Shell and tube heat exchanger thermal-hydraulic analysis equipped with baffles and corrugated tubes filled with non-Newtonian two-phase nanofluid

Ali Akbar Abbasian Arani (Department of Mechanical Engineering, University of Kashan, Kashan, Iran)
Reza Moradi (Department of Mechanical Engineering, University of Kashan, Kashan, Iran and Department of Mechanical Engineering, Faculty of Enghelabe Eslami Branch, Technical and Vocational University (TVU), Tehran, Iran)

International Journal of Numerical Methods for Heat & Fluid Flow

ISSN: 0961-5539

Article publication date: 7 August 2020

Issue publication date: 19 March 2021

201

Abstract

Purpose

Using turbulators, obstacles, ribs, corrugations, baffles and different tube geometry, and also various arrangements of these components have a noticeable effect on the shell and tube heat exchangers (STHEs) thermal-hydraulic performance. This study aims to investigate non-Newtonian fluid flow characteristics and heat transfer features of water and carboxyl methyl cellulose (H2O 99.5%:0.5% CMC)-based Al2O3 nanofluid inside the STHE equipped with corrugated tubes and baffles using two-phase mixture model.

Design/methodology/approach

Five different corrugated tubes and two baffle shapes are studied numerically using finite volume method based on SIMPLEC algorithm using ANSYS-Fluent software.

Findings

Based on the obtained results, it is shown that for low-mass flow rates, the disk baffle (DB) has more heat transfer coefficient than that of segmental baffle (SB) configuration, while for mass flow rate more than 1 kg/s, using the SB leads to more heat transfer coefficient than that of DB configuration. Using the DB leads to higher thermal-hydraulic performance evaluation criteria (THPEC) than that of SB configuration in heat exchanger. The THPEC values are between 1.32 and 1.45.

Originality/value

Using inner, outer or inner/outer corrugations (outer circular rib and inner circular rib [OCR+ICR]) tubes for all mass flow rates can increase the THPEC significantly. Based on the present study, STHE with DB and OCR+ICR tubes configuration filled with water/CMC/Al2O3 with f = 1.5% and dnp = 100 nm is the optimum configuration. The value of THPEC in referred case was 1.73, while for outer corrugations and inner smooth, this value is between 1.34 and 1.57, and for outer smooth and inner corrugations, this value is between 1.33 and 1.52.

Keywords

Citation

Abbasian Arani, A.A. and Moradi, R. (2021), "Shell and tube heat exchanger thermal-hydraulic analysis equipped with baffles and corrugated tubes filled with non-Newtonian two-phase nanofluid", International Journal of Numerical Methods for Heat & Fluid Flow, Vol. 31 No. 4, pp. 1214-1244. https://doi.org/10.1108/HFF-04-2020-0186