Abstract
The aim of this study was to investigate the treatment and reuse of laundry wastewater with couple of nanofiltration (NF) and reverse osmosis (RO). In the NF process, optimal values of pH, temperature, transmembrane pressure (TMP) and cross-flow rate were determined using the Taguchi L16 (44) experimental design method. The smaller-the-better signal-to-noise (S/N) ratio was used to analyze the results of experiments. Flux decline caused by fouling was selected as response parameter. A pH of 8.5, temperature of 30 °C, TMP of 12 bar and cross-flow rate of 2 L/min were determined as optimum operating conditions in the NF process. According to analysis of variance (ANOVA), pH was the most effective factor while TMP and cross-flow rate had low effects on the fouling. Membrane fouling was also evaluated with scanning electron microscope (SEM), energy dispersive X-ray spectroscopy (EDX), zeta potential and optical profilometer measurements. In the RO process, the quality of NF permeate obtained from optimum operating conditions was improved by an RO membrane. Although a NF membrane was not effective in reducing chemical oxygen demand (COD), Orto-P and NH4+-N, these parameters were almost removed in the NF + RO system. These results showed that, the Taguchi method was successfully applied to determine the optimum operating conditions for the treatment of laundry wastewater with an NF process. Water treated with integrated membrane processes (NF + RO) is sufficient for use as laundry washing water.
Similar content being viewed by others
References
Ciabatti I, Cesaro F, Faralli L, Fatsrella E, Tognotti F. Demonstration of a treatment system for purification and reuse of laundry wastewater. Desalination. 2009;245:451–9.
Misra KR, Patel JH, Baxi VR. Reuse potential of laundry for irrigation based on growth, water and nutrient use of tomato. J Hydrol. 2010;386:95–102.
Janpoor F, Torabian A, Khatibikamal V. Treatment of laundry wastewater by electrocoagulation. J Chem Technol Biotechnol. 2011;86:1113–20.
Kim H-C, Shang X, Huang J-H, Dempsey BA. Treating laundry wastewater: cationic polymers for removal of contaminants and decreased fouling in microfiltration. J Membr Sci. 2014;456:167–74.
Šostar-Turk S, Petrinić I, Simonič M. Laundry wastewater treatment using coagulation and membrane filtration. Resour Conserv Recy. 2005;44:185–96.
Hoinkis J, Panten V. Wastewater recycling in laundries-from pilot to large-scale plant. Chem Eng Process. 2008;47:1159–64.
Misra KR, Sivongxay A. Reuse of laundry greywater as affected by its interaction with saturated soil. J Hydrol. 2009;366:55–61.
Guilbaud J, Massé Andrès Y, Combe F, Jaouen P. Laundry water recycling in ship by direct nanofiltration with tubular membranes. Resour Conserv Recy. 2010;55:148–54.
Manouchehri M, Kargari A. Water recovery from laundry wastewater by the cross-flow microfiltration process: a strategy for water recycling in residential buildings. J Clean Prod. 2017;168:227–38.
Bering S, Mazur J, Tarnowski K, Janus M, Mozia S, Morawski AW. The application of moving bed bio-reactor (MBBR) in commercial laundry wastewater treatment. Sci Total Environ. 2018;627:1638–43.
Choobar BG, Shahmirzadi MAA, Kargari A, Manouchehri M. Fouling mechanism identification and analysis in microfiltration of laundry wastewater. J Environ Chem Eng. 2019;7:103030.
de Faria CV, Delferno TP, Okada DY, Varesche MBA. Evaluation of anionic surfactant removal by anerobic degradation of commercial laundry wastewater and domestic sewage. Envr Technol. 2019;40:988–96.
Gönder ZB, Arayici S, Barlas H. Advanced treatment of pulp and paper mill wastewater by nanofiltration process: effects of operating conditions on membrane fouling. Sep Purif Technol. 2011;76:292–302.
Hepsen R, Kaya Y. Optimization of membrane fouling using experimental design:an example from dairy wastewater treatment. J Ind Eng Chem. 2012;51:16074–84.
Qusay FA, Salah SI, Fatima AH. Experimental and theoretical investigation of air gap membrane distillation process for water desalination. Chem Eng Res and Des. 2018;130:95–108.
APHA/AWWA/WEF Standard Methods for the Examination of Water and Wastewater, American Public Health Association, Washington DC, USA, ISBN 0–87553–223-3. 1995.
European norm, ISO 7887 Water quality examination and determination of color, Brussels. 1994.
DIN 38404-C3, Deutsche einheitsverfahren zur wasser-, abwasserund schlammuntersuchung- physikalisch-chemische kenngrößen (gruppe C) - teil 35: bestimmung der absorption im bereich der UV-strahlung spektraler sbsorptionskoeffizient (C3); Beuth Verlag: Berlin 2003.
Aber S, Salari D, Parsa MR. Employing the Taguchi method to obtain the optimum conditions of coagulation-flocculation process in tannery wastewater treatment. Chem Eng J. 2010;162:127–34.
Safarzadeh MS, Moradkhani D, Ilkhchi MO, Golshan NH. Determination of the optimum conditions for the leaching of cd–Ni residues from electrolytic zinc plant using statistical design of experiments. Sep Purif Technol. 2008;58:367–76.
Çopur M, Özmetin C, Özmetin E, Kocakerim MM. Optimization study of the leaching of roasted zinc sulphide concentrate with sulphuric acid solutions. Chem Eng Process. 2004;43:1007–14.
Yang J, Lee S, Lee E, Lee J, Hong S. Effect of solution chemistry on the surface property of reverse osmosis membranes under seawater conditions. Desalination. 2009;247:148–61.
Li K, Ma W, Han H, Xu C, Zhu H. Selective recovery of salt from coal gasification brine by nanofiltration membranes. J Environ Manag. 2018;223:306–13.
Kenneth SYN, Malavika H, Dalton JEH, Dave ED, Gregory JO. Mechanisms of flux decline in skim milk ultrafiltration: a review. J Membr Sci. 2017;523:144–62.
Montgomery DC. Design and analysis of experiments. 5th. ed. Newyork: John Wiley; 2001.
Pulido JMO, Férez AM. Impacts of operating conditions on nanofiltration of secondary-treated two-phase olive mill wastewater. J Environ Manag. 2015;161:219–27.
Acknowledgements
This work was supported by the Research Fund of the Istanbul University-Cerrahpasa (Project number: 25868).
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Kaya, Y., Dayanir, S. Application of nanofiltration and reverse osmosis for treatment and reuse of laundry wastewater. J Environ Health Sci Engineer 18, 699–709 (2020). https://doi.org/10.1007/s40201-020-00496-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s40201-020-00496-7