Abstract
This study focused on the development of an effective method to determine the spatial distribution and content of acetaminophen in intact tablets. We scanned tablets by confocal micro-Raman spectroscopy using live video imaging with a microscope to identify the three ingredients of the tablet formulation, acetaminophen, starch, and hydrated magnesium silicate. Tablets with five different acetaminophen concentrations (5.0–37.5%) were scanned at a spectral resolution of 1000 × 1000 μm. Imaging of tablet surface scans generated characteristic Raman spectra, which were used to rapidly and accurately characterize acetaminophen tablets. The spatial distribution of the drug in the tablet was used to assess the homogeneity of the drug formulation. The tablet composition was determined using single-peak spectra of the raw materials of the tablet formulation as references. Characteristic Raman scanning patterns of acetaminophen tablets were used to determine the composition of different formulations. Importantly, we found that acetaminophen was homogeneously distributed in tablets with low drug concentration. Thus, we developed a confocal micro-Raman spectroscopy method to evaluate the spatial distribution and content of each ingredient in intact acetaminophen tablets. Our new method can be used for the validation of the drug preparation process, the verification of the drug dose, and the authentication of the drug.
Similar content being viewed by others
Change history
10 August 2021
A Correction to this paper has been published: https://doi.org/10.1007/s11051-021-05265-7
Abbreviations
- DCLS:
-
Direct classical least squares
- SNR:
-
Signal-to-noise ratios
References
Alexandrino GL, Poppi RJ (2013) NIR imaging spectroscopy for quantification of constituents in polymers thin films loaded with paracetamol. Anal Chim Acta 765:37–44
Amigo JM (2010) Practical issues of hyperspectral imaging analysis of solid dosage forms. Anal Bioanal Chem 398:93–109
Breitenbach J, Schrof W, Neumann J (1999) Confocal Raman spectroscopy:analytical approach to solid dispersions and mapping of drugs. Pharm Res 16:1109–1113
Breitkreitz MC, Sabi GP, Polla G et al (2013) Characterization of semi-solid self-emulsifying drug delivery systems(sedds)of atorvastatin calcium by Raman image spectroscopy and chemometrics. J Pharm Biomed Anal 73:3–12
Clarke F (2004) Extracting process-related information from pharmaceutical dosage forms using near-infrared microscopy. Vib Spectrosc 34:2140–2146
Docoslis A, Huszarik KL, Papageorgiou GZ et al (2007) Characterization of distribution,polymorphism,and stability of nimodipine in its solid dispersions in polyethylene glycol by micro-Raman spectroscopy and powder x-ray diffraction. AAPS J 9:361–370
Eksi-kocak H, Tamer SI, Yilmaz S et al (2018) Quantification and spatial distribution of salicylic acid in film tablets using FT-Raman mapping with multivariate curve resolution. Asian J Pharmaceut Sci 13:155–162
Fruyama N, Hasegawa S, Hamaura T et al (2008) Evaluation of solid dispersions on a molecular level by the Raman mapping technique. Int J Pharm 361:12–18
Heinz A, Savolainen M, Rades T et al (2007) Quantifying ternary mixtures of different solid state forms of indomethacin by Raman and near-infrared spectroscopy. Eur J Pharm Sci 32:182–192
Li B, Calvet A, Boucau YC et al (2015) Low-content quantification using spectroscopy:a facile chemometric approach to sub 0.1% limits of detection. Anal Chem 87:3419–3428
Lin WQ, Jiang HF et al (2006) Characterization of chloramphenicol palmitate drug polymorphs by Raman mapping with multivariate image segmentation using a spatial directed agglomeration clustering method. Anal Chem 78:6003–6011
Maltas DC, Kwok K, Wang P et al (2013) Rapid classification of pharmaceutical ingredient with Raman spectroscopy using compressive detection strategy with PLS-DA multivariate filters. J Pharm Biomed Anal 80:60–68
Sacre PY, Bleye CD, Chayes PF et al (2014) Data processing of vibrational chemical imaging for pharmaceutical applications. J Pharm Biomed Anal 101:123–140
Šašić S et al (2004) A comparison of Raman chemical images produced by univariate and multivariate data processing-a simulation with an example from pharmaceutical practice. Analyst 129:1001–1007
Scoutaris N, Vithani K, Slipper I et al (2014) SEM-EDX along with confocal Raman microscopy as complemetary tools for the characterization of pharmaceutical tablets. Int J Pharm 471:88–98
Spencer JA, Kauffman JF, Reepmeyer JC et al (2009) Screening of heparin API by near infrared reflectance and Raman spectroscopy. J Pharm Sci 98:3540–3547
Stephenson GA, Forbes RA, Reutzel-Edens SM (2001) Characterization of solid state:quantitative issues. Drug Deliv Rev 48:67–90
Vajna B, Farkas I, Farkas A et al (2011) Characterization of drug-cyclodextrin formulations using Raman mapping and multivariate curve resolution. J Pharm Biomed Anal 56:38–44
Vajna B, Farkas A, Pataki H et al (2012) Testing the performace of pure spectrum resolution from Raman hyperspectral images of differently manufactured pharmaceutical tablets. Anal Chim Acta 712:45–55
Xiao-fang FY, Peng-xiang Z (2004) Raman spectra of pesticides on the surface of fruits. Chin J Light Scatter 16(1):11–14
Funding
This work was supported by Innovation and Entrepreneurship Training Program for College Students of Jilin University, project no: 2018B2814.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
This article is part of the topical collection: Role of Nanotechnology and Internet of Things in Healthcare
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
This article has been retracted. Please see the retraction notice for more detail: https://doi.org/10.1007/s11051-021-05265-7
About this article
Cite this article
Jiang, Hy., Ding, Ch., Wang, Y. et al. RETRACTED ARTICLE: Determination of acetaminophen spatial distribution and content in tablets using confocal micro-Raman spectroscopy mapping. J Nanopart Res 22, 265 (2020). https://doi.org/10.1007/s11051-020-04970-z
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s11051-020-04970-z