Abstract

Measuring 87Sr/86Sr ratios with MC-ICP-MS is a straightforward technique due to its fast sample introduction. However, excellent accuracy and precision cannot be easily achieved unless careful optimization of plasma running conditions and evaluation of instrumental mass bias are conducted. Here, we developed an optimized protocol for measuring 87Sr/86Sr ratios using a modified cone arrangement (H skimmer cone + Jet sample cone) by carefully examining the effects of plasma working conditions on the performance of Sr isotope analysis with a Neptune Plus™ MC-ICP-MS. The modified cone arrangement significantly enhanced the Sr signal sensitivities by a factor of 2, compared to the standard cone arrangement (H skimmer cone + standard sample cone). For both cone arrangements, the mass bias of Sr isotopes fits the standard exponential law under optimal conditions. However, at non-optimum sample gas flow rates, the corrected 87Sr/86Sr ratios deviated from the reference value, and thus non-linear mass bias was observed. Such mass bias could not be corrected using the standard exponential law. This observation cautioned researchers analyzing Sr ratios at optimized sample gas flow rates when using MC-ICP-MS. With further evaluation of the sample concentration, integration time and interference element correction, 87Sr/86Sr ratio analysis with high accuracy and precision was achieved. Excellent results of the reference materials were obtained using the optimized protocol. Compared to the classical TIMS technique, our method is comparable in precision (∼8 × 10−6, 2SE) but much faster in operation (14 minutes per analysis), and therefore is a technical advance in Sr isotope geochemistry.

Graphical abstract: An optimized protocol for high precision measurement of 87Sr/86Sr using a Neptune Plus multi-collector inductively coupled plasma mass spectrometer: evaluation of different cone combinations for Sr isotope determination

Supplementary files

Article information

Article type
Technical Note
Submitted
27 Apr 2020
Accepted
07 Jul 2020
First published
08 Jul 2020

Anal. Methods, 2020,12, 4089-4096

An optimized protocol for high precision measurement of 87Sr/86Sr using a Neptune Plus multi-collector inductively coupled plasma mass spectrometer: evaluation of different cone combinations for Sr isotope determination

T. Zhou, L. Qi, H. Fan and R. Yin, Anal. Methods, 2020, 12, 4089 DOI: 10.1039/D0AY00845A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements