1 Introduction

The traditional seismic design is based on structural ductility, generally causing the development of excessive displacements that might lead to structural and non-structural damage after moderate or severe earthquakes (Di Cesare et al. 2014a). Recent advancement in earthquake engineering has led to the development of seismic resilient construction technologies that employ passive control systems to withstand strong earthquakes with limited structural damages (Ríos-García and Benavent-Climent 2020). A number of successful building projects utilizing mass-timber components is spreading in recent years thanks to their optimal strength-weight ratio, with important economic, social, environmental benefits and reduced construction time (Loss et al. 2018; Ugalde et al. 2019). Among the various structural low-damage solutions for medium and high-rise multi-storey timber buildings located in high seismic risk area, moment-resistant timber frame (Polocoșer et al. 2018), platform frame or cross laminated timber (CLT) constructions (Ceccotti et al. 2013; Van de Lindt et al. 2018; Masaeli et al. 2020; Chen et al. 2020) are emerging. Particular interest is being received worldwide by the post-tensioned timber (Pres-Lam) system, recognized as one of most effective solutions for achieving seismic-resilient and sustainable buildings.

The Pres-Lam concept was originally proposed at the University of Canterbury (UoC) in New Zealand (Palermo et al. 2005) and derives from the low-damage design of reinforced concrete structures (PREcast Seismic Structural System—PRESS) started by Priestley (1991). The technology used unbonded post-tensioned steel tendons or bars to join together structural members of timber frames or walls, creating a moment resisting connection (Buchanan et al. 2011). Due to the considerable stress induced in timber members by post-tensioning, the technology finds its application within engineered wood materials, such as laminated veneer lumber (LVL), glue-laminated timber (glulam), and cross-laminated timber (CLT). In high seismic areas the post-tensioning is usually combined with energy dissipating devices. Based on capacity design principles, the controlled rocking mechanisms of elastic post-tensioning provide self-centering action to eliminate residual drifts, while additional dissipative devices, such as replaceable steel fuses, increase the damping and reduce lateral displacements of multi-storey buildings.

Over the last years extensive experimental testing on the seismic performance of Pre-Lam frames, walls or a combination of these, has been performed and used in real building projects (Granello et al. 2020). Testing on post-tensioned beam-column joints with and without internal or external dissipative dampers showed that the systems were capable to sustain large drift demands with good re-centering capability and the addition of devices provided significant supplemental damping to the system (Palermo et al. 2005; Smith et al. 2014). Quasi static testing has been performed on Pres-Lam wall subassemblies, such as single LVL (Sarti et al. 2015a) and CLT walls (Ho et al. 2016) with elastoplastic dampers at the rocking interface, coupled walls with U-shaped flexural plates (UFP) dissipaters among them (Iqbal et al. 2017), single and coupled CLT rocking walls with UFP dissipaters (Ganey et al. 2017), coupled column-walls with UFPs (Sarti et al. 2015b). All experimental results showed a complete re-centering capability of post-tensioned walls, demonstrating the effectiveness of the system with dissipative dampers in minimizing the uplift forces on the floor with limited damages to the system. A few seismic tests on Pres-Lam building specimens have been performed in New Zealand (Newcombe et al. 2010), United States (Pei et al. 2019) and Italy (Di Cesare et al. 2017; Ponzo et al. 2019).

Newcombe et al. (2010) tested a 2/3-scale two-story LVL post-tensioned specimen by applying quasi-static loads. The structure was made of post-tensioned frames in one direction and post-tensioned walls in the other. The experimental results showed fully re-centering and no significant damage up to 2% of drift. Pei et al. (2019) conducted a full-scale shake table test of a two-story mass timber building with post-tensioned CLT rocking walls at the University of California San Diego. The results showed the resilience of CLT rocking-wall system with a heavy-timber gravity system up to the MCE and validated the low-damage characteristics of different key connection details. Moreover, it was observed that the natural period of these buildings is relatively long for the given building height and post-tensioning losses of about 8% were observed for large earthquakes. Stiffness and deformation are likely to control the design for taller building implementations. In both cases, the systems were essentially damage free up to 2% of drift, while drift values higher than 3% caused fractures of the rocking wall corners (Pei et al. 2019) or cracking in columns and slabs due to high stress concentration around dissipative anchorages (Newcombe et al. 2010).

Di Cesare et al. (2017) tested a 2/3 scale three-story post-tensioned frame specimen made of glulam timber, widely used in Europe, on the shake table at the University of Basilicata (UNIBAS, Italy) with and without supplemental dissipative rocking mechanisms. The dissipative-rocking impacts on the seismic response by increasing the equivalent viscous damping and reducing maximum drift of approximately 30%. No damage was observed on the main structural elements up to drift values of over 3%. The development of the Pres-Lam technology with additional dampers has led to the application of such systems in real building projects in many countries (Granello and Palermo 2020; Leyder et al. 2015; Kirstein et al. 2018).

In this study the resilient seismic performance of Pres-Lam buildings has been improved by coupling post-tensioned frame with dissipative bracing systems allowing a more flexible architectural configuration respect to heavy-timber gravity-framing systems combined with cross-laminated timber (CLT) walls or post-tensioned rocking walls. The dissipative bracing systems included dissipative devices able to dissipate large amounts of energy during a strong seismic event, significantly reducing the inter-storey drifts and regularizing also the structure (Ponzo et al. 2019), due to the additional stiffness and damping provided to the structural system. In case of moderate earthquakes, the system remained elastic until the fixed yielding level of damper was reached. The use of external dampers ensures that in case of eventual permanent damage after strong earthquakes, they can be replaced allowing the structure to remain operational, increasing the seismic resilience of the building.

Experimental testing and results of the 3-story post-tensioned timber frame specimen with dissipative bracing systems presented in this paper are part of an extensive experimental campaign performed at the structural laboratory of UNIBAS, in collaboration with UoC (Smith et al. 2014; Di Cesare et al. 2017), in which the bare post-tensioned frame was alternatively combined with two different form of energy dissipation. The structure was subjected to more than 100 tests considering a set of seven natural earthquakes, properly scaled at various peak ground acceleration in order to investigate from a Service Level Earthquake (SLE) to a Design Base Earthquake (DBE). The objective of the shaking table tests is to examine the seismic response of the braced post-tensioned frame at large-scale with connection details similar to those necessary for implementation in practice. For this aim, the experimental results of the braced frame in terms of inter-storey drifts, storey displacements and accelerations and base shear are compared with that of the bare post-tensioned frame with and without dissipative rocking.

2 Experimental testing

2.1 Experimental model and design configurations

The experimental specimen was a 3-D, 3-storey post-tensioned timber frame characterized by single bays in both directions. The geometry of the 2/3 scaled test specimen, 2 m inter-storey height and 4 m × 3 m in plant (Ponzo et al. 2012), was determined based on several aspects including the limitation of shake table available at the structural laboratory of the University of Basilicata. The testing frame realized using glulam grade GL32h (CNR-DT 206 2018) was post-tensioned in both directions with steel bars crossing at the beam-column joints. The flooring consisted of 150 mm thick solid timber panels. The columns of the building frame were continuous through the floor diaphragms. The prototype model was designed according to European code (UNI EN 1998-1 2013) for office use at first and second floors (live load of Q = 3 kPa) and considering a rooftop garden load (Q = 2 kPa). The seismic demand was characterized by a peak ground acceleration (PGA) of 0.44 g and a medium soil class. Observing the Cauchy-Froude similitude laws (Krawinkler and Moncarz 1981) suitable scale factors were applied to the prototype model. The additional masses due to scaling of dead load and live load were made up of concrete blocks and steel hold downs.

The dimensions of the structural elements, post-tensioning and dissipative devices were designed according to the displacement-based design procedure proposed by Priestley et al. (2007) and optimized for post-tensioned timber framed buildings with passive energy dissipation systems (Di Cesare et al. 2019a; Ponzo et al. 2019). The Modified Monolithic Beam Analogy (MMBA) procedure (Newcombe et al. 2008) was used for dimensioning the post-tensioned beam-column and column foundation connections. The resulting hysteretic response of the equivalent model is represented by the flag-shape behaviour (Fig. 1). The equivalent viscous damping ξeq for the displacement-based design (DBD) procedure could be estimated by Priestley et al. (2007) as the sum of the elastic viscous damping ξeq,v and the hysteretic viscous damping ξeq,h,v corrected by a reduction factor k in order to account for the random nature of seismic inputs.

Fig. 1
figure 1

Force–displacement behaviour of three different configurations of the experimental model: a bare post-tensioned frame (F); b dissipative frame (DF); c dissipative braced frame (BF)

$$\xi_{eq} = \xi_{{eq,{\text{v}}}} + k\xi_{{eq,h,{\text{v}}}}$$
(1)

The equivalent hysteretic viscous damping ξeq,h,v associated with the flag-shaped model is estimated as Eq. 2, where µ is the displacement ductility, r is the post-yield stiffness ratio and βF is the flag loop parameter which controls the global amount of energy dissipation provided to the system (Priestley and Grant 2005).

$$\xi_{{eq,h,{\text{v}}}} = \frac{{\beta_{F} \left( {\mu - 1} \right)}}{{\mu \pi \left[ {1 + r\left( {\mu - 1} \right)} \right]}}$$
(2)

Three configurations were designed starting from a target lateral displacement Δd (or drift) and assuming ξeq,v = 2%, k = 0.85 and flag loop parameter βF of 0, 0.4 and 0.8 as a function of the amount of equivalent hysteretic viscous damping, as reported in detail in (Di Cesare et al. 2019a; Ponzo et al. 2019):

  1. (i)

    Bare post-tensioned frame (F), representing the free rocking condition with post-tensioning only without energy dissipation (βF = 0, see Fig. 1a), designed for a target drift of about 3%;

  2. (ii)

    Dissipative frame (DF), representing the bare frame (F) with additional dissipative rocking at the beam-column joints and at the column-foundation connections (βF = 0.4, see Fig. 1b), designed for a target drift of about 2%;

  3. (iii)

    Braced frame (BF), representing the bare frame (F) with dissipative braces (βF = 0.8, see Fig. 1c), designed for a target drift of 1.25%.

The installation of the test frame specimen was completed in a short period of time of 2 days by two workers (Fig. 2a). An overview of the bare post-tensioned frame model is shown in Fig. 2b. During the third testing phase two V-inverted braces composed by glulam grade GL24h (CNR-DT 206 2018) timber rods in series with hysteretic dampers were added to each storey of the test model (Fig. 2c). Table 1 summarizes the total mass of the braced test frame.

Fig. 2
figure 2

General views of experimental model: a construction of the test frame; b post-tensioned timber bare frame; c braced frame, model with dissipative bracing systems

Table 1 Loads of the braced prototype frame

2.2 Testing apparatus

A plan and elevation view of the testing apparatus and the sensor location is shown in Fig. 3. The testing apparatus consisted of a single degree of freedom (in longitudinal direction) shaking table driven by an MTS dynamic actuator characterized by ±500 kN maximum load capacity of and ±250 mm stroke (Di Cesare et al. 2014b). The actuator has two cylindrical hinges and was fixed at the base of the shake table and pushed against a reaction wall. Three hydraulic pumps, each capable of a flow rate of 600 l/min, operated the actuator controlled by an inner load cell and temposonic linear displacement transducer. The shaking table consisted of a four-profile rail guides located under the columns, each composed by two carriages with a friction factor of less than 1%.

Fig. 3
figure 3

Testing apparatus and instrumentation considered for the post-tensioned timber frame specimen with dissipative bracing system

The seismic response of the frame was recorded by more than 50 acquisition channels. Different types of sensors were installed on the test frame, providing measurements of acceleration, displacement force and strain. A longitudinal, transversal and plan view of the instrumentation installed on the frame are shown in (Fig. 3). Fourteen horizontal and two vertical accelerometers were placed on different storey. The absolute horizontal displacements and rotations were measured directly by 7 displacement transducers connected from shake table to an external reference structure (Fig. 3). The tension loading of the post-tensioned bars in both directions was measured by 6 load cells, the gap opening due to the rocking motion was recorded by 3 potentiometers placed across 3 beam-column joints and 2 potentiometers at the base of 2 columns (see details in Fig. 4). Local force–displacement of the dissipative bracing systems were measured using a load cell and a potentiometer displacement transducer placed on all hysteretic dampers (see details in Fig. 6).

Fig. 4
figure 4

Construction details and instrumentation of: a beam to column joints, b column to shake table connections

2.3 Hysteretic dampers and construction details

Figure 4 shows the construction details of the beam to column joints and of the column to shake table connections. The structural elements were characterized by 320 × 200 mm cross sections for columns, 305 × 200 mm and 240 × 200 mm for primary and secondary beams respectively. The beam-column joints (Fig. 4a) were composed by a single 26.5 mm diameter steel bar crossing the beam, with fy = 1050 N/mm2 yield strength and 170 kN/mm2 Young’s modulus, post-tensioned at 100 kN and 50 kN for the longitudinal and transversal direction, respectively. In order to protect the column face, thirty-six ϕ 8 mm screws, 80 mm long screws were installed in the column face adjacent to the beam and 30 screws were installed in contact with the post-tensioning backing plate. Vertical loads were transferred through a ϕ 76.1 mm steel tube which extends 66 mm from the beam and sits inside to the column. Twenty-two ϕ 8 mm 80 mm long screws were used to reinforce where the beam and the post-tensioning backing plate meet the column. The post-tensioning forces in both directions were recorded by 2 load cells located in a monitored joint for each storey (Fig. 3). The column base connection (Fig. 4b) was fitted with a steel shoe which was epoxied into the base of the column and was left free to rock on a base plate using four ϕ 20 mm bars of 300 mm length. Shear transfer was achieved using a ϕ 76.1 mm steel tube which extended 15 mm from the steel shoe and slotted into a cavity in the base plate.

Based on the DIS-CAM concept (Dolce et al. 2006), the hysteretic dissipative devices considered for dissipative rocking at the beam-column joints (DF configuration) and at the column-foundation connections (DF and BF configurations) consisted of steel angles created by milling down a certain section of the angles. As shown in Fig. 4 the steel angles dampers were attached to the structural elements by M16 bolts fixed to backing plates. Moreover, a reinforcement with ten ϕ 80 mm long screws was introduced in the contact zone between the plate and the column. In order to facilitate the attachment of steel angles devices, holes were drilled and tapped in the steel shoe. Figure 5 shows the scheme adopted for quasi-static testing on steel angles devices of S275 steel grade and the force–displacement response behaviour for two different geometrical configurations relevant to beam-column joints (L 100 × 10 × 80) and to column-foundation connections (L 100 × 8.5 × 160), respectively. A test sequence was performed applying two cycles at increasing amplitudes up to the 100% of the design displacement (Di Cesare et al. 2013).

Fig. 5
figure 5

a Testing set-up for quasi-static testing of dissipating angle. Force–displacement behaviour of: b 2L 100 × 10 × 80 for beam-column joints and c L 100 × 8.5 × 160 for column-shake table connections

Each dissipative brace was composed by two 160 mm × 180 mm V-inverted timber rods and hysteretic dampers consisted of two C60 steel grade U-shaped flexural plates (UFP) dampers working in parallel. UFP devices were selected as dampers in order to provide steady restraint in horizontal direction, to accommodate rotations and vertical displacements, i.e. do not transmit bending moments and vertical loads (UNI EN 15129 2018). Figure 6 shows the construction details of bracing connection to UFP and beam. The UFPs were developed by Kelly et al. (1972) to provide energy dissipation between structural walls and adjacent floors, and then successfully used for other applications (Baird et al. 2014; Braga et al. 2019). The timber rods were designed to behave elastically for an axial force greater than the yielding force of the UFPs fixed to the top and bottom flanges through four M10 bolts. The bottom flange was held to the top of rods through height ϕ 8 mm 120 mm long screws and twelve ϕ 16 dowels. In order to acquire the shear force of the braces, the top flange was connected under the beam through a load cell with a pinned connection. In order to avoid possible out-of-plane displacements of braces, safety stoppers were installed, by using steel rigid elements with slotted holes which accommodate free relative displacement (without friction) between the UFPs and the rigid support of about 2 mm along out-of-plane direction and 20 mm along in-plan direction.

Fig. 6
figure 6

Details of dissipative bracing and UFP devices connections

Figure 7 shows the force–displacement behaviour of quasi-static characterization tests performed on couples of UFPs with different geometrical dimensions (named as UFP1, UFP2 and UFP3) installed to each storey of the braced frame (Di Cesare et al. 2019b).

Fig. 7
figure 7

a Testing set-up for quasi-static testing of U-shaped flexural plates dampers. Force–displacement behaviour of: b 2UFP1 for the first storey, c 2UFP2 for the second storey, d 2UFP3 for the third storey

The main characteristics of the steel yielding angles and UFPs hysteretic dampers, are reported in Table 2.

Table 2 Characteristics of the dissipative devices

3 Experimental results

3.1 Dynamic characteristics

The dynamic properties of the experimental model for the three considered configurations and have been identified by dynamic characterization tests. Hammer impact and pink noise excitation sources have been performed for the Welch’s Power Spectral Density (PSD) estimation (Welch 1961). Figure 8 show the experimental results in terms of frequencies corresponding to the first and second vibration mode in the main direction for the braced frame BF (blue line), dissipative frame DF (red line) and bare frame F (black line). As the mass remained almost the same, this result highlight, as expected, a greater stiffness of the BF model respect to the DF and F ones, more evident for the second mode.

Fig. 8
figure 8

Frequencies of first three modes of vibration for: bare frame (F), dissipative frame (DF), braced frame (BF)

Numerical non-linear dynamic analyses were performed in order to reproduce the experimental results (Di Cesare et al. 2017). The modelling of the test frame based on the lumped plasticity approach and using elastic timber elements connected with non-linear links was implemented using finite element software (SAP2000 and OpenSees). All detected frequencies and the relevant modes were used to calibrate the numerical models. More details about numerical modelling and comparison between numerical analysis and experimental results are reported in Ponzo et al. (2018), Di Cesare et al. (2019c).

3.2 Seismic test results

3.2.1 Ground motions and testing program

The experimental campaign was performed using a set of seven natural earthquake records, selected from the European strong motion database. These spectra-compatible records were defined according to the current Eurocode (UNI EN 1998-1 2013) considering a peak ground acceleration PGA of 0.44 g and medium soil class in high seismic zone (Italy). To ensure consistency with the scale of the experimental model, all input accelerations were scaled down in duration by a factor of 1/ √(3/2).

The shake table testing program for all experimental configurations (bare frame F, dissipative frame DF and braced frame BF) for the three selected seismic inputs considered in this paper is summarized in Table 3. In Fig. 9 the spectra of ground motions and their average spectrum are compared with the elastic DBE spectrum. In case of bare frame (F) the PGA level was increased up to 75% because an imposed interlock of 3.5% of maximum inter-storey drift was reached, except for the weaker earthquake (ID code 1228).

Table 3 Testing selection and experimental model configurations considered in this paper
Fig. 9
figure 9

Seismic inputs selected for experimental results

3.2.2 Global seismic response

The global seismic response of shaking table tests performed on all model configurations for all selected seismic inputs are shown in Fig. 10 in terms of distribution along the building height of the maximum and mean values of key parameters: maximum inter-storey drift (MID), maximum storey displacement (MD) and acceleration (MA) and maximum columns shear force (MCF). As can be observed, the effect of the dissipating braces is clearly evidenced from the reduction of MID and MD values. Comparing the MID of the three configurations no significant variations of the mean values were observed up to 25% of PGA. It is worth noting that the dissipative devices become effective in reducing the drift respect to the bare frame F when the earthquake intensity exceeded a threshold value of 25% of PGA as a function of the yield strength of the dampers. In particular, for the BF model at 75% of PGA the values of MID and MD reduced of about 20% than DF model and of about 45% than F model, while MA values were similar for all configurations due to the additional damping of the dissipative bracing system. It is interesting to note that for the BF configuration the values of the MIDs at all stories were comparable (this means an optimal activation of the dampers) and the mean value of MID was about 1.5% at 100% of PGA, coherently with experimental results of Pres-Lam structures with rocking walls at the DBE level (Newcombe et al. 2010; Pei et al. 2019). This result further proved the reliability and robustness of the design procedure (design drift 1.25%) meeting the criteria for regularity in elevation required by code for buildings categorised as regular in elevation (Ponzo et al. 2019).

Fig. 10
figure 10

Distribution along the building height of the experimental maximum values of key parameters for all tests

The MCF profiles highlighted that the introduction of dissipative bracing systems was effective in reducing the columns shear respect to DF and F configurations. The bare frame F and the dissipative rocking frame DF exhibited the highest values of MID and MA when subjected to the earthquake 535, characterized by high spectral values in comparison with those of the elastic design spectrum in the range of vibration periods of interest for the examined cases (T1 > 0.5 s). The earthquake 196 provided the highest response for the braced frame BF, this behaviour can be explained comparing the spectral acceleration corresponding to the fundamental vibration periods of the structure with damped braces (see Fig. 9).

The results of BF model under the seismic action having a larger probability of occurrence than the design seismic action (50% of PGA), showed that the “damage limitation requirement” was satisfied (UNI EN 1998-1 2013), limiting the average values of maximum inter-storey drift to MID < 0.75% (see mean BF of Fig. 10), in accordance with buildings having ductile non-structural elements. Considering the complete set of seismic inputs, including the earthquakes not reported in this study, the test specimen was subjected to over 30 tests for each model configuration increasing PGA levels (from 10% to 100%). During the complete set of ground motions at various intensities the post-tensioned bars were not re-tensioned, highlighting the capability of the building to withstand multiple consecutive strong earthquakes.

The maximum global base shear and corresponding mean values are shown in Fig. 11a for all configurations of selected seismic inputs at increasing PGA levels. The base shear is obtained by subtracting from the actuator force the contribution of the shake table due to its inertial mass (5kN) and frictional forces (friction coefficient less than 1%). As expected, the global base shear reached by the BF, evaluated as the sum of shear columns and braces, was greater than ones relevant to DF and F configurations.

Fig. 11
figure 11

a Base shear and b Post-tensioning force variation profiles at increasing PGA levels for selected seismic inputs

The maximum and mean variation of post-tensioning force ΔPT are shown in Fig. 11b for all configurations at increasing PGA levels. The maximum percentage of variation of PT force, calculated as ΔPT = (PTmax − PTinitial)/100, was highest for the case of bare frame F model, with a mean value of ΔPT of about 50% at PGA of 75%. In case of BF model the mean value of ΔPT was almost 25% at PGA of 100%. Moreover, the post-tensioning loss due to seismic action, defined as the variation between the initial and the final value of the post-tensioning force recorded within the complete set of ground motion for each testing configuration, is negligible for the cases of bare post-tensioned frame (F model) and of braced frame (BF model). It is about 2% for the dissipative frame (DF model) configuration due to the strengthening effect of dissipative angles of the post-tensioned beam-column joints.

Figure 12 reports the time history of first storey drifts for all testing configurations, considering the seismic inputs at 25% and 75% of PGA level. The comparison confirmed a drift increasing of about 2 times of the maximum peak values for F and DF models respect the BF model. The recorded time histories highlighted that all configurations of the building frame were able to recentre with negligible residual drift even for large events.

Fig. 12
figure 12

Inter-storey drift time history for selected seismic inputs at 25% and 75% of PGA levels for all test configurations

3.2.3 Global hysteresis

The global building hysteresis in terms of base shear versus inter-storey drift for all testing configurations are shown in Figs. 13, 14 and 15 considering all selected seismic inputs at 25%, 75% and 100% of PGA levels, respectively. The hysteresis curves at low-level ground motions (PGA level of 25%, see Fig. 13) show that the frame responses of all configurations are nearly elastic.

Fig. 13
figure 13

Base shear versus inter-storey drift for selected seismic inputs of all testing configurations at 25% of PGA

Fig. 14
figure 14

Base shear versus inter-storey drift for selected seismic inputs of all testing configurations at 75% of PGA

Fig. 15
figure 15

Base shear versus inter-storey drift for selected seismic inputs of all testing configurations at 100% of PGA

In case of strong earthquakes (Figs. 14 and 15) the global flag shape hysteretic loop was more evident. As can be observed, the braced frame BF configuration was able to dissipate higher amount of energy through hysteretic damping for the strongest earthquake inputs (EQ 196 and EQ 535). In case of tests with earthquake EQ 535, from Figs. 14 and 15 is evident that the seismic response of the structure was drastically reduced in terms of drift amplitude with a slight increase of base shear when the dissipative bracing systems were used.

The braced model configuration BF permitted the highest value of PGA to be reached, without visible structural damage. The overall hysteretic energy dissipation is a reflection of many contributors, mainly including the yielding of hysteretic dampers and nonlinear geometric behaviour of rocking mechanisms of beam-column joints and of column-foundation connections.

In order to evaluate the effectiveness of the additional energy dissipation systems, the equivalent viscous damping of the three testing frame configurations was estimated. Figure 16a shows the acceleration-drift design spectra compared with the experimental values of maximum total drift versus the corresponding acceleration recorded during the selected tests.

Fig. 16
figure 16

a Design spectra and experimental peak values of all model configurations; b hysteretic experimental damping estimation at increasing PGA values for DF and BF model configurations

Figure 16b shows the experimental damping values estimated from the global hysteretic behaviour of the DF and BF configurations for increasing ground motion intensities using the hysteretic area-based approach proposed by Jacobsen (1960), Priestley et al. (2007). Based on the concept of dissipated (EDiss) and stored (Esto) energy, the experimental damping ξexp was estimated as Eq. 3, where Ahyst represents the area of dissipated energy, F0 and u0 are the maximum force and displacement for the given hysteretic loop.

$$\xi_{exp} = \frac{1}{2\pi }\frac{{A_{hyst} }}{{F_{0} u_{0} }}$$
(3)

As can be observed in Fig. 16b, the mean value of the hysteretic experimental damping grows for increasing PGA levels. At 10% of PGA the hysteretic dampers were not yet activated and the experimental equivalent damping was almost the same for both configurations (ξexp ≅ 2.5%). At higher PGA levels the hysteretic experimental damping of BF was significantly higher than DF configuration. It was stable around 14% in BF configuration and around 6% in DF configuration. The trend of the experimental results of Fig. 16 was in line with the equivalent damping obtained by the design (6% of DF model; 12% of BF model) confirming the increase of strength and stiffness passing from bare frame F to dissipative frame DF and braced frame BF configurations.

3.2.4 Local hysteresis of dissipative braces

The local hysteresis of the UFP dampers at each storey of the braced frame BF are displayed in Figs. 17, 18 and 19 in terms of force–displacement behaviour for the selected ground motions at 25%, 75% and 100% of PGA levels, respectively.

Fig. 17
figure 17

Force–displacement of UFPs of each storey of the BF model for selected seismic inputs at 25% of PGA

Fig. 18
figure 18

Force–displacement of UFPs of each storey of the BF model for selected seismic inputs at 75% of PGA

Fig. 19
figure 19

Force–displacement of UFPs of each storey of the BF model for selected seismic inputs at 100% of PGA

As mentioned above, figures show that the UFP dampers were not fully activated at lower intensities (25% of PGA, Fig. 17) for all seismic inputs and were mobilized exhibiting an excellent dissipative capacity at higher PGA levels (75% of PGA, Fig. 18, and 100% of PGA, Fig. 19).

The UFPs at all stories (UFP1, UFP2 and UFP3) showed a stable hysteretic behaviour without degradation in strength and stiffness with similar maximum displacements. This response confirmed the uniform distribution of the maximum inter-storey drift (MID) along the building height (see Fig. 10), thus minimizing the possibility of concentration of excessive inelastic deformation and damage in a single storey or in localized regions. It is pointed out that the characteristics of hysteretic behaviour of UFPs obtained from the dynamic tests are consistent with the results obtained by the quasi-static cyclic tests performed on the mock-up devices (see Fig. 7).

4 Conclusions

In this paper, experimental dynamic testing on a 2/3 scaled, 3 storey post-tensioned timber frame building equipped with dissipative bracing systems has been investigated. The experimental test performed at the structural laboratory of the University of Basilicata represents a large-scale shake table testing performed on a glulam post-tensioned timber frame with hysteretic dissipative braces as additional earthquake resistant system. The testing of braced frame (BF) was part of an extensive shake table testing campaign, also including the bare post-tensioned frame (F) and dissipative rocking frame (DF) with steel angles placed at the beam-column and column foundation joints. All experimental results proved the robustness of the design procedure and pointed out the fundamental role of the dissipative bracing system in controlling the seismic vibrations improving the performance of the post-tensioned timber frame building. The following observations and conclusions can be drawn based on the comparison between the experimental test results of all model configurations.

  1. 1

    The bracing system composed by V-inverted timber braces including external replaceable steel U-shaped flexural plates (UFP) dampers allowed of developing a resilient and more flexible architectural system for Pres-Lam buildings without changing the gravitational load distribution on beams and columns and reducing the influence on the post-tensioned beam-column joints.

  2. 2

    The fundamental period of the braced frame BF is compliant with the building height, increasing stiffness and reducing deformation respect to F model and DF model. The dissipative bracing system significantly increased the equivalent viscous damping of the system to values of about 12% for earthquakes levels equal or higher than 50% of PGA, in good agreement with the design procedure.

  3. 3

    The introduction of the dissipative bracing systems resulted in significant benefits on the overall seismic behaviour, reducing the maximum inter-storey drift and the columns shear force MCF, with a similar maximum storey acceleration MA and a slight increase of global base shear. In particular, the mean value of the maximum inter-storey drifts of the braced frame BF is < 0.75% at 50% of PGA level, compatible with ductile non-structural elements, and about 1.5% at 100% of PGA.

  4. 4

    UFPs remained in elastic range at input levels lower than 25% of PGA and exhibited an excellent dissipative capacity when PGA level increased up to 75%. Local response of UFP dampers of the bracing system showed a stable hysteretic behaviour for all seismic inputs under a large number of deformation cycles up to ductility values higher than 4.

  5. 5

    The global response of the braced model showed a flag-shaped hysteretic behaviour with a complete re-centering capability. The combination of Pres-Lam timber frame and dissipative bracing system has permitted to achieve a resilient seismic performance without observing structural damages or post-tensioning losses under repeated earthquakes.