Skip to main content
Log in

Determination of Inductance through Capacitance using Commercial LCR Meters

  • Original Paper
  • Published:
MAPAN Aims and scope Submit manuscript

Abstract

Present work can be used to calibrate inductance standards by utilizing the error evaluated at the same nominal value of reactance of a capacitance standard. Inductance can be determined in terms of capacitance standard by direct measurement of capacitive reactance on the LCR meter. The conventional Maxwell–Wien bridge is currently used at CSIR-NPL to determine traceability to the inductance standard through capacitance and two resistance standards. However, proposed technique defines inductance in terms of one capacitance only. Measurement results of 100 mH inductors at 1 kHz are evaluated and validated with the inductor's previously assigned values with Maxwell–Wien bridge. Preliminary results obtained from both techniques were found within 50 ppm; hence this technique can be used as an alternative to Maxwell–Wien bridge.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. S.L. Dahake, R.N. Dhar, A.K. Saxena, V.K. Batra and K. Chandra, Progress in the Realization of the units of Capacitance Resistance and Inductance at the NPL India. IEEE Trans on Instrum. Meas., IM–32 (1983) 5–8.

    Article  Google Scholar 

  2. R.N. Dhar, A.K. Saxena, N. Singh, S.L. Dahake and K. Chandra, Realization of Inductance Standards with the Help of Improved Maxwell–Wien Bridge. IE (I) Journal-EL, 70 (1990) 195–198.

    Google Scholar 

  3. R.N. Dhar, A.K. Saxena, S.L. Dahake and K. Chandra, Variable Ratio Bridge for Precision Comparison of Inductors. J. Inst. Eng India, 67 (1986) 92–95.

    Google Scholar 

  4. S.L. Dahake, R.N. Dhar, A.K. Saxena, N. Singh and K. Chandra, Precision Measurement of Inductance by Maxwell–Wien Bridge and Resonance Technique. J. Inst. Eng., 65 (1995) 112–116.

    Google Scholar 

  5. R.N. Dhar, A.K. Saxena, S.L. Dahake and K. Chandra, Present Status of National Standard of Inductance and Calibration Facilities at NPL, New Delhi. ALL India Seminar on Electrical Measurements, Standardization and Calibration, Calcutta (1981).

    Google Scholar 

  6. B. Waltrip, S. Avramov-Zamurovic and A. Koffman, "Inductance Measurement Using an LCR Meter and a Current Transformer Interface, 2005 IEEE Instrumentation and Measurement Technology Conference Proceedings, Ottawa ON Canada (2005), pp. 1005-1007. https://doi.org/10.1109/IMTC.2005.1604290

  7. M. Saleem, M.A. Ansari, A.K. Saxena, N. Fletcher, R. Goebel and M. Stock, Bilateral comparison of 10 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.a) between the NPLI and the BIPM, July 2010–May 2011. Metrologia, 52 (2015) 01015–01015.

    Article  ADS  Google Scholar 

  8. M. Saleem, M.A. Ansari, A.K. Saxena, N. Fletcher, R. Goebel and M. Stock, Bilateral comparison of 100 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NPLI and the BIPM, July 2010–May 2011. Metrologia, 52 (2015) 01016.

    Article  ADS  Google Scholar 

  9. Manual of 1620 capacitance bridge. https://www.ietlabs.com/pdf/Manuals/1620_im.pdf

  10. Datasheet of 1620 capacitance bridge. https://www.ietlabs.com/pdf/Datasheets/1620.pdf

  11. M. Satish, A. Ansari and A.K. Saxena, Determination and Comparison of Temperature Coefficient of Standard Inductors by Measuring Change in Inductance and Resistances, Mapan-JMSI 29(1) (2014) 73–76

  12. M. Satish, A. Ansari and A.K. Saxena, An Automation Program for the study of Standard Inductor using LCR Meter, In Advances in Metrology (2012), p. EM010.

  13. M. Saleem, M. A. Ansari and A. K. Saxena, Study of Standard Mica Capacitors with Respect to Time and Temperature, 28(2013) 25–29.

Download references

Acknowledgment

The authors would like to thank Director CSIR-NPL, Dr. D K Aswal, for his constant support and encouragement to carry out this work.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Priyanka Jain.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jain, P., Kumar, S., Satish et al. Determination of Inductance through Capacitance using Commercial LCR Meters. MAPAN 36, 349–353 (2021). https://doi.org/10.1007/s12647-021-00444-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12647-021-00444-2

Keywords

Navigation