Impact of Moisture on AC Breakdown Voltage of Crude, Refined and Transesterified Groundnut Oil-based Liquid Insulations

  • Research Article-Electrical Engineering
  • Published:
Arabian Journal for Science and Engineering Aims and scope Submit manuscript

Abstract

With the aim of analyzing the ability of vegetable oil-based liquid insulation as alternate medium under moisture-rich environment, this study presents an experimental analysis of impact on breakdown voltage characteristics vegetable oil-based insulating liquids for the moisture inclusion with oil sample. The study has been proposed to carry out with different categories of groundnut oil in crude form, refined form and transesterified form. The moisture inclusion range of 5 ppm to 25 ppm is considered based on the literature with the scope of having lower solubility level and less than 50% of water saturation level for avoiding wet transformer conditions. Experimental investigations have been done on AC breakdown voltage of three categories of groundnut oil for inclusion of proposed range of moisture. With an increased moisture level from 5 to 25 ppm, significant reduction in breakdown voltage of oil samples has been obtained with the average percentage of 53 to 67% which may be due to possible modification in the molecular component of oil with the influence of moisture's polarization characteristics. Based on the experimental observations, the empirical power equations developed based on the regression method to predict the approximate breakdown voltage at different moisture levels.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Okubo, H.; Beroual, A.: Recent trend and future perspectives in electrical insulation techniques in relation to sulfur hexafluoride (SF6) substitutes for high voltage electric power equipment. IEEE Electr. Insul. Mag. 27, 34–42 (2011)

    Article  Google Scholar 

  2. Fofana, I.: 50 years in the development of insulating liquids. IEEE Electr. Insul. Mag. 29, 13–25 (2013)

    Article  Google Scholar 

  3. Mehta, D.M.; Kundu, P.; Chowdhury, A.; Lakhiani, V.K.; Jhala, A.S.: A review on critical evaluation of natural ester vis-a-vis mineral oil insulating liquid for use in transformers: Part I. IEEE Trans. Dielectr. Electr. Insul. 23, 873–880 (2016)

    Article  Google Scholar 

  4. Mehta, D.M.; Kundu, P.; Chowdhury, A.; Lakhiani, V.K.; Jhala, A.S.: A review of critical evaluation of natural ester vis-a-vis mineral oil insulating liquid for use in transformers: Part II. IEEE Trans. Dielectr. Electr. Insul. 23, 1705–1712 (2016)

    Article  Google Scholar 

  5. Rafiq, M.; Lv, Y.Z.; Zhou, Y.; Ma, K.B.; Wang, W.; Li, C.R.; Wang, Q.: Use of vegetable oils as transformer oils—a review. Renew. Sustain. Energy Rev. 52, 308–324 (2015)

    Article  Google Scholar 

  6. Fernández-Diego, C.; Ortiz, A.; Fernández, I.; Carrascal, I.; Renedo, C.J.; Delgado, F.: Assessment of the effect of commercial vegetal oils on Kraft paper ageing through mechanical characterization. IEEE Trans. Dielectr. Electr. Insul. 25, 1880–1887 (2018)

    Article  Google Scholar 

  7. Mehmood, M.A.; Nazir, M.T.; Li, J.; Wang, F.; Azam, M.M.: Comprehensive investigation on service aged power transformer insulating oil after decades of effective performance in field. Arab. J. Sci. Eng. (2020). https://doi.org/10.1007/s13369-020-04559-7

    Article  Google Scholar 

  8. Rao, M.; Sood, Y.R.; Jarial, R.K.: Ester dielectrics: current perspectives and future challenges. IETE Tech. Rev. 34, 448–459 (2016)

    Article  Google Scholar 

  9. Rao, M.; Fofana, I.; Jaya, T.; Rodriguez-Celis, E.M.; Jalbert, J.; Picher, P.: Alternative dielectric fluids for transformer insulation system: progress, challenges, and future prospects. IEEE Access 7, 184552–184571 (2019)

    Article  Google Scholar 

  10. Yu, H.; Yu, P.; Luo, Y.: Renewable low viscosity dielectrics based on vegetable oil methyl esters. J. Electr. Eng. Tech. 12, 820–829 (2017)

    Article  Google Scholar 

  11. Jaikumar, S.; Bhatti, S.K.; Srinivas, V.: Experimental investigations on performance, combustion, and emission characteristics of niger (Guizotia abyssinica) seed oil methyl ester blends with diesel at different compression ratios. Arab. J. Sci. Eng. 44, 5263–5273 (2019)

    Article  Google Scholar 

  12. Abdi, S.; Safiddine, L.; Boubakeur, A.; Haddad, A.: The effect of water content on the electrical properties of transformer oil. In: Lect Notes Electr Eng, 599, Springer, (2020)

  13. Wang, D.; Zhou, L.; Wang, A.; Li, H.: Effects of thermal aging on moisture diffusion in insulation paper immersed with mineral oil. IEEE Trans. Dielectr. Electr. Insul. 25, 1888–1896 (2018)

    Article  Google Scholar 

  14. Suleiman, A.A.; Muhamad, N.A.; Bashir, N.; Murad, N.S.; Arief, Y.Z.; Phung, B.T.: Effect of moisture on breakdown voltage and structure of palm based insulation oils. IEEE Trans. Dielectr. Electr. Insul. 21, 2119–2126 (2014)

    Article  Google Scholar 

  15. Martin, D.; Wang, Z.; Darwin, A.; James, I.: A comparative study of the chemical stability of esters for use in large power transformers. In: IEEE Conf. Electr. Insul. Dielectr. Pheno. (ICEIDP), pp. 493–496 (2006)

  16. Campbell, M.K.; Farrell, S.O.: Biochemisrty, 5th edn. Thomson Brooks/Cole, USA (2006)

    Google Scholar 

  17. Buell, P.; Girard, J.E.: Chemistry Fundamentals: An Environmental Perspective, 2nd edn. Jones and Bartlett Learning, USA (2003)

    Google Scholar 

  18. Dakin, W.: Conduction and polarization mechanisms and trends in dielectric. IEEE Electr. Insul. Mag. 22, 11–28 (2006)

    Article  Google Scholar 

  19. CIGRE WG17.12: Effect of particles on transformer dielectric strength. Working Group 17 of Study Committee 12, CIGRE (2000)

  20. Sivaprakasam, S.; Saravanan, C.G.: Optimization of the transesterification process for biodiesel production and use of biodiesel in a compression ignition engine. Energy Fuels 21, 2998–3003 (2007)

    Article  Google Scholar 

  21. Liu, Y.; Kujawinski, E.B.: Chemical composition and potential environmental impacts of water soluble polar crude oil components inferred from ESI FT-ICR MS. PLoS One 10, e0136376 (2015)

    Article  Google Scholar 

  22. Bakrutheen, M.; Willjuice, I.M.; Narayani, A.: Statistical failure reliability analysis on edible and non edible natural esters based liquid insulation for the applications in high voltage transformers. IEEE Trans. Dielectr. Electr. Insul. 25, 1579–1586 (2018)

    Article  Google Scholar 

  23. Lewand, L: Understanding water in transformer systems—The relationship between relative saturation and parts per million (ppm). Chemist's perspective, Springer.1–4, (2002)

  24. Buerschaper, B.; Kleboth-Lugova, O.; Liebfried, T.: The electrical strength of transformer oil in a transformerboard-oil system during moisture non-equilibrium. In: IEEE Conf. Elect. Insul. Dielect. Phen. 269–272, (2003)

  25. IEC 60156–11: Insulating liquids—Determination of the breakdown voltage at power frequency—Test method. 3rd ed., IEC Standard. (2018)

  26. IEEE C57.147: IEEE Guide for acceptance and maintenance of natural ester insulating liquid in transformers. IEEE Standard, IEEE Power and Energy Society, Newyork, USA (2018)

  27. Ghani, S.A.; Muhamad, N.A.; Chairul, I.S.; Jamri, N.: A study of moisture effects on the breakdown voltage and spectral characteristics of mineral and palm oil-based insulation oils. ARPN J. Eng. Appl. Sci. 11, 5012–5020 (2016)

    Google Scholar 

  28. Bakrutheen, M.; Willjuice Iruthayarajan, M.; Narayani, A.: Influence of ultrasonic waves on viscosity of edible natural esters based liquid insulation. IEEE Trans. Dielectr. Electr. Insul. 25, 1628–1635 (2018)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Bakrutheen.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ajmal Ahamed, S., Mohamed Riyaz, S., Mahadevan, A. et al. Impact of Moisture on AC Breakdown Voltage of Crude, Refined and Transesterified Groundnut Oil-based Liquid Insulations. Arab J Sci Eng 46, 9763–9770 (2021). https://doi.org/10.1007/s13369-021-05543-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13369-021-05543-5

Keywords

Navigation