Protective Coordination of the OCR with the Voltage Component in a Closed-Loop Power Distribution System with the FCL

  • Original Article
  • Published:
Journal of Electrical Engineering & Technology Aims and scope Submit manuscript

Abstract

Recently, the requirement of the electrical energy from the renewable source has been growing in the South Korea since government’s energy plan to generate the electrical power of 20% as renewable source. In addition, these renewable power plants have been constructed on not only the existing power plant’s side but also customer’s side. These changes in power distribution system cause the fault current to increase higher and to reverse the direction of the fault current. Variable countermeasures to reduce the fault current have been studied and the introduction of the superconducting fault current limiter (SFCL) in the power distribution system, one of them, has been actively reported. However, the installation of the SFCL can affect the power system protection because of the fault current’s decrease or increase, which depends on the construction of the power distribution system. Especially, the application of the SFCL in a closed-loop power distribution system can cause the delayed trip operation or the fast trip operation of the over-current relay (OCR), one of the representative protective devices widely used in a power distribution system. This change can influence on the existed protective coordination. In this paper, the OCR with voltage component, one of the methods to suppress its trip operation’s change in a power distribution system with a closed loop construction due to the application of the SFCL, was suggested and the protection coordination between the OCRs in a power distribution system with a closed loop was analyzed. It was confirmed that a simple using voltage component in the OCR could cause the trip variation of the reverse direction OCR in loop power system and it can be improved by matching the relaying voltage components.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Hussain S, Massoud AV (2018) Overvoltage and raised fault current issues in active distribution network. 2018 IEEE 12th International Conference on Compatibility, Power Electronics and Power Engineering, pp 1–6

  2. Blaabjerg F, Teodorescu R, Liserre M, Timbus A (2006) Overview of control and grid synchronization for distributed power generation system. IEEE Trans Ind Electron 53(5):1398–1409

    Article  Google Scholar 

  3. Hyun OB, Yim SW, Yu SD, Yang SE, Kim WS, Kim HR, Lee GH, Sim JW, Park KB (2011) Long-term operation and fault tests of a 22.9 kV hybrid SFCL in the KEPCO test grid. IEEE Trans Appl Supercond 21(3):2131–2134

  4. Huang CJ, Xiao XY, Zheng ZX, Li CS (2018) Improving LVRT capability and transient stability of MW-class PMSG with a inserted R-SFCL under grid fault. 2018 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD), pp 1–2

  5. Hartung KH, Schmidt V (2009) Limitation of short circuit current by an IS-limiter. 2009 10th International Conference on Electrical Power Quality and Utilisation, pp 1–4

  6. Lee S, Yoon J, Yang B, Moon Y, Lee B (2014) Analysis model development and specification proposal of 154 kV SFCL for the application to a live grid in South Korea. Phys C: Supercond Appl (Amsterdam, Neth) 504:148–152

    Article  Google Scholar 

  7. Lim ST, Lim SH (2017) Study on improvement of overcurrent relay (OCR)’s operation due to application of superconducting fault current limiter (SFCL) in power distribution system with a dispersed generation. Trans Korean Inst Electr Eng 66(3):300–304

    Article  Google Scholar 

  8. Kim JS, Lim SH, Kim JC (2012) Study on application method of superconducting fault current limiter for protection coordination of protective devices in a power distribution system. IEEE Trans Appl Supercond 22(3):5601504

    Article  Google Scholar 

  9. Lim ST, Lim SH (2018) Study on the OCR setting using the voltage component considering application of the SFCL in a power distribution system. Korean Inst Electr Eng 67(12):1587–1594

    Google Scholar 

  10. Saleh KA, Zeineldin HH, Al-Hinai A (2015) Optimal coordination of directional overcurrent relays using a new time–current–voltage characteristic. IEEE Trans Power Deliv 30(2):537–544

    Article  Google Scholar 

  11. Lim ST, Lim SH (2020) Analysis on operational improvement of OCR using voltage component in a power distribution system for application of SFCL. J Electr Eng Technol 14:1027–1033

    Article  Google Scholar 

  12. Lim SH, Lim ST (2019) Analysis on coordination of over-current relay using voltage component in a power distribution system with a SFCL. IEEE Trans Appl Supercond 29(5):5603605

    Article  Google Scholar 

  13. Lim ST, Lim SH (2020) Analysis on protective coordination between over-current relays with voltage component in a power distribution system with SFCL. IEEE Trans Appl Supercond 30(4):5601706

    Google Scholar 

  14. Wang W, Jazebi S, Leon FD, Li Z (2018) Looping radial distribution system using superconducting fault current limiter: feasibility and economic analysis. IEEE Trans Power Syst 33(3):2486–2495

    Article  Google Scholar 

  15. Shen KY, Gu JC (2002) Protection coordination analysis of closed-loop distribution system. Proceedings International Conference on Power System Technology 2(2):702–706

  16. Li B, Yu X, Bo Z (2009) Protection schemes for closed loop distribution network with distributed generator. 2009 International Conference on Sustainable Power Generation and Supply, pp 1–6

  17. Kim JS (2013) A study on components of MI-SFCL considering transient characteristics of circuit breaker in power system. Doctor’s thesis, Graduate School of Electrical Engineering, Soongsil University

Download references

Acknowledgements

This research was supported by Korea Electric Power Corporation (Grant number: R19XO01-19) and also supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MOE) (No. 2020R1F1A1077206).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sung-Hun Lim.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lim, ST., Lim, SH. Protective Coordination of the OCR with the Voltage Component in a Closed-Loop Power Distribution System with the FCL. J. Electr. Eng. Technol. 15, 2451–2457 (2020). https://doi.org/10.1007/s42835-020-00522-6

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s42835-020-00522-6

Keywords

Navigation