To read this content please select one of the options below:

Development of medical capacitive coupling electrodes using the skin-electrode contact control

Gennadiy Evtushenko (Scientific Research Institute – Federal Research Centre for Projects Evaluation and Consulting Services, Moscow, Russian Federation)
Inna A. Lezhnina (School of Non-Destructive Testing, Tomsk Polytechnic University, Tomsk, Russian Federation)
Artem I. Morenetz (School of Non-Destructive Testing, Tomsk Polytechnic University, Tomsk, Russian Federation)
Boris N. Pavlenko (School of Non-Destructive Testing, Tomsk Polytechnic University, Tomsk, Russian Federation)
Arman A. Boyakhchyan (School of Non-Destructive Testing, Tomsk Polytechnic University, Tomsk, Russian Federation)
Stanislav N. Torgaev (School of Non-Destructive Testing, Tomsk Polytechnic University, Tomsk, Russian Federation and Faculty of Radiophysics, Tomsk State University, Tomsk, Russian Federation)
Irina Nam (School of Non-Destructive Testing, Tomsk Polytechnic University, Tomsk, Russian Federation)

Sensor Review

ISSN: 0260-2288

Article publication date: 28 April 2020

Issue publication date: 21 July 2020

113

Abstract

Purpose

The purpose of this paper is the development and study of capacitive coupling electrodes with the ability to monitor the quality of the skin–electrode contact in the process of electrocardiogram (ECG) diagnostics. The study’s scope embraces experimental identification of distortions contributed into the recorded ECG signal at various degrees of disturbance of the skin–electrode contact.

Design/methodology/approach

A capacitive coupling electrode is designed and manufactured. A large number of experiments was carried out to record ECG signals with different quality of the skin–electrode contact. Using spectral analysis, the characteristic distortions of the ECG signals in the event of contact disturbance are revealed.

Findings

It was found that the violation of the skin–electrode contact leads to significant deterioration in the recorded signal. In this case, the most severe distortions appear with various violations of the skin–electrode contact of two sensors in one lead. It has been experimentally shown that the developed sensor allows monitoring the quality of the contact, and therefore, improvement of the quality of signal registration, enabled by the use of bespoke processing algorithms.

Practical implications

These sensors will be used in personalized medicine devices and tele-ECG devices.

Originality/value

In this work, authors studied the effect of the skin–electrode contact of a capacitive electrode with the body on the quality of the recorded ECG signal. Based on the studies, the necessity of monitoring contact was shown to improve the quality of diagnostics provided by personalized medicine devices; the capacitive sensor with contact feedback was developed.

Keywords

Acknowledgements

This work was carried out with the financial support of the Russian Foundation for Basic Research in the framework of the research project no. 18-38-00535.

Citation

Evtushenko, G., Lezhnina, I.A., Morenetz, A.I., Pavlenko, B.N., Boyakhchyan, A.A., Torgaev, S.N. and Nam, I. (2020), "Development of medical capacitive coupling electrodes using the skin-electrode contact control", Sensor Review, Vol. 40 No. 3, pp. 347-354. https://doi.org/10.1108/SR-11-2019-0289

Publisher

:

Emerald Publishing Limited

Copyright © 2020, Emerald Publishing Limited

Related articles