A numerical study on the effect of column layout on air distribution and performance of column attachment ventilation

  • Research Article
  • Published:
Building Simulation Aims and scope Submit manuscript

Abstract

Based on the structural characteristics of existing buildings and the disadvantages of current mixed ventilation mode in the application to large space buildings, an original column attachment ventilation (CAV) has been proposed. In this study, the experiment utilized a room space with four columns uniformly distributed in the space to visualize the movement of attached airflow along the cylinder surface and the floor, the numerical technique was employed to study the effects of the column layout (i.e., uniform, centralized, dispersed, and crossed distribution) on the air distribution of CAV mode in a standard four-column full scale model of a shopping mall. Seven indices, including airflow pattern, air diffusion performance index (ADPI), air temperature distribution, heat removal effectiveness, draught rate (DR), predicted mean vote (PMV), and carbon dioxide (CO2) concentration, were used to assess the ventilation performance. In the CAV mode with a uniform column layout scheme, the experimental results indicated that the air supply flows downward along the wall surface, forming a secondary attachment with the ground and spreading along the floor in a fan radiation flow mode. Further, an “air lake”—like speed and temperature distribution similar to displacement ventilation (DV) was formed in the occupied zone. In all simulation cases, it was found that the average air velocity was less than 0.25 m/s in occupied zone, the effectiveness for heat removal was more significant than 1.0, DR value was less than 20%, the PMV level can also satisfy most people. The average CO2 concentration was around 470 ppm in the occupied breathing zone. These results indicated that the CAV mode could be an efficient air distribution method. They demonstrated the technical feasibility of applying the CAV in the space under different column layout schemes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Alotaibi S, Chakroun W, Habchi C, Ghali K, Ghaddar N (2019). Influence of mixed and displacement air distribution systems’ design on concentrations of micro-particles emitted from floor or generated by breathing. Journal of Building Engineering, 26: 100855.

    Google Scholar 

  • ASHRAE (2011). ANSI/ASHRAE Standard 70 (RA 2011): Method of Testing the Performance of Air Outlets and Air Inlets. Atlanta: American Society of Heating, Refrigerating, and Air Conditioning Engineers.

    Google Scholar 

  • ASHRAE (2015). ASHRAE Handbook: HVAC Applications. Atlanta: American Society of Heating, Refrigerating, and Air Conditioning Engineers.

    Google Scholar 

  • ASHRAE (2016) ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings. Atlanta: American Society of Heating, Refrigerating, and Air Conditioning Engineers.

    Google Scholar 

  • ASHRAE (2017). ANSI/ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy. Atlanta: American Society of Heating, Refrigerating, and Air Conditioning Engineers.

    Google Scholar 

  • Bofah P, Choudhury AK (1985). Modelling and design of nonlinear feedback control law for a large space hoop-column antenna. In: Proceedings of the 24th IEEE Conference on Decision and Control, Fort Lauderdale, FL, USA.

  • Cao G, Nilssen AM, Cheng Z, Stenstad L-I, Radtke A, Skogås JG (2019). Laminar airflow and mixing ventilation: Which is better for operating room airflow distribution near an orthopedic surgical patient? American Journal of Infection Control, 47: 737–743.

    Google Scholar 

  • Causone F, Baldin F, Olesen BW, Corgnati SP (2010). Floor heating and cooling combined with displacement ventilation: Possibilities and limitations. Energy and Buildings, 42: 2338–2352.

    Google Scholar 

  • Chen HJ, Moshfegh B, Cehlin M (2013). Investigation on the flow and thermal behavior of impinging jet ventilation systems in an office with different heat loads. Building and Environment, 59: 127–144.

    Google Scholar 

  • Chen C, Zhao B, Lai D, Liu W (2018). A simple method for differentiating direct and indirect exposure to exhaled contaminants in mechanically ventilated rooms. Building Simulation, 11: 1039–1051.

    Google Scholar 

  • Cheng Y, Fong ML, Yao T, Lin Z, Fong KF (2014). Uniformity of stratum-ventilated thermal environment and thermal sensation. Indoor Air, 24: 521–532.

    Google Scholar 

  • Du Bois D, Du Bois EF (1916). Clinical calorimetry: Tenth paper a formula to estimate the approximate surface area if height and weight be known. JAMA Internal Medicine, 17: 863–871.

    Google Scholar 

  • Du J, Li N (2014) Study on indoor air quality of ceiling radiant cooling panel system integrated with displacement ventilation. In: Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning, Xi’an, China.

  • Etheridge DW, Sandberg M (1996). Building Ventilation: Theory and Measurement. Chichester, UK: John Wiley & Sons.

    Google Scholar 

  • GB/T 18883-2002 (2002). Indoor Air Quality Standard. Beijing: China Standards Press. (in Chinese)

    Google Scholar 

  • Gibson MM, Launder BE (1978). Ground effects on pressure fluctuations in the atmospheric boundary layer. Journal of Fluid Mechanics, 86: 491–511.

    MATH  Google Scholar 

  • Han O, Li A, Kosonen R (2019). Hood performance and capture efficiency of kitchens: A review. Building and Environment, 161: 106221.

    Google Scholar 

  • Heiselberg P (2014). Ventilation of large spaces in buildings: Analysis and prediction techniques. IEA Annex 26 Report.

  • ISO (2005). BS EN ISO 7730-2005: Ergonomics of the Thermal Environment—Analytical Determination and Interpretation of Thermal Comfort Using Calculation of the PMV and PPD Indices and Local Thermal Comfort Criteria. Geneva: International Organization for Standardization.

    Google Scholar 

  • Karimipanah T, Awbi HB (2002). Theoretical and experimental investigation of impinging jet ventilation and comparison with wall displacement ventilation. Building and Environment, 37: 1329–1342.

    Google Scholar 

  • Kodur V, MacKinnon D (1998). Simplified design of concrete-filled hollow structural steel columns for fire endurance. Journal of Constructional Steel Research, 46: 298.

    Google Scholar 

  • Li A (2019). Extended Coanda Effect and attachment ventilation. Indoor and Built Environment, 28: 437–442.

    Google Scholar 

  • Liang C, Shao X, Li X (2017). Energy saving potential of heat removal using natural cooling water in the top zone of buildings with large interior spaces. Building and Environment, 124: 323–335.

    Google Scholar 

  • Lin Z, Chow TT, Fong KF, Wang Q, Li Y (2005). Comparison of performances of displacement and mixing ventilations. Part I: thermal comfort. International Journal of Refrigeration, 28: 276–287.

    Google Scholar 

  • Lin Z, Chow TT, Tsang CF (2006). Validation of a CFD model for research into stratum ventilation. International Journal of Ventilation, 5: 345–363.

    Google Scholar 

  • Liu B, Min K, Song J (2015). Effect of thermal plume on personal thermal comfort in displacement ventilation at one side of the room. Procedia Engineering, 121: 1058–1066.

    Google Scholar 

  • Liu Z (2016). Study on air distribution characteristics and design procedures of square column-attached air curtain ventilation. Master Thesis, Xi’an University of Architecture and Technology, China. (in Chinese)

    Google Scholar 

  • Liu J, Dalgo DA, Zhu S, Li H, Zhang L, Srebric J (2019). Performance analysis of a ductless personalized ventilation combined with radiant floor cooling system and displacement ventilation. Building Simulation, 12: 905–919.

    Google Scholar 

  • Mujan I, Andelković AS, Munćan V, Kljajić M, Ružić D (2019). Influence of indoor environmental quality on human health and productivity — A review. Journal of Cleaner Production, 217: 646–657.

    Google Scholar 

  • Pang P (2013). Research on staggered arrangement wall large space residential system. Advanced Materials Research, 838–841: 2850–2853.

    Google Scholar 

  • Pang P, Sun L (2013). Research on large space residential system. Advanced Materials Research, 838–841: 2846–2849.

    Google Scholar 

  • Satish U, Mendell MJ, Shekhar K, Hotchi T, Sullivan D, et al. (2012). Is CO2 an indoor pollutant? Direct effects of low-to-moderate CO2 Concentrations on human decision-making performance. Environmental Health Perspectives, 120: 1671–1677.

    Google Scholar 

  • Schell M, Int-Hout D (2001). Demand control ventilation using CO2. ASHRAE Journal, 43(2): 18–29.

    Google Scholar 

  • Schmeling D, Bosbach J (2017). On the influence of sensible heat release on displacement ventilation in a train compartment. Building and Environment, 125: 248–260.

    Google Scholar 

  • Sommer K, Kabele K, Kotrbaty M, Petras D, Hojer O (2011). Energy efficient heating and ventilation of large halls. REHVA Guidebook No. 15. Brussels: Federation of European Heating, Ventilation and Air Conditioning Associations.

    Google Scholar 

  • Tang X, Zhong C, Wu L (2014). The research of column base culture in Chinese traditional architectures. Advanced Materials Research, 1065–1069: 2661–2668.

    Google Scholar 

  • Tian L, Lin Z, Wang Q (2010). Comparison of gaseous contaminant diffusion under stratum ventilation and under displacement ventilation. Building and Environment, 45: 2035–2046.

    Google Scholar 

  • Tikka TK, Mirza SA (2009). Equivalent uniform moment diagram factor for structural concrete columns. Canadian Journal of Civil Engineering, 36: 219–240.

    Google Scholar 

  • Versteeg H, Malalasekera W (2007). An Introduction to Computational Fluid Dynamics: The finite Volume Method. Harlow, UK: Pearson Education.

    Google Scholar 

  • Wang Y, Wong KKL, Du H, Qing J, Tu J (2014). Design configuration for a higher efficiency air conditioning system in large space building. Energy and Buildings, 72: 167–176.

    Google Scholar 

  • Wang B, Zhao D, Hui C, Han W, Wang Y (2016). Experimental investigation and analysis on the mechanical behavior of upright column with decorative wings. Steel Construction, 31(10): 34–37. (in Chinese).

    Google Scholar 

  • Wu G, Xue K, Wang J, Li D (2011). Analysis of indoor thermal environment and air-conditioning mode of ventilation in large space building. In: Proceedings of Computer Science for Environmental Engineering and Eco Informatics (CSEEE 2011), Harbin, China.

  • Ye X, Kang Y, Yang F, Zhong K (2019). Comparison study of contaminant distribution and indoor air quality in large-height spaces between impinging jet and mixing ventilation systems in heating mode. Building and Environment, 160: 106159.

    Google Scholar 

  • Yin H, Li A (2016). Study of attached air curtain ventilation within a full-scale enclosure: comparison of four turbulence models. Indoor and Built Environment, 25: 962–975.

    Google Scholar 

  • Yin H, Li A, Liu Z, Sun Y, Chen T (2016). Experimental study on airflow characteristics of a square column attached ventilation mode. Building and Environment, 109: 112–120.

    Google Scholar 

  • Yin H, Wu R, Chen T, Sun Y, Li A (2017). Study on ventilation effectiveness of circular column attached displacement ventilation mode. Procedia Engineering, 205: 3511–3518.

    Google Scholar 

  • Yu J, Cao P, Wu K, Min M (2012). Influence analysis of layout of braces on structural dynamic properties of large space multi-storey buildings. Applied Mechanics and Materials, 226–228: 901–904.

    Google Scholar 

  • Yuan X, Chen Q, Glicksman LR (1999). Models for prediction of temperature difference and ventilation effectiveness with displacement ventilation. ASHRAE Transactions, 105(1): 353–367.

    Google Scholar 

  • Zhang L, Liu X, Zhao K, Jiang Y (2015). Entransy analysis and application of a novel indoor cooling system in a large space building. International Journal of Heat and Mass Transfer, 85: 228–238.

    Google Scholar 

  • Zhang S, Cheng Y, Huan C, Lin Z (2018a). Heat removal efficiency based multi-node model for both stratum ventilation and displacement ventilation. Building and Environment, 143: 24–35.

    Google Scholar 

  • Zhang S, Cheng Y, Huan C, Lin Z (2018b). Modeling non-uniform thermal environment of stratum ventilation with supply and exit air conditions. Building and Environment, 144: 542–554.

    Google Scholar 

  • Zhao K, Liu X, Jiang Y (2016). Application of radiant floor cooling in large space buildings—A review. Renewable and Sustainable Energy Reviews, 55: 1083–1096.

    Google Scholar 

  • Zhu Y (2016). Built Environment. Beijing: China Architecture & Building Press. (in Chinese)

    Google Scholar 

Download references

Acknowledgements

This study was jointly funded by the National Natural Science Foundation of China (No. 51408477), the Innovative Talent Promotion Plan of Shaanxi Province (No. 2018KJXX-087), and the Youth Talent Support Project of Xi’an Association for Science and Technology.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Haiguo Yin.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yin, H., Li, L., Wu, R. et al. A numerical study on the effect of column layout on air distribution and performance of column attachment ventilation. Build. Simul. 14, 1095–1108 (2021). https://doi.org/10.1007/s12273-020-0699-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-020-0699-x

Keywords

Navigation