Skip to main content
Log in

Detection, Acquisition and Processing of Fluorescence from Cold Atoms in Cesium Fountain Primary Frequency Standard at NPL, India

  • Original Paper
  • Published:
MAPAN Aims and scope Submit manuscript

Abstract

In this paper, detailed geometry of the detection chamber, configuration of detection probe laser beams, data acquisition and processing techniques of the cold atoms in Cs atomic fountain primary standard at NPL, India has been discussed. The S/N ratio in the detected atom count was too low to make a valid estimate of signal. By implementing an efficient design of detection hardware (especially changing photodiode with lower junction capacitance) and software, the S/N ratio in NPLI-CsF1 has been improved significantly (~ 10 times). Details of the detection hardware and software used for better processing of the signal are given in this paper. This paper also depicts the precise computer control for data processing and the improvements in signal to noise ratio in the context of fountain operation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13

Similar content being viewed by others

References

  1. R. Wynands and S. Weyers, Atomic fountain clocks. Metrologia 42 (2005) S64–S79.

    Article  ADS  Google Scholar 

  2. C. Vian, P. Rosenbusch, H. Marion, S. Bize, L. Cacciapuoti, S. Zhang, M. Abgrall, D. Chambon, I. Maksimovic, P. Laurent and G. Santarelli G, BNM-SYRTE fountains: recent results. IEEE Trans. Instrum. Meas. 54 (2005) 833–836.

    Article  Google Scholar 

  3. S. Weyers, U. Hübner, R. Schröder , C. Tamm and A. Bauch, Uncertainty evaluation of the atomic caesium fountain CSF1 of the PTB. Metrologia 38 (2001) 343–352.

  4. S. Weyers, A. Bauch, R. Schröder and C. Tamm, in The Atomic Caesium Fountain CSF1 of Ptb. ed. by G. Patrick. 2002 proceedings of 6th symposium on frequency standards and metrology (St Andrews, UK, 2002) pp 64–71.

  5. T. P. Heavner, S. R. Jefferts, E. A. Donley, J. H. Shirley and T. E. Parker, NIST-F1: recent improvements and accuracy evaluations. Metrologia 42 (2005) 411–422.

    Article  ADS  Google Scholar 

  6. F. Levi, D. Calonico, L. Lorini and A. Godone, IEN-CsF1 primary frequency standard at INRIM: accuracy evaluation and TAI calibrations. Metrologia 43 (6), (2006) 545–555.

    Article  ADS  Google Scholar 

  7. K. Szymaniec, W. Chalupczak, P. B. Whibberley, S. N. Lea and D. Henderson, Evaluation of the primary frequency standard NPL-CsF1. Metrologia 42 (2005) 49–57.

    Article  ADS  Google Scholar 

  8. T. Kurosu, Y. Fukuyama, Y. Koga and K. Abe, Preliminary evaluation of the Cs atomic fountain frequency standard at NMIJ/AIST. IEEE Trans. Instrum. Meas. 53 (2004) 466–471.

    Article  Google Scholar 

  9. M. Kumagai, H. Ito, M. Kajita and M. Hosokawa, Evaluation of caesium atomic fountain NICT-CsF1. Metrologia 45 (2008) 139–148.

    Article  ADS  Google Scholar 

  10. A. Sen Gupta, P. Arora, A. Agarwal and K. Pant, Development of cesium fountain frequency standard at the National Physical Laboratory, India. Curr. Sci. 100 (2011) 1393.

  11. P. Arora, S. B. Purnapatra, A. Acharya, A. Agarwal, S. Yadav, K. Pant and A. Sen Gupta, NPLI cesium atomic fountain frequency standard: preliminary results. IEEE Trans. Instrum. Meas. 62 (7), (2013) 2037–2042.

  12. G. Santarelli, Ph. Laurent, P. Lemonde, A. Clairon, A. G. Mann, S. Chang, A. N. Luiten and C. Salomon, Quantum projection noise in an atomic fountain: a high stability cesium frequency standard. Phys. Rev. Lett. 82 (23) (1999) 4619.

  13. A. Acharya, V. Bharath, P. Arora, S. Yadav, A. Agarwal and A. Sengupta, Systematic uncertainty evaluation of the cesium fountain primary frequency standard at NPL India. MAPAN-J. Metrol. Soc India, https://doi.org/10.1007/s12647-016-0190-4 (2016).

    Article  Google Scholar 

  14. K. Pant, P. Arora, S. Yadav and A. Sen Gupta, Generation of quadrupole magnetic field for trapping atoms in cs fountain being developed at NPL India. MAPAN-J. Metrol. Soc India. 26 (2011) 285.

  15. A. Clairon, S. Ghezali, G. Santarelli, Ph. Laurent, S. N. Lea, M. Bahoura, E. Simon, S. Weyers and K. Szymaniec, 1996 proceedings of 5th symposium on frequency standards and metrology (Woods Hole, MA) pp 45–59.

  16. E. W. Weisstein, Gaussian elimination. From MathWorld–A Wolfram Web Resource. http://mathworld.wolfram.com/GaussianElimination.html.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Aishik Acharya.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Acharya, A., Arora, P., Yadav, S. et al. Detection, Acquisition and Processing of Fluorescence from Cold Atoms in Cesium Fountain Primary Frequency Standard at NPL, India. MAPAN 35, 521–530 (2020). https://doi.org/10.1007/s12647-020-00405-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12647-020-00405-1

Keywords

Navigation