable for neat PU and PDMS. The XPS spectra of PU are observed at 284, 399, and 532 eV, which are attributed to C 1s, N 1s, and O 1s, respectively. The peak positions of PDMS are O 1s at 532 eV, C 1s at 284 eV, Si 2s at 155 eV, and Si 2p at 102 eV. The presence of peak nitrogen and silicon indicates that PU and PDMS are effectively blended. As shown in Figure 4, a significant increase in silicon concentration and a decrease in carbon and nitrogen concentration occurred due to the increasing PDMS content in the blend (29,30,31).

Figure 4 
                  XPS spectrum of PU–PDMS polymer blends.
Figure 4

XPS spectrum of PU–PDMS polymer blends.

3.2 Surface images

The cross-sectional views of AISI 316L coated with PU–PDMS polymers are shown in Figure 5. The thickness of the PU–PDMS polymer-coated sample layer was 45 µm according to the SEM images of cross-sectional view of samples. The surface view of AISI 316L coated with PU–PDMS polymers is shown in Figure 6. Homogeneous and uniform coatings were produced by the PU–PDMS blends. Figure 6 also shows irregular protrusions of PU, and it indicates that as the PDMS content increased, fracture structures were obtained. The SEM images showed that PU–PDMS blends had a porous structure on the surface, which might be due to the blend interface. It was also clear that there were irregular particles of various sizes on the surface of the blends. In Figure 6, these are particles containing silicon with a size of 1–2 µm. PU–PDMS-coated products attract a great deal of industry attention due to their versatile surface properties.

Figure 5 
                  The cross-sectional views of AISI 316L coated with PU–PDMS polymers: (a) PU75–PDMS25, (b) PU50–PDMS50, and (c) PU25–PDMS75.
Figure 5

The cross-sectional views of AISI 316L coated with PU–PDMS polymers: (a) PU75–PDMS25, (b) PU50–PDMS50, and (c) PU25–PDMS75.

Figure 6 
                  The surface views of AISI 316L coated with PU–PDMS polymers.
Figure 6

The surface views of AISI 316L coated with PU–PDMS polymers.

3.3 Contact angle measurements

The wettability and hydrophobicity of the polymer coatings were investigated using a water contact angle test. The contact angle of the PU–PDMS coatings on AISI 316L is shown in Figure 7. The contact angles of the PU and PDMS are 98° and 112°, respectively. The contact angles of PU75–PDMS25, PU50–PDMS50, and PU25–PDMS75 polymer blends are 101°, 107°, and 109°, respectively. The contact angle increased with the increasing PDMS content in the blend. These results showed that PDMS shows hydrophobic properties and is an effective barrier against water due to siloxane layers.

Figure 7 
                  The contact angle of PU–PDMS polymer coatings on AISI 316L.
Figure 7

The contact angle of PU–PDMS polymer coatings on AISI 316L.

Moreover, methyl groups on the outer surface of the PDMS support a hydrophobic structure and cause low surface energy at the polymer–air interface. The surface properties of PDMS have low surface energy due to the weak intermolecular forces between the methyl groups and the strong (Si–O) and flexible (Si–O–Si) siloxane chain (21). The water adsorption ability of PDMS is negligible due to its hydrophobic nature. Hydrophobic coated materials act as water repellents in aqueous environments. It prevents the adhesion of microorganisms by reducing the surface energy of polymeric coatings (32). However, hydrophobic coatings, especially from a biomedical point of view, cause surface contamination from organic solvents and proteins through the adsorption of small molecules due to its low wetting and heterogeneous surface charge (3). PDMS makes the surface hydrophobic by minimizing the surface energy between the substrate material and the coating. The Si–OH bond of PDMS provides strong bonding to glass or metal surfaces (8). It was determined that water contact angles of PDMS were 108° and 107°, respectively (33,34).

The static contact and the sliding angle of the PU–PDMS-coated AISI 316L steel are presented in Table 2. The sliding contact angles of PU and PDMS are 94° and 110°, respectively. The sliding angles of PU75–PDMS25, PU50–PDMS50, and PU25–PDMS75 polymer blends are 96°, 105°, and 107°, respectively. The sliding angle of polymer-coated samples decreased by 2°–5° compared to the static contact angle.

Table 2

The contact and sliding angles of PU–PDMS coated AISI 316L steel

Sample PU PU75–PDMS25 PU50–PDMS50 PU25–PDMS75 PDMS
Contact angle (°) 98 101 107 109 112
Sliding angle (°) 94 96 105 107 110

3.4 Potentiodynamic and EIS measurements

The potentiodynamic scans and Nyquist plots for AISI 316L coated with PU–PDMS polymers in Ringer’s solution are presented in Figure 8. Figure 8a shows that E corr values for all materials were very close to each other −0.1 V vs V ref. The I corr untreated sample was 2.32 × 10−4 (A/cm2). The I corr values of PDMS, PU25–PDMS75, PU50–PDMS50, PU75–PDMS25, and PU are 5.24 × 10−5, 7.64 × 10−5, 8.79 × 10−5, 4.94 × 10−5, and 1.20 × 10−6 (A/cm2), respectively. All polymer-coated samples showed lower current density compared to the uncoated stainless steel. All polymer-coated samples improved the corrosion resistance properties of the substrate material and displayed a similar passivation behavior in anodic and cathodic regions. Figure 8b shows that the impedance spectra of all samples exhibited the semicircle which the diameter increased with the increasing PU concentration in the blend.

Figure 8 
                  Potentiodynamic scans and Nyquist plots for AISI 316L coated with PU–PDMS polymers in Ringer’s solution: (a) potentiodynamic and (b) Nyquist.
Figure 8

Potentiodynamic scans and Nyquist plots for AISI 316L coated with PU–PDMS polymers in Ringer’s solution: (a) potentiodynamic and (b) Nyquist.

Bode plots for AISI 316 coated with PU–PDMS polymers is shown in Figure 9. Figure 9a shows that although the impedance value of all samples was high at low frequencies, the impedance value of samples decreased as the frequency increased. Polymer-coated samples had higher impedance untreated substrate material. While the phase angle had a high value at low frequencies, it decreased to 103 Hz and then increased again as the frequency increased as shown in Figure 9b. The polymer-coated materials acted as a barrier, which greatly improved the corrosion resistance of the substrate material. The PU-coated sample presented a better performance than the PDMS-coated sample, exhibiting lower corrosion density compared to that of the PDMS-coated sample. This indicated that the PU-coated sample increased the protection of the substrate material because of more oxidative resistance. The PDMS-coated sample exhibited lower corrosion resistance owing to its permeability. The corrosion resistance increased as the concentration of PU increased in the blend. This indicated that PU-coated materials improved corrosion resistance (35).

Figure 9 
                  Bode plots for AISI 316 coated with PU–PDMS polymers in Ringer’s solution: (a) Bode magnitude and (b) Bode phase.
Figure 9

Bode plots for AISI 316 coated with PU–PDMS polymers in Ringer’s solution: (a) Bode magnitude and (b) Bode phase.

3.5 OCP wear

Tribocorrosion is very important in biomedical equipment, where there is mechanical loading and chemical interactions with the surrounding environment (36). OCP wear of AISI 316L coated with PU–PDMS polymers in Ringer’s solution is shown in Figure 10. The OCP wear test was conducted for 3,000 s. The samples were waited to stabilize for 1,000 s before and after the OCP wear test. The potential of all polymer-coated materials is approximately −0.15 V vs V ref before and after the wear loading. When the wear started, the potential values of PU, PU75–PDMS25, and PU50–PDMS50 polymer-coated materials increased positively. This situation stably remained during the test. The results show that PU, PU75–PDMS25, and PU50–PDMS50 polymer coatings protected the surface of the substrate material. This indicated that the wear ball was not in contact with the substrate material. After unloading, the potential values of PU, PU75–PDMS25, and PU50–PDMS50 polymer-coated samples immediately decreased to their initial values. OCP results showed that PU, PU75–PDMS25, and PU50–PDMS50-coated materials can be used in biomaterial applications under wear-corrosion conditions. Potentiodynamic and OCP wear results clearly demonstrated that the PU-coated sample exhibited the best corrosion resistance and tribocorrosion properties.

Figure 10 
                  OCP wear of AISI 316L coated with PU–PDMS polymers in Ringer’s solution.
Figure 10

OCP wear of AISI 316L coated with PU–PDMS polymers in Ringer’s solution.

The PU25–PDMS75 polymer coating exhibited different properties than others for OCP wear test. The PU25-PDMS75 coated sample increased positively first 300 s of the experiment, and then the potential value of this material suddenly dropped to –0.3 V vs V ref. The decreased potential value of this coating gradually continued during wear. It showed that the polymer coating protected the surface for the first 300 s when the wear started. Then, the polymer layer was removed by the effect of the wear load, and the substrate material could not be protected. It gave a hint that mechanical wear has more effect on corrosion. This situation is clearly shown in Figure 11d, where the coating layer is broken due to the wear load. The potential value of the PU25–PDMS75 increases with the effect of repassivation when the wear ends. It is clear that friction coefficients of all polymer-coated samples showed oscillation due to stick-slip. The friction coefficients of PU, PU75–PDMS25, and PU50–PDMS50 polymer-coated samples are 0.2. The friction coefficient of the PU25–PDMS75-coated sample was slightly increased after 300 s when the coating layer was removed. The PU25–PDMS75 polymer-coated material was 0.25. The friction coefficient of polymer-coated samples decreased with an increased concentration of PU in the blend.

Figure 11 
                  OCP wear surface images of AISI 316L coated with PU–PDMS polymers in Ringer’s solution: (a) PU, (b) PU75–PDMS25, (c) PU50–PDMS50, and (d) PU25–PDMS75.
Figure 11

OCP wear surface images of AISI 316L coated with PU–PDMS polymers in Ringer’s solution: (a) PU, (b) PU75–PDMS25, (c) PU50–PDMS50, and (d) PU25–PDMS75.

OCP wear surface images of AISI 316L coated with PU–PDMS polymers in Ringer’s solution are shown in Figure 11. PU exhibited the lowest wear scar and the depth. The wear scar and the depth of the polymers significantly increased with incremental in the PDMS content. This can be attributed to the weakness of the PDMS mechanical properties (37). Furthermore, for all blends, it was observed that the wear volume increased with an increase in the PDMS concentration in the coating. The PU-coated sample showed better wear resistance compared to PU/PDMS blends. The wear mechanism of PU and PU75–PDMS25 polymer-coated material was abrasive. Figure 11d shows that the PU25–PDMS75 layer was broken due to the wear load. This can be attributed to the decrease in wear resistance in polymer wear resistance due to the weak mechanical properties of PDMS.

3.6 TGA, difference thermogravimetry, and DSC analysis

TGA, difference thermogravimetry (DTG), and DSC measurements were performed to determine the thermal properties of the polymers. TGA and DTG measurements of PU–PDMS polymers are shown in Figure 12. The TGA analysis of PU–PDMS polymers is shown in Figure 12a. PU showed almost no change in its weight up to 280°C and preserved its stability. PU weight decreased rapidly when the PU hard segment melted at 280°C, and this situation continued up to 390°C. The decrease in the amount of material up to 400°C in the PDMS is related to the loss of absorbed water (38). The weight of PDMS was sharply reduced in the temperature range from 400°C to 600°C. It shows depolymerization in the siloxane chains. The thermal degradation of PDMS is mainly related to Si–O’s heterolytic separation, where bonds interact significantly in the kinetic state and within the molecular structure (39). The amount of thermal degradation of PDMS determines the intermolecular formation (40). PU–PDMS polymer blends are virtually nondegradable up to 280°C. The amount of the degraded substance increased as the amount of PU increased in the blend after 280°C. This situation is due to the low thermal stability of PU. PU showed two steps of degradation. The first weight loss at 330°C was due to the hard segment degradation, while the second weight loss at 390°C was due to the soft segment, as shown in Figure 12b. The hard segment’s decomposition temperature is nearly the same in all blends, but the degradation temperature of the soft segment increased from 390°C to 420°C with the increasing PDMS content. This increase may be due to PDMS replacing the soft segment in the blend and the increased thermal stability. The thermal stability of PDMS provides silicon–oxygen bond strength (8).

Figure 12 
                  TGA (a) and DTG (b) analysis of PU–PDMS polymers.
Figure 12

TGA (a) and DTG (b) analysis of PU–PDMS polymers.

The thermal stability of PU–PDMS polymer blends is presented in Table 3. The heat resistance index and residual weight were calculated from TGA measurements. The heat-resistant index temperatures of PU and PDMS are 153.97°C and 205.43°C, respectively. The heat resistance of the polymers increased with the increasing PDMS content. This increase is due to the silicon in the structure of PDMS. The residual weight of polymers increased with the increase in the PDMS content. This situation shows that PDMS considerably improved the thermal stability of the blends.

Table 3

Thermal stability of PU–PDMS polymer blends

Sample T d5 (°C) T d30 (°C) T d50 (°C) Heat-resistant index (T s) (°C) Residual weight (%)
PU 289.62 330.63 352.69 153.97
PU75–PDMS25 279.58 347.66 404.51 157.01 12
PU50–PDMS50 288.16 385.25 442.23 169.74 19
PU25–PDMS75 281.68 398.01 472.81 172.12 26
PDMS 304.85 495.52 584.18 205.43 43

DSC measurement of PU–PDMS polymers and the glass transition temperature (T g) and melting temperature (T m) of PU–PDMS polymer are given in Figure 13 and Table 4, respectively. The glass transition temperature (T g) of PU is −30°C. The glass transition temperature of PU50–PDMS50 decreased to −50°C with the effect of PDMS. An increasing concentration of PDMS moved the T g of the polymers to lower values. The melting of the hard segment and the soft segment of PU are at 62.5°C and 150°C, respectively. The cold crystallization of PU occurred at 80°C. The melting of the soft segment of PU50–PDMS50 blending was not observed. These results showed that the PU and PDMS were chemically bonded. The melting of PDMS and PU50–PDMS50 occurs at 0°C and 150°C, respectively.

Figure 13 
                  DSC measurement of PU–PDMS polymers.
Figure 13

DSC measurement of PU–PDMS polymers.

Table 4

The glass transition temperature (T g) and melting temperature (T m) of PU–PDMS polymer from DSC analysis

Sample T g (°C) T m (°C)
PU −30 175
PU50/PDMS50 −50 165
PDMS 0

The properties of PU/PDMS polymer blends are presented in Table 5. The contact angle and the thermal stability of polymers increased with an increased concentration of PDMS in the blend. All the polymer coatings on stainless steel protected the substrate material very well in the corrosive environment. The PU coating showed the corrosion and tribocorrosion resistance. The polymer coatings containing up to 50% PDMS protected the substrate surface under tribocorrosion conditions.

Table 5

Properties of PU/PDMS polymer blends

Material Contact angle Residue (%) at 700°C from TGA Corrosion Tribocorrosion OCP wear
PU 98 ++ +
PU75/PDMS25 101 12 + +
PU50/PDMS50 107 19 + +
PU25/PDMS75 109 26 +
PDMS 112 43 +

4 Conclusion

The corrosion, tribocorrosion, and thermal properties of PU–PDMS blends on AISI 316L stainless steel were investigated in Ringer’s solution. The following results were obtained. The hydrophobicity and the thermal stability of coatings increased, whereas corrosion resistance of coating slightly decreased with the increased PDMS concentration in the blend. The wear volume and the friction coefficient of PU–PDMS coatings decreased with the increased PU concentration in the blend. EIS and potentiodynamic results showed that the PU-coated sample had better corrosion resistance than PU–PDMS blended coatings. PU, PU75–PDMS25, and PU50–PDMS50 polymer-coated samples protected the AISI 316L surface under the OCP wear test. However, PU25–PDMS75 coating could not protect the surface due to its weaker mechanical properties. As a result, it was determined that the polymer-coated samples containing up to 50% PDMS prevented corrosive wear under the OCP wear test in Ringer’s solutions.

Acknowledgments

The authors gratefully thank the Coordinatorship of Scientific Research Projects of Ataturk University for providing financial support (Project Code: FDK-2019-7078).

  1. Funding information: This study was financially supported by Ataturk University, Coordinatorship of Scientific Research Projects (Project Code: FDK-2019-7078).

  2. Author contributions: Muharrem Taşdemir: data analysis, paper writing, investigation, and methodology; Fatih Şenaslan: writing – review, editing; Ayhan Çelik: supervisor, paper writing.

  3. Conflict of interest: The authors state no conflict of interest.

References

(1) Gopi JA, Nando GB. Effect of processing parameters on phase morphology and mechanical properties of thermoplastic polyurethane and polydimethylsiloxane rubber blends. Int J Plast Technol. 2015;19(2):288–308. 10.1007/s12588-015-9109-0.Search in Google Scholar

(2) Seethapathy S, Gorecki T. Applications of polydimethylsiloxane in analytical chemistry: a review. Anal Chim Acta. 2012;750:48–62. 10.1016/j.aca.2012.05.004.Search in Google Scholar PubMed

(3) Hemmilä S, Cauich-Rodríguez JV, Kreutzer J, Kallio P. Rapid, simple, and cost-effective treatments to achieve long-term hydrophilic PDMS surfaces. Appl Surf Sci. 2012;258(24):9864–75. 10.1016/j.apsusc.2012.06.044.Search in Google Scholar

(4) Abbasi F, Mirzadeh H, Katbab AA. Modification of polysiloxane polymers for biomedical applications: a review. Polym Int. 2001;50(12):1279–87. 10.1002/pi.783.Search in Google Scholar

(5) Coelho EC, Dos Santos DP, Ciuffi KJ, Ferrari JL, Ferreira BA, Schiavon MA. Poly (vinyl alcohol) and poly (dimethylsiloxane)-based interpenetrating polymer networks via radical polymerisation. J Polym Res. 2014;21(9):561. 10.1007/s10965-014-0561-x.Search in Google Scholar

(6) Eduok U, Faye O, Szpunar J. Recent developments and applications of protective silicone coatings: a review of PDMS functional materials. Prog Org Coat. 2017;111:124–63. 10.1016/j.porgcoat.2017.05.012.Search in Google Scholar

(7) Li J, Wang M, Shen Y. Chemical modification on top of nanotopography to enhance surface properties of PDMS. Surf Coat Technol. 2012;206(8–9):2161–7. 10.1016/j.surfcoat.2011.09.052.Search in Google Scholar

(8) Hansal WE, Hansal S, Pölzler M, Kornherr A, Zifferer G, Nauer GE. Investigation of polysiloxane coatings as corrosion inhibitors of zinc surfaces. Surf Coat Technol. 2006;200(9):3056–63. 10.1016/j.surfcoat.2005.01.049.Search in Google Scholar

(9) Banerjee SS, Ramakrishnan I, Satapathy BK. Modification of polydimethylsiloxane with polyvinylpyrrolidone: influence of reinforcing filler on physico-mechanical properties. Polym Eng Sci. 2016;56(5):491–9. 10.1002/pen.24240.Search in Google Scholar

(10) Roohpour N, Wasikiewicz JM, Paul D, Vadgama P, Rehman IU. Synthesis and characterisation of enhanced barrier polyurethane for encapsulation of implantable medical devices. J Mater Sci: Mater Med. 2009;20(9):1803–14. 10.1007/s10856-009-3754-9.Search in Google Scholar PubMed

(11) Drupitha MP, Das B, Parameswaran R, Dhara S, Nando GB, Naskar K. Hybrid electrospun fibers based on TPU-PDMS and spherical nanohydroxyapatite for bone tissue engineering. Mater Today Commun. 2018;16:264–73. 10.1016/j.mtcomm.2018.06.013.Search in Google Scholar

(12) Xie J, Hu J, Lin X, Fang L, Wu F, Liao X, et al. Robust and anti-corrosive PDMS/SiO2 superhydrophobic coatings fabricated on magnesium alloys with different-sized SiO2 nanoparticles. Appl Surf Sci. 2018;457:870–80. 10.1016/j.apsusc.2018.06.250.Search in Google Scholar

(13) Qiao X, Chen R, Zhang H, Liu J, Liu Q, Yu J, et al. Outstanding cavitation erosion resistance of hydrophobic polydimethylsiloxane-based polyurethane coatings. J Appl Polym Sci. 2019;136(25):47668. 10.1002/app.47668.Search in Google Scholar

(14) Rahman MM, Hasneen A, Kim HD, Lee WK. Preparation and properties of polydimethylsiloxane (PDMS)/polytetramethyleneadipate glycol (PTAd)-based waterborne polyurethane adhesives: Effect of PDMS molecular weight and content. J Appl Polym Sci. 2012;125(1):88–96. 10.1002/app.34816.Search in Google Scholar

(15) Zong J, Zhang Q, Sun H, Yu Y, Wang S, Liu Y. Characterization of polydimethylsiloxane–polyurethanes synthesized by graft or block copolymerizations. Polym Bull. 2010;65(5):477–93. 10.1007/s00289-010-0262-5.Search in Google Scholar

(16) Sundaran SP, Reshmi CR, Sujith A. Tailored design of polyurethane based fouling-tolerant nanofibrous membrane for water treatment. N J Chem. 2018;42(3):1958–72. 10.1039/c7nj03997b.Search in Google Scholar

(17) Kim MW, Lee SH, Youn JR. Effects of filler size and content on shrinkage and gloss of injection molded PBT/PET/talc composites. Polym Compos. 2010;31(6):1020–7. 10.1002/pc.20888.Search in Google Scholar

(18) Poomali, Siddramaiah, Suresha B, Lee J-H. Mechanical and three-body abresive wear behaviour of PMMA/TPU blends. Mater Sci Eng. 2008;A492:486–90. 10.1016/j.msea.2008.03.018.Search in Google Scholar

(19) Dubey KA, Chaudhari CV, Bhardwaj YK, Varshney L. Polymers, blends and nanocomposites for implants, scaffolds and controlled drug release applications. Advances in Biomaterials for Biomedical Applications. Singapore: Springer; 2017. p. 1–44. 10.1007/978-981-10-3328-5_1.Search in Google Scholar

(20) Zhang ZP, Song XF, Cui LY, Qi YH. Synthesis of polydimethylsiloxane-modified polyurethane and the structure and properties of its antifouling coatings. Coatings. 2018;8(5):157. 10.3390/coatings8050157.Search in Google Scholar

(21) Joki-Korpela F, Pakkanen TT. Incorporation of polydimethylsiloxane into polyurethanes and characterization of copolymers. Eur Polym J. 2011;47(8):1694–1708. 10.1016/j.eurpolymj.2011.06.006.Search in Google Scholar

(22) Soldani G, Losi P, Bernabei M, Burchielli S, Chiappino D, Kull S, et al. Long term performance of small-diameter vascular grafts made of a poly (ether) urethane–polydimethylsiloxane semi-interpenetrating polymeric network. Biomaterials. 2010;31(9):2592–605. 10.1016/j.biomaterials.2009.12.017.Search in Google Scholar PubMed

(23) Rajan KP, Al-Ghamdi A, Parameswar R, Nando GB. Blends of thermoplastic polyurethane and polydimethylsiloxane rubber: assessment of biocompatibility and suture holding strength of membranes. Int J Biomater. 2013;2013:240631. 10.1155/2013/240631.Search in Google Scholar PubMed PubMed Central

(24) Ghanbari K, Ehsani M. Change in surface properties of polydimethylsiloxane/polyurethane/carbon nanotubes elastomeric coatings. Prog Org Coat. 2018;125:393–402. 10.1016/j.porgcoat.2018.09.022.Search in Google Scholar

(25) Ward B, Anderson J, Ebert M, McVenes R, Stokes K. In vivo biostability of polysiloxane polyether polyurethanes: Resistance to metal ion oxidation. J Biomed Mater Res A. 2006;77(2):380–9. 10.1002/jbm.a.30553.Search in Google Scholar PubMed

(26) Souza JC, Tajiri HA, Morsch CS, Buciumeanu M, Mathew MT, Silva FS, et al. Tribocorrosion behavior of Ti6Al4V coated with a bio-absorbable polymer for biomedical applications. J Bio- Tribo-Corros. 2015;1:27. 10.1007/s40735-015-0029-5.Search in Google Scholar

(27) Niu H, Wang H, Zhou H, Lin T. Ultrafine PDMS fibers: preparation from in situ curing-electrospinning and mechanical characterization. RSC Adv. 2014;4(23):11782–87. 10.1039/c4ra00232f.Search in Google Scholar

(28) Zhang Q, Hu J, Gong S. Preparation and characterization of aqueous polyurethane dispersions with well‐defined soft segments. J Appl Polym Sci. 2011;122(5):3064–70. 10.1002/app.34095.Search in Google Scholar

(29) Zhao H, Hao TH, Hu GH, Shi D, Huang D, Jiang T, et al. Preparation and characterization of polyurethanes with cross-linked siloxane in the side chain by sol–gel reactions. Materials. 2017;10(3):247. 10.3390/ma10030247.Search in Google Scholar PubMed PubMed Central

(30) Xia XK, Wang XH, Zhang W, Han XL, Chen P, Jiang Y. Improving the wettability and antiprotein adsorption property of PDMS by swelling–deswelling approach. J Coat Technol Res. 2019;16(2):353–61. 10.1007/s11998-018-0070-7.Search in Google Scholar

(31) Li Y, Zhao R, Li X, Wang C, Bao H, Wang S, et al. Blood-compatible polyaniline coated electrospun polyurethane fiber scaffolds for enhanced adhesion and proliferation of human umbilical vein endothelial cells. Fibers Polym. 2019;20(2):250–60. 10.1007/s12221-019-8735-0.Search in Google Scholar

(32) Zhang H, Chiao, M. Anti-fouling coatings of poly (dimethylsiloxane) devices for biological and biomedical applications. J. Med. Biol. Eng. 2015;35(2):143–55. 10.1007/s40846-015-0029-4.10.1007/s40846-015-0029-4Search in Google Scholar PubMed PubMed Central

(33) Arukalam IO, Oguzie EE, Li Y. Nanostructured superhydrophobic polysiloxane coating for high barrier and anticorrosion applications in marine environment. J Colloid Interface Sci. 2018;512:674–85. 10.1016/j.jcis.2017.10.089.Search in Google Scholar PubMed

(34) Wu Z, Tong W, Jiang W, Liu X, Wang Y, Chen H. Poly (N-vinylpyrrolidone)-modified poly (dimethylsiloxane) elastomers as anti-biofouling materials. Colloids Surf, B. 2012;96:37–43. 10.1016/j.colsurfb.2012.03.016.Search in Google Scholar PubMed

(35) Mazumder MM, De S, Trigwell S, Ali N, Mazumder MK, Mehta JL. Corrosion resistance of polyurethane-coated nitinol cardiovascular stents. J Biomater Sci, Polym Ed. 2003;14(12):1351–62. 10.1163/156856203322599699.Search in Google Scholar PubMed

(36) López-Ortega A, Arana JL, Bayón R. Tribocorrosion of passive materials: a review on test procedures and standards. Int J Corros. 2018;2018:7345346. 10.1155/2018/7345346.Search in Google Scholar

(37) Qiu H, Hölken I, Gapeeva A, Filiz V, Adelung R, Baum M. Development and characterization of mechanically durable silicone-polythiourethane composites modified with tetrapodal shaped ZnO particles for the potential application as fouling-release coating in the marine sector. Materials. 2018;11(12):2413. 10.3390/ma11122413.Search in Google Scholar PubMed PubMed Central

(38) Al-Harbi LM, Darwish MS, Khowdiary MM, Stibor I. Controlled preparation of thermally stable Fe-poly (dimethylsiloxane) composite by magnetic induction heating. Polymers. 2018;10(5):507. 10.3390/polym10050507.Search in Google Scholar PubMed PubMed Central

(39) Thomas TH, Kendrick TC. Thermal analysis of polysiloxanes. II. Thermal vacuum degradation of polysiloxanes with different substituents on silicon and in the main siloxane chain. J. Polym. Sci. Part A-2: Polym. Phys. J. 1970;8(10):1823–30. 10.1002/pol.1970.160081016.10.1002/pol.1970.160081016Search in Google Scholar

(40) Grassie N, Macfarlane IG. The thermal degradation of polysiloxanes—I. Poly (dimethylsiloxane). Eur. Polym. J. 1978;14(11):875–84. 10.1016/0014-3057(78)90084-8.10.1016/0014-3057(78)90084-8Search in Google Scholar

Received: 2021-01-04
Revised: 2021-04-14
Accepted: 2021-04-15
Published Online: 2021-05-10

© 2021 Muharrem Taşdemir et al., published by De Gruyter

This work is licensed under the Creative Commons Attribution 4.0 International License.

Downloaded on 19.4.2024 from https://www.degruyter.com/document/doi/10.1515/epoly-2021-0035/html