Skip to main content
Log in

Application of the LaCl3(Ce) Scintillator to Fast Neutron Measurements

  • NEUTRON PHYSICS
  • Published:
Physics of Particles and Nuclei Letters Aims and scope Submit manuscript

Abstract

Most modern magnetic confinement fusion devices feature deuterium plasma with the emission of 2.5 MeV neutrons. The neutron yield during the discharge gives information on plasma heating and confinement efficiency. Hence, the challenge of measuring a fast DD neutron flux becomes an increasingly important task for fusion research. This work studies the possibility of using a LaCl3(Ce) scintillation crystal for this. The scintillation detector characteristics were studied using reference γ sources and a ING-07D fast-neutron generator with a neutron yield of up to 1 × 107 n/s. The GEANT4 code was used for the numerical modeling of the detector response to neutron and γ irradiation. The results provide a promising outlook for the application of a LaCl3(Ce) crystal for the purposes of fast DD neutron measurements.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.
Fig. 6.
Fig. 7.
Fig. 8.
Fig. 9.
Fig. 10.
Fig. 11.

Similar content being viewed by others

REFERENCES

  1. G. G. Knoll, Radiation Detection and Measurement, 4th ed. (Wiley, New York, 2010).

    Google Scholar 

  2. A. Giaz, N. Blasi, C. Boiano, S. Brambilla, F. Camera, C. Cattadori, S. Ceruti, F. Gramegna, T. Marchi, I. Mattei, A. Mentana, B. Million, L. Pellegri, M. Rebai, S. Riboldi, F. Salamida, and M. Tardocchi, “Fast neutron measurements with 7Li and 6Li enriched CLYC scintillators,” Nucl. Instrum. Meth. Phys. Res., Sect. A 825, 51 (2016).

    Google Scholar 

  3. D. A. Brown, M. B. Chadwick, R. Capote, A. C. Kahler, A. Trkov, M. W. Herman, A. A. Sonzogni, Y. Danon, A. D. Carlson, M. Dunn, D. L. Smith, G. M. Hale, G. Arbanas, R. Arcilla, C. R. Bates, et al., “ENDF/B-vIII.0: The 8th major release of the nuclear reaction data library with CIELO-project cross sections, new standards and thermal scattering data,” Nucl. Data Sheeets 148, 1–142 (2018).

    Article  ADS  Google Scholar 

  4. W. Wolszczak and P. Dorenbos, “Shape of intrinsic alpha pulse height spectra in lanthanide halide scintillators,” Nucl. Instrum. Methods Phys. Res., Sect. A 857, 66–74 (2017).

    Google Scholar 

  5. J. Allison, K. Amako, J. Apostolakis, P. Arce, M. Asai, T. Aso, E. Bagli, A. Bagulya, S. Banerjee, G. Barrand, B. R. Beck, A. G. Bogdanov, D. Brandt, J. M. C. Brown, H. Burkhardt, et al., “Recent developments in GEANT4,” Nucl. Instrum. Methods Phys. Res., Sect. A 835, 186–225 (2016).

    Google Scholar 

Download references

Funding

This work was supported by State Contract of December 26, 2018, no. Н.4а.241.19.19.1009.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to T. Kormilitsyn.

Additional information

Translated by E. Baldina

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kormilitsyn, T., Obudovsky, S., Kashchuk, Y. et al. Application of the LaCl3(Ce) Scintillator to Fast Neutron Measurements. Phys. Part. Nuclei Lett. 18, 75–81 (2021). https://doi.org/10.1134/S154747712101009X

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S154747712101009X