Skip to main content

Advertisement

Log in

Development of patient specific dental implant using 3D printing

  • Original Research
  • Published:
Journal of Ambient Intelligence and Humanized Computing Aims and scope Submit manuscript

Abstract

In the last few years, the mixture of nuclear medicine and the reverse engineering method has confirmed to be an identical key development in the medical field. In contrast, the traditional method has some downsides. For instance, some difficulty presence in matching the well suitable due to the change of patient’s oral state and it takes more attention to meet reliability and comfort. So, the patient-specific prosthesis is required. An additional crucial problem of the patient-specific dental prosthesis is a fabrication method. The prosthesis in dental application is hard to fabricate owing to the multifaceted structures and base material. By the way of ever-growing demands for accuracy, complexity and skin-tight tolerance, traditional methods have turn into unsuccessful for machining them. This paper introduces a methodology for the computer-aided design and additive layer manufacturing of the patient-specific dental implant body for the rehabilitation of teeth. A 3Dimensional model of the dental imperfection is created while the acquirement of helical computed tomography scanning data. Then simulation is made over through software Carestream Dental. Finally, the implant is fixed into the patient’s tooth and the healing phase goes up to 3–6 months depending upon the patient. Then the crown is being fitted. During the healing phase to check the implant’s primary stability, implant stability quotient is checked. The values must be greater than or equal to 50 to attain primary stability. The medical practice exhibited that digital manufacturing and back-engineering software are outstanding mixtures of traits for dental devices designed to withstand tremendous masticatory forces and offer much more flexibility with the customized implant.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

References

  • Alghazzawi TF, Lemons J, Liu PR, Essig ME, Bartolucci AA, Janowski GM (2012) Influence of low temperature environmental exposure on the mechanical properties and structural stability of dental zirconia. J Prosthodont 21:363–369

    Article  Google Scholar 

  • Ananth H, Kundapur V, Mohammed HS, Anand M, Amarnath GS, Mankar S (2015) A review on biomaterials in dental implantology. Int J Biomed Sci 11(3):113–120

    Google Scholar 

  • Anitua E, Tapia R, Luzuriaga F, Orive G (2010) Influence of implant length, diameter, and geometry on stress distribution: a finite element analysis. Int J Periodontics Restor Dent 30:89–95

    Google Scholar 

  • Attar H, Calin M, Zhang LC, Scudino S, Eckert J (2014) Manufacture by elective laser melting and mechanical behaviour of commercially pure titanium. Mater Sci Eng A 593:170–177

    Article  Google Scholar 

  • Balaji BS, Balakrishnan S, Venkatachalam K, Jeyakrishnan V (2020) Automated query classification based web service similarity technique using machine learning. J Ambient Intell Human Comput. https://doi.org/10.1007/s12652-020-02186-6

    Article  Google Scholar 

  • Basha AJ, Balaji BS, Poornima S, Prathilothamai M, Venkatachalam K (2020) Support vector machine and simple recurrent network based automatic sleep stage classification of fuzzy kernel. J Ambient Intell Human Comput. https://doi.org/10.1007/s12652-020-02188-4

    Article  Google Scholar 

  • Berner S, Dard M, Gottlow J, Molenberg A, Wieland M (2009) Titanium zirconium: a novel material for dental implants. Eur Cells Mater 17(16):189–205

    Google Scholar 

  • Chen X, Xie L, Chen J, Du R, Deng F (2012) Design and fabrication of custom-made dental implants. J Mech Sci Technol 26(7):1993–1998

    Article  Google Scholar 

  • Cheng YY, Cheung WL, Chow TW (2010) Strain analysis of maxillary complete denture with three dimensional finite element method. J Prosthet Dent 103:309–318

    Article  Google Scholar 

  • Chou H-Y, Jagodnik JJ, Müftü S (2008) Predictions of bone remodeling around dental implant systems. J Biomech 41:1365–1373

    Article  Google Scholar 

  • Eraslan O, Inan O (2010) The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis. Clin Oral Investig 14:411–416

    Article  Google Scholar 

  • Figliuzzi M, Mangano F, Mangano C (2012) A novel root analogue dental implant using CT scan and CAD/CAM: selective laser melting technology. Int J Oral Maxillofac Surg 41:858–862

    Article  Google Scholar 

  • Gallas MM, Abeleira MT, Fernandez JR, Burguera M (2005) Three-dimensional numerical simulation of dental implants as orthodontic anchorage. Eur J Orthod 27:12–16

    Article  Google Scholar 

  • Ghuneim WA (2013) In situ tooth replica custom implant: a 3D finite element stress and strain analysis. J Oral Implantol 39:559–573

    Article  Google Scholar 

  • Hansson S, Werke M (2003) The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a Finite element study. J Biomech 36:1247–1258

    Article  Google Scholar 

  • Hopkinson N, Dickens P (1996) Analysis of rapid manufacturing-using layer for manufacturing processes production. Proc IMechE Part B J Eng Manuf 217:31–39

    Article  Google Scholar 

  • Kong L, Sun Y, Hu K, Li D, Hou R, Yang J, Liu BB (2008) Bivariate evaluation of cylinder implant diameter and length: a three-dimensional finite element analysis. J Prosthodont 17:286–293

    Article  Google Scholar 

  • Las Casas EB, Ferreira PC, Cimini CA, Toledo EM, Barra LP, Cruz M (2008) Comparative 3D finite element stress analysis of straight and angled wedge-shaped implant designs. Int J Oral Maxillofac Implants 23:215–225

    Google Scholar 

  • Lee J, Frias V, Lee K, Wright RF (2004) Effect of implant size and shape on implant success rates: a literature review. J Prosthet Dent 4(4):377–381

    Article  Google Scholar 

  • Mangano FG, Cirotti B, Sammons RL, Mangano C (2012) Custom-made, root-analogue direct laser metal forming implant: a case report. Lasers Med Sci 27:1241–1245

    Article  Google Scholar 

  • Martinez H, Davarpanah M, Missika P, Celletti R, Lazzara R (2001) Optimal implant stabilization in low density bone. Clin Oral Implants Res 12:423–432

    Article  Google Scholar 

  • Miyamoto I, Tsuboi Y, Wada E, Suwa H, Iizuka T (2005) Influence of cortical bone thickness and implant length on implant stability at the time of surgery—clinical, prospective. Biomech Imaging Study 37:776–780

    Google Scholar 

  • Ochi S, Morris H, Winkler S (1994) The influence of implant type, material, coating, diameter, and length on Periotest values at second-stage surgery. DICRG interim report No. 4. Dental Implant Clinical Research Group. Implant Dent 3:159–162

    Article  Google Scholar 

  • Osman RB, Swain MV (2015) A critical review of dental implant materials with an emphasis on titanium versus zirconia. Materials 8:932–958

    Article  Google Scholar 

  • Sagomonyants KB, Jarman-Smith ML, Devine JN, Aronow MS, Gronowic GA (2007) The in vitro response of human osteoblasts to polyetheretherketone (PEEK) substrates compared to commercially pure titanium. Biomaterials 24:3115–3123

    Google Scholar 

  • Shaw MC (2004) Metal cutting principle. Oxford series on advanced manufacturing, US

    Google Scholar 

  • Silva NR, Witek L, Coelho PG, Thompson VP, Rekow ED, Smay J (2011) Additive CAD/CAM process for dental prostheses. J Prosthodont 20:93–96

    Article  Google Scholar 

  • Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H (2003) Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 18:357–368

    Google Scholar 

  • Tunchel S, Blay A, Kolerman R, Mijiritsky E, Shibli JA (2016) 3D printing/additive manufacturing single titanium dental implants: a prospective multicenter study with 3 years of follow-up. Int J Dent 2016:1–9

    Article  Google Scholar 

  • Turkyilmaz I (2005) Influence of bone density on implant stability parameters and implant success: a retrospective clinical study. BMC Oral Health 8(32):1–8

    Google Scholar 

  • Venkatachalam K, Devipriya A, Maniraj J, Sivaram M, Ambikapathy A, Amiri IS (2020) A novel method of motor imagery classification using EEG signal. J Artif Intell Med 103:101787

    Article  Google Scholar 

  • Wang L, Sadler P, Breeding LC, Dixon DL (2007) An in vitro study of Implant-tooth supported connections using a Robot test system. J Biomech Eng 121(3):290–297

    Article  Google Scholar 

  • Yasoda K, Ponmagal RS, Bhuvaneshwari KS, Venkatachalam K (2020) Automatic detection and classification of EEG artifacts using fuzzy kernel SVM and wavelet ICA (WICA). Soft Comput. https://doi.org/10.1007/s00500-020-04920-w

    Article  Google Scholar 

  • Yoon Y, Sun X, Huang JK, Hou G, Rechowicz K, McKenzie FD (2013) Designing natural-tooth-shaped dental implants based on soft-kill option optimization. Comput Aided Des Appl 10:59–72

    Article  Google Scholar 

  • Zhou L (2009) Progress of dental implantology. West China J Stomatol 27(1):8–12

    Google Scholar 

  • Zhuang HB, Pan MC (2010) Irregular bone defect detection and device on dental Implants. J Medi Dev 4(2):27521

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. Balamurugan.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Balamurugan, P., Selvakumar, N. Development of patient specific dental implant using 3D printing. J Ambient Intell Human Comput 12, 3549–3558 (2021). https://doi.org/10.1007/s12652-020-02758-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12652-020-02758-6

Keywords

Navigation