Skip to main content
Log in

Calibration and parameter corrections for the new generation of the TSI monitor on the FY-3E satellite

  • Original Article
  • Published:
Astrophysics and Space Science Aims and scope Submit manuscript

A Correction to this article was published on 26 August 2022

This article has been updated

Abstract

In order to support the analysis of potential long-term trends in the Sun’s variability and trace the WRR ground calibration ratio to the measurement on the satellite. We established the total solar irradiance (TSI) calibration model in orbit for the new generation of solar radiation monitor on the FY-3E satellite. First, we measured the non-equivalence of the instrument, and the air to vacuum ratio of the SIAR radiometer is 0.9958-0.9973. Then, we established the temperature correction model for the important parameters, such as the aperture area, the standard voltage and the heating wire resistance. Finally, we calibrated the SIAR with the world radiation reference (WRR) and traced the ground calibration result to the measurement on the satellite. The end-to-end calibration ratio is 0.9991-1.0006, and the uncertainties for three channels are all better than 0.08%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

Change history

References

Download references

Author information

Authors and Affiliations

Authors

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

The original version of this article has been revised: Figs. 4 and 5 have been corrected.

Rights and permissions

Springer Nature or its licensor holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Song, B., Finsterle, W., Ye, X. et al. Calibration and parameter corrections for the new generation of the TSI monitor on the FY-3E satellite. Astrophys Space Sci 366, 27 (2021). https://doi.org/10.1007/s10509-021-03932-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s10509-021-03932-8

Keywords

Navigation