Skip to main content
Log in

Comparison of space cooling/heating load under non-uniform indoor environment with convective heat gain/loss from envelope

  • Research Article
  • Published:
Building Simulation Aims and scope Submit manuscript

Abstract

The indoor parameters are generally non-uniform distributed. Consequently, it is important to study the space cooling/heating load oriented to local requirements. Though the influence of indoor set point, heat sources, and ambient temperature of convective thermal boundary on cooling/heating load has been investigated in the uniform environment in previous research, the influence of these factors, particularly the convective heat gain/loss through a building envelope, on cooling/heating load of non-uniform environment has not yet been investigated. Therefore, based on the explicit expression of indoor temperature under the convective boundary condition, the expression of space cooling/heating load with convective heat transfer from the building envelope is derived and compared through case studies. The results can be summarized as follows. (1) The convective heat transferred through the building envelope is significantly related to the airflow patterns: the heating load in the case with ceiling supply air, where the supply air has a smaller contribution to the local zone, is 24% higher than that in the case with bottom supply air. (2) The degree of influence from each thermal boundary to the local zone of space cooling cases is close to that of a uniform environment, while the influence of each factor, particularly that of supply air, is non-uniformly distributed in space heating. (3) It is possible to enhance the influence of supply air and heat source with a reasonable airflow pattern to reduce the space heating load. In general, the findings of this study can be used to guide the energy savings of rooms with non-uniform environments for space cooling/heating.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Cao G, Awbi H, Yao R, Fan Y, Sirén K, Kosonen R, Zhang J (2014). A review of the performance of different ventilation and airflow distribution systems in buildings. Building and Environment, 73: 171–186.

    Article  Google Scholar 

  • Chen Q, Xu W (1998). A zero-equation turbulence model for indoor airflow simulation. Energy and Buildings, 28: 137–144.

    Article  Google Scholar 

  • Cheng Y, Yang B, Lin Z, Yang J, Jia J, Du Z (2018). Cooling load calculation methods in spaces with stratified air: A brief review and numerical investigation. Energy and Buildings, 165: 47–55.

    Article  Google Scholar 

  • Haghshenaskashani S, Sajadi B, Cehlin M (2018). Multi-objective optimization of impinging jet ventilation systems: Taguchi-based CFD method. Building Simulation, 11: 1207–1214.

    Article  Google Scholar 

  • Huang H, Kato S, Hu R (2012). Optimum design for indoor humidity by coupling Genetic Algorithm with transient simulation based on Contribution Ratio of Indoor Humidity and Climate analysis. Energy and Buildings, 47: 208–216.

    Article  Google Scholar 

  • Kabanshi A, Ameen A, Hayati A, Yang B (2018). Cooling energy simulation and analysis of an intermittent ventilation strategy under different climates. Energy, 156: 84–94.

    Article  Google Scholar 

  • Kong X, Xi C, Li H, Lin Z (2019). A comparative experimental study on the performance of mixing ventilation and stratum ventilation for space heating. Building and Environment, 157: 34–46.

    Article  Google Scholar 

  • Lau J, Niu JL (2003). Measurement and CFD simulation of the temperature stratification in an atrium using a floor level air supply method. Indoor and Built Environment, 12: 265–280.

    Article  Google Scholar 

  • Li X, Zhao B (2004). Accessibility: A new concept to evaluate ventilation performance in a finite period of time. Indoor and Built Environment, 13: 287–293.

    Article  Google Scholar 

  • Liang C, Shao X, Li X (2017). Energy saving potential of heat removal using natural cooling water in the top zone of buildings with large interior spaces. Building and Environment, 124: 323–335.

    Article  Google Scholar 

  • Liang C, Shao X, Melikov AK, Li X (2018). Cooling load for the design of air terminals in a general non-uniform indoor environment oriented to local requirements. Energy and Buildings, 174: 603–618.

    Article  Google Scholar 

  • Luo Y, Zhang L, Bozlar M, Liu Z, Guo H, Meggers F (2019). Active building envelope systems toward renewable and sustainable energy. Renewable and Sustainable Energy Reviews, 104: 470–491.

    Article  Google Scholar 

  • Melikov AK, Cermak R, Majer M (2002). Personalized ventilation: evaluation of different air terminal devices. Energy and Buildings, 34: 829–836.

    Article  Google Scholar 

  • Pérez-Lombard L, Ortiz J, Pout C (2008). A review on buildings energy consumption information. Energy and Buildings, 40: 394–398.

    Article  Google Scholar 

  • Shao X, Li X (2015). Evaluating the potential of airflow patterns to maintain a non-uniform indoor environment. Renewable Energy, 73: 99–108.

    Article  Google Scholar 

  • Shao X, Ma X, Li X, Liang C (2017). Fast prediction of non-uniform temperature distribution: A concise expression and reliability analysis. Energy and Buildings, 141: 295–307.

    Article  Google Scholar 

  • Singh S, Abbassi H (2018). 1D/3D transient HVAC thermal modeling of an off-highway machinery cabin using CFD-ANN hybrid method. Applied Thermal Engineering, 135: 406–417.

    Article  Google Scholar 

  • Thordal MS, Bennetsen JC, Koss HHH (2019). Review for practical application of CFD for the determination of wind load on high-rise buildings. Journal of Wind Engineering and Industrial Aerodynamics, 186: 155–168.

    Article  Google Scholar 

  • Tian W, Han X, Zuo W, Sohn MD (2018). Building energy simulation coupled with CFD for indoor environment: A critical review and recent applications. Energy and Buildings, 165: 184–199.

    Article  Google Scholar 

  • Tian L, Lin Z, Wang Q, Liu J (2009). Numerical investigation of indoor aerosol particle dispersion under stratum ventilation and under displacement ventilation. Indoor and Built Environment, 18: 360–375.

    Article  Google Scholar 

  • Vakiloroaya V, Samali B, Fakhar A, Pishghadam K (2014). A review of different strategies for HVAC energy saving. Energy Conversion and Management, 77: 738–754.

    Article  Google Scholar 

  • Xie D, Wang Y, Wang H, Mo S, Liao M (2016). Numerical analysis of temperature non-uniformity and cooling capacity for capillary ceiling radiant cooling panel. Renewable Energy, 87: 1154–1161.

    Article  Google Scholar 

  • Yan S, Li X (2020). Analytical expression of indoor temperature distribution in generally ventilated room with arbitrary boundary conditions. Energy and Buildings, 208: 109640.

    Article  Google Scholar 

  • Yang J, Li X, Zhao B (2004). Prediction of transient contaminant dispersion and ventilation performance using the concept of accessibility. Energy and Buildings, 36: 293–299.

    Article  Google Scholar 

  • Ye X, Kang Y, Yang X, Zhong K (2018). Temperature distribution and energy consumption in impinging jet and mixing ventilation heating rooms with intermittent cold outside air invasion. Energy and Buildings, 158: 1510–1522.

    Article  Google Scholar 

  • Zhang S, Cheng Y, Oladokun MO, Huan C, Lin Z (2019). Heat removal efficiency of stratum ventilation for air-side modulation. Applied Energy, 238: 1237–1249.

    Article  Google Scholar 

  • Zuo W, Chen Q (2010). Simulations of air distributions in buildings by FFD on GPU. HVAC&R Research, 16: 785–798.

    Article  Google Scholar 

  • Zhao B, Li X, Chen X, Huang D (2004). Determining ventilation strategy to defend indoor environment against contamination by integrated accessibility of contaminant source (IACS). Building and Environment, 39: 1035–1042.

    Article  Google Scholar 

Download references

Acknowledgements

This study was supported by the National Natural Science Foundation of China (No. 51638010 and No. 51578306).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xianting Li.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yan, S., Li, X. Comparison of space cooling/heating load under non-uniform indoor environment with convective heat gain/loss from envelope. Build. Simul. 14, 565–578 (2021). https://doi.org/10.1007/s12273-020-0708-0

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-020-0708-0

Keywords

Navigation