Skip to main content
Log in

Herbert Hardness Test Using Accelerometer for Swing Angle Detection

  • Brief technical note
  • Published:
Experimental Techniques Aims and scope Submit manuscript

Abstract

A Herbert pendulum hardness tester can measure the hardness of a sample with a complex shape, such as a drill bit. Hardness is evaluated based on the free decay curve of the Herbert pendulum in the hardness test. The accuracy of a conventional Herbert hardness test is low because the swing of the pendulum is measured using a level gauge attached to the pendulum. The authors previously proposed a Herbert hardness tester that comprises a Herbert pendulum and two laser displacement sensors for swing angle detection. In this study, to increase portability, an accelerometer is used for swing angle detection. A prototype of the proposed Herbert pendulum equipped with an accelerometer is fabricated and its accuracy is evaluated. The damping hardness accuracy of the prototype Herbert hardness tester is equivalent to that of the previously proposed tester. The results show that using an accelerometer for swing angle detection reduces size, weight, and cost of a Herbert pendulum hardness tester without decreasing accuracy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

References

  1. Yamamoto T, Yamamoto M, Watanabe M (2018) Trial of low-temperature and high-temperature hardness testing using the small-ball rebound test eNM3A10. J Phys Conf Ser 1065(6):062002

    Article  Google Scholar 

  2. Sugawara T, Nakashima S, Shimizu A, Tagami J, Momoi Y (2015) Evaluation of a new hardness tester (Cariotester): comparison with transverse microradiography for assessing the inhibitory effect of fluoride application on bovine root dentin demineralization. Dent Mater J 34(3):371–378

    Article  CAS  Google Scholar 

  3. Meier J, Tsalicoglou I, Mennicke R, Frehner C, Proceq SA (2018) The future of NDT with wireless sensors, AI and IoT. Proceedings of 15th Asia Pacific Conference for Non-Destructive Testing, Singapore

  4. Suzuki R, Halama R, Inoue Y, Nakamura M, Kaburagi T, Fujimoto H, Maruhashi H, Hagiwara T, Matsubara M (2017) Hardness evaluation of knife edge with Herbert hardness test (in Japanese). J Mater Test Res Assoc Japan 62(4):216–220

    Google Scholar 

  5. Herbert EG (1923) Some recent developments in hardness testing. Engineer 135:686–687

    Google Scholar 

  6. Suzuki R, Kaburagi T, Setagawa T, Matsubara M (2016) Evaluation of hardness of metals and nonmetals using Herbert hardness tester (in Japanese). Proceedings of the Materials and Mechanics Conference Tokyo, Japan

  7. Matsubara M, Skamoto K (2012) Improved Herbert Hardness Tester. Exp Tech 36(3):1–4

    Article  Google Scholar 

  8. Suzuki R, Kaburagi T, Matsubara M, Tashiro T, Koyama T (2016) Hardness measurement for metals using lightweight Herbert pendulum hardness tester with cylindrical indenter. Exp Tech 40(2):795–802

    Article  Google Scholar 

  9. Halama R, Podešva J, Suzuki R, Masaaki M, Čech R (2017) Mechanics of Herbert pendulum hardness tester and its application. Key Eng Mater 741:122–127

    Article  Google Scholar 

  10. Oishi M, Kubota Y, Mochizuki O (2019) Investigation of the fragmentation process of clods in a Rod Mill developed for research use. World J Mech 9(10):233–243

    Article  Google Scholar 

  11. Jegede O, Fujita K, Nagai H (2019) Development of free flight experimental and analytical procedures for atmospheric entry vehicles. Proceedings of 2019 American Institute of Aeronautics and Astronautics SciTech Forum, California USA

  12. Zhao N (2010) Full-featured pedometer design realized with 3-Axis digital accelerometer. Analog Dialogue 44(06):1–5

    Google Scholar 

  13. Cheng P, Oelmann B (2010) Joint-angle measurement using accelerometers and gyroscopes—a survey. IEEE Trans Instrum Meas 59(2):404–414

    Article  Google Scholar 

  14. Matsubara M, Nakamura M, Suzuki R (2020) Proposal for new hardness concept using Herbert hardness tester. Proceedings of the 8th International Conference on Fracture Fatigue and Wear FFW1077, Online Conference

Download references

Acknowledgments

This research was supported by the Amada Foundation (AF-2017012).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. Suzuki.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Suzuki, R., Kaburagi, T., Maruhashi, H. et al. Herbert Hardness Test Using Accelerometer for Swing Angle Detection. Exp Tech 45, 695–699 (2021). https://doi.org/10.1007/s40799-021-00438-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s40799-021-00438-4

Keywords

Navigation