Confirm Suitability of the 3D Positive Ion Detector to Use in the Field of Radiation Protection, and Gamma Spectrometry Applications

  • PHYSICS OF ELEMENTARY PARTICLES AND ATOMIC NUCLEI. EXPERIMENT
  • Published:
Physics of Particles and Nuclei Letters Aims and scope Submit manuscript

Abstract

It is well known that the environmental radiation surrounding us consists of various types of radiation that could be dangerous to human health, causes air pollution and also has importance in industry and medicine. There are different types of gamma spectrometry and radiation protection technologies are available. Even though these technologies have been used for several decades; there is a need to improve the sensitivity and selectivity for these detectors. The Multilayer PCB technology based Nanodosimeter was designed to capture positive ions produced by the interaction of ionizing radiation with low pressure gas medium. In order to confirm the signal, the present signal captured under methane medium at 1 to 10 Torr pressure. The indigenously fabricated 3D positive ion detector of thickness 3.483 mm with optimized cathode was using the same Nanodosimeter experimental setup using the Co-60 source. To conform the performance of the 3D positive ion detector as gamma spectrometry and Radiation protection.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.
Fig. 6.
Fig. 7.

Similar content being viewed by others

REFERENCES

  1. ICRP, “Recommendations of the ICRP,” Ann. ICRP 1 (3) (1977).

  2. ICRP, “A compilation of the major concepts and quantities in use by ICRP,” Ann. ICRP 14 (4) (1985).

  3. ICRP, “1990 recommendations of the international commission on radiological protection,” Ann. ICRP 21 (1–3) (1991).

  4. ICRP, “The optimization of radiological protection: Broadening the process,” Ann. ICRP 36 (3), 69–87 (2006).

    Article  Google Scholar 

  5. ICRP, “The 2007 recommendations of the International Commission on Radiological Protection,” Ann. ICRP 37 (2-4) (2007).

  6. J. Baum, Occupational Exposures and Practices in Nuclear Power Plants (Brookhaven National Lab., New York, NY, USA).

  7. A. Gauvenet, “Radiation protection practices and experience in french operating reactors,” Nucl. Technol. 72, 246–253 (1986).

    Article  Google Scholar 

  8. J. Hildebrand, “Experience in the optimization of radiation protection practices during the cleanup of three mile island unit 2,” in Optimization of Radiation Protection (1986).

  9. G. Vivian and K. Donnelly, A Canadian Nuclear Power Producer’s Approach to the Optimization of Design for Radiation Protection (IAEA, 1986).

    Google Scholar 

  10. R. Wilson, G. A. Vivian, W. J. Chase, et al., “Occupational dose reduction experience in Ontario hydro nuclear power stations,” Nucl. Technol. 72, 231–245 (1986).

    Article  Google Scholar 

  11. Ocken, “Radiation dose management in nuclear power plants,” Prog. Nucl. 39, 31–51 (2001).

  12. V. Bashkirov, R. F. Hurley, and R. W. Schulte, “A novel detector for 2D ion detection in low pressure gas and its applications,” in Proceedings of the IEEE Nuclear Sci. Symposium (NSS/MIC), 2009, p. 694.

  13. M. Casiraghi, V. Bashkirov, F. Hurley, and R. Schulte, “A novel approach to study radiation track structure with nanometer-equivalent resolution,” Eur. Phys. J. D 68, 111 (2014).

    Article  ADS  Google Scholar 

  14. M. Casiraghi, V. A. Bashkirov, R. F. Hurley, and R. W. Schulte, “Characterization of atrack structure imaging detector,” Radiat. Prot. Dosim., 1–5 (2015).

  15. F. Vasi, M. Casiraghi, V. Bashkirov, U. Giesen, and R. W. Schulte, “Development of a single ion detector for radiation track structure studies,” J. Instrum. 11, C09021 (2016).

    Article  Google Scholar 

  16. P. Venkatraman and Ch. S. Sureka, “Fabrication and characterization of a 3D positive ion detector and its applications,” Nucl. Instrum. Methods Phys. Res., Sect. A 872, 131–138 (2017).

    Google Scholar 

  17. P. Venkatraman and C. S. Sureka, “An in-vitro study for early detection to and distinguish breast and lung malignancies using the PCB technology based nanodosimeter,” Sci. Rep. 9 (380), 1–16 (2019).

    Google Scholar 

  18. P. Venkatraman and C. S. Sureka, “Analysis on the performance of a 3D positive ion detector as propane and argon sensor,” Nucl. Instrum. Methods Phys. Res., Sect. B 450, 369–373 (2019).

    Google Scholar 

  19. P. Venkatraman and C. S. Sureka, “"Analyze the positive ion detector in terms of thickness,” Nucl. Instrum. Methods Phys. Res., Sect. B 450, 374–379 (2019).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Pitchaikannu Venkatraman or Chandrasekaran Senbagavadivoo Sureka.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Pitchaikannu Venkatraman, Chandrasekaran Senbagavadivoo Sureka Confirm Suitability of the 3D Positive Ion Detector to Use in the Field of Radiation Protection, and Gamma Spectrometry Applications. Phys. Part. Nuclei Lett. 18, 232–238 (2021). https://doi.org/10.1134/S1547477121020217

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1547477121020217

Navigation