Abstract
Concrete-filled U-shaped steel (CFUS) beam and concrete-filled steel tube (CFST) column are recently developed because of the quick construction and economical saving. This paper aims to investigate the seismic performance of a composite connection system connecting CFUS beam to square CFST columns. In the joint system, the grooved cuts on the square tube allowed the U-shaped steel beam passing through the joint core completely, which developed a through beam connection. To verify the seismic behavior of the beam-column connection, three specimens designed according to the strong column-weak beam and strong joint-weak member seismic concept were tested under combined constant axial compression and cyclic loading. For the test parameters, the different connection details and the axial load on the CFST column were considered. The test results showed that the specimens exhibited good load-carrying, deformation, and energy dissipation capacities. The maximum story drift ratio of all the three specimens was 5%, satisfying the minimum requirement of special moment frames. The primary failure mode of the specimens was local buckling of the webs and the fracture of the bottom flanges of the CFUS beam near the column tube. In addition, the joint shear strength of the specimens was evaluated based on ASCE design guidelines.
Similar content being viewed by others
References
ACI. (2011). Building code requirements for structural concrete (ACI 318-11) and commentary. ACI Committee 318, ACI.
AISC. (2005). Seismic provisions for structural steel buildings. ANSI/AISC 341-05, Chicago.
ASCE Task Committee on Design Criteria for Composite Structures in Steel and Concrete. (1994). Guidelines for design of joints between steel beams and reinforced concrete columns. Journal of Structural Engineering, 120(8), 2330–2357.
Cheng, C. T., & Chung, L. L. (2003). Seismic performance of steel beams to concrete-filled steel tubular column connections. Journal of Constructional Steel Research, 59(3), 405–426.
Chopra, A. K. (2011). Dynamics of structures (4th ed., pp. 103–105). New Jersey: Prentice Hall.
Fukumoto, T., & Morita, K. (2005). Elastoplastic behavior of panel zone in steel beam-to-concrete filled steel tube column moment connections. Journal of Structural Engineering, 131(12), 1841–1853.
GB50010. (2010). Code for design of concrete structures. Beijing: Architecture Industrial Press of China. (in Chinese).
GB50017. (2003). Code for design steel structures. Beijing: Architecture Industrial Press of China. (in Chinese).
GB50936. (2014). Technical code for concrete filled steel tubular structures. Beijing: Architecture Industrial Press of China. (in Chinese).
Hu, J. W., Kang, Y. S., Choi, D. H., et al. (2010). Seismic design, performance, and behavior of composite-moment frames with steel beam-to-concrete filled tube column connections. International Journal of Steel Structures, 10(2), 177–191.
Hwang, H., Eom, T., Park, H., Lee, S., & Kim, H. (2015). Cyclic loading test for beam-column connections of concrete-filled U-shaped steel beams and concrete-encased steel angle column. Journal of Structural Engineering, 141(11), 04015020.
JGJ/T 101-2015. (2015). Specification for seismic test for buildings (pp. 15–16). Beijing: Architecture Industrial Press of China. (in Chinese).
Kim, S. B., Ham, J. T., Lee, C. N., & Kim, S. S. (2006). Study on the structural behavior of TSC beam-to-SRC column connection. Journal of Architectural Institute of Korea, 22(6), 55–62. (In Korean).
Lee, C., Park, H., Park, C., Hwang, H., Lee, C., Kim, H., et al. (2013). Cyclic seismic testing of composite concrete-filled U-shaped steel beam to H-shaped column connections. Journal of Structural Engineering, 139(3), 360–378.
Park, R. (1988). State of the art report ductility evaluation from laboratory and analytical testing. In Proceedings of 9th world conference on earthquake engineering, Tokyo, Kyoto, Japan.
Park, H. G., Hwang, H. J., Lee, C. H., et al. (2012). Cyclic loading test for concrete-filled U-shaped steel beam–RC column connections. Engineering Structures, 36, 325–336.
Zhou, Z. H., Zhou, Z., & Gan, D. (2018). Cyclic testing of square tubed-reinforced-concrete column to RC beam joints. Engineering Structures, 176, 439–454.
Acknowledgements
Chongqing Yujian Industrial Group Co., Ltd. financially supported the study. In addition, the authors are grateful to the authorities for their support.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Xu, X., Cheng, R., Yang, P. et al. Cyclic Loading Test for Concrete-Filled U-Shaped Steel Beam to Concrete-Filled Steel Tube Column Connections. Int J Steel Struct 20, 1859–1870 (2020). https://doi.org/10.1007/s13296-020-00378-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13296-020-00378-6