To read this content please select one of the options below:

Research on a non-linear calibration method for dynamometer

Qingbing Chang (Dalian University of Technology, Dalian, China)
Jun Zhang (Dalian University of Technology, Dalian, China)
Zongjin Ren (Dalian University of Technology, Dalian, China)

Sensor Review

ISSN: 0260-2288

Article publication date: 9 March 2020

Issue publication date: 26 May 2020

117

Abstract

Purpose

The purpose of this paper is to solve the problem that the relationship between loading forces, which were applied at different positions on a plane, and output values of load-sharing dynamometer is non-linear.

Design/methodology/approach

First, the analytical model of ISPM (isodynamic surface proportional mapping method) method, which is used to calibrate dynamometer, was established. Then, a series of axial force calibration tests were performed on a load-sharing dynamometer at different loading positions. Finally, according to output values, calibration forces at different loading positions were calculated by ISPM method, and corresponding distribution histogram of calibration force error was generated.

Findings

The largest error between calculated force and standard force is 2.92 per cent, and the probability of calculated force error within 1 per cent is 91.03 per cent, which verify that the ISPM method is reliable for non-linear calibration of dynamometers.

Originality/value

The proposed ISPM method can achieve non-linear calibration between measured force and output signal of load-sharing dynamometer at different positions. In addition, ISPM method can also solve some complex non-linear problems, such as prediction of plane cutting force under the influence of multiple parameters, the force measurement of multi-degree-of-freedom platform and so on.

Keywords

Acknowledgements

This work is supported by the National Natural Science Foundation of China (Grant No. 51475078), the National Natural Science Foundation of China (Grant No. 51675084), the Aeronautical Science Foundation Funded Projects (No. 20160163001) and the Basic Scientific Research Project of Central University (No. DUT17GF211). The authors thank the anonymous reviewers for their helpful suggestions to improve the original manuscript.