Study on safe distance between human body and wireless charging system of electric vehicles with different power and frequencies

  • Original Paper
  • Published:
Electrical Engineering Aims and scope Submit manuscript

Abstract

In this paper, a wireless charging system and a human body model with various operating frequencies and output power are constructed to study the safe distance between the human body and the charging system when the electric vehicle is wirelessly charging. The models are simulated for electromagnetic fields and electromagnetic thermal effects. This paper mainly focuses on the induced electric field intensity of the human body and main organs during the static charging of electric vehicles under different operating conditions in a wireless charging system. The results are compared with the standards established by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) to derive the minimum safe distance for electric vehicles charged wirelessly. The results show that when the system works at a frequency of 85 kHz with output power of 3.7 kW, 7.7 kW, 22 kW, 33 kW, 66 kW, and 150 kW, the minimum safe distance between the human body and the system is 0.5 m, 0.6 m, 0.7 m, 1.0 m, 1.2 m, and 1.7 m; when the system works at an output power of 66 kW with frequency of 85 kHz, 300 kHz, 500 kHz, and 700 kHz, the corresponding minimum safe distance is 1.2 m,0.9 m, 0.8 m, and 0.6 m. Moreover, the induced electric field intensity distribution of human organs at different power is also calculated, and the results show that the induced electric field intensity of the liver and kidney is higher than that of other organs. When the human body is at the minimum safe distance, the temperature changes caused by the electromagnetic heating effect of various organs are within the normal adjustment range of the human body, indicating the rationality of the minimum safe distance when the electric vehicle wireless charging system works under parameters of this paper. It provides a theoretical basis for the setting of the safe distance of the electric vehicle wireless charging system.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
Fig. 20
Fig. 21
Fig. 22
Fig. 23
Fig. 24
Fig. 25
Fig. 26

Similar content being viewed by others

References

  1. Ahmad A, Alam MS, Chabaan R (2018) A comprehensive review of wireless charging technologies for electric vehicles. IEEE Trans Transp Electrif 4(1):38–63. https://doi.org/10.1109/tte.2017.2771619

    Article  Google Scholar 

  2. Koerner A, Turki F (2014) Compact, Safe and Efficient Wireless and Inductive Charging for Plug-In Hybrids and Electric Vehicles. In: Fischer-Wolfarth J, Meyer G (eds) Advanced microsystems for automotive applications 2014: smart systems for safe, clean and automated vehicles. Lecture Notes in Mobility. pp 213–234. https://doi.org/10.1007/978-3-319-08087-1_20

  3. Cui S, Liu ZZ, Hou YJ, Zeng H, Yue ZK, Liang LH (2017) Study on efficiency of different topologies of magnetic coupled resonant wireless charging system. In: Kyriakopoulos GL (ed) 2017 International Conference on New Energy and Future Energy System, vol 93. IOP Conference Series-Earth and Environmental Science. IOP Publishing Ltd, Bristol. https://doi.org/10.1088/1755-1315/93/1/012064

  4. Li WH, Zhao H, Li SQ, Deng JJ, Kan TZ, Mi CC (2015) Integrated LCC compensation topology for wireless charger in electric and plug-in electric vehicles. IEEE Trans Ind Electron 62(7):4215–4225. https://doi.org/10.1109/tie.2014.2384003

    Article  Google Scholar 

  5. Zhao J, Xu G, Zhang C, Zhang W, Li X (2012) A Contrastive Studies between Magnetic Coupling Resonance and Electromagnetic Induction in Wireless Energy Transmission. In: IEEE. https://doi.org/10.1109/icef.2012.6310324

  6. Yin X, Wang X, He P (2018) Simulation analysis and research of magnetic coupling resonant wireless power transmission system. In: IEEE. https://doi.org/10.1109/icitbs.2018.00199

  7. Liao ZJ, Sun Y, Xia CY, Wu XJ (2009) A methodology to achieve the maximum transfer efficiency for magnetic coupling wireless power transfer systems. Electr Eng. https://doi.org/10.1007/s00202-019-00858-x

    Article  Google Scholar 

  8. Zhao JB, Cai T, Duan SX, Feng H, Chen CS, Zhang XM (2016) A general design method of primary compensation network for dynamic WPT system maintaining stable transmission power. IEEE Trans Power Electron 31(12):8343–8358. https://doi.org/10.1109/tpel.2016.2516023

    Article  Google Scholar 

  9. Zhang YM, Zhao ZM, Chen KN (2014) Frequency decrease analysis of resonant wireless power transfer. IEEE Trans Power Electron 29(3):1058–1063. https://doi.org/10.1109/tpel.2013.2277783

    Article  Google Scholar 

  10. Campi T, Cruciani S, De Santis V, Feliziani M (2016) EMF safety and thermal aspects in a pacemaker equipped with a wireless power transfer system working at low frequency. IEEE Trans Microw Theory Tech 64(2):375–382. https://doi.org/10.1109/tmtt.2015.2514087

    Article  Google Scholar 

  11. Kurs A, Karalis A, Moffatt R, Joannopoulos JD, Fisher P, Soljacic M (2007) Wireless power transfer via strongly coupled magnetic resonances. Science 317(5834):83–86. https://doi.org/10.1126/science.1143254

    Article  MathSciNet  Google Scholar 

  12. Carpenter DO (2013) Human disease resulting from exposure to electromagnetic fields. Rev Environ Health 28(4):159–172. https://doi.org/10.1515/reveh-2013-0016

    Article  Google Scholar 

  13. Li Y, Wang W, Xing L, Fan Q, Wang H (2018) Longitudinal safety evaluation of electric vehicles with the partial wireless charging lane on freeways. Accid Anal Prev 111:133–141. https://doi.org/10.1016/j.aap.2017.11.036

    Article  Google Scholar 

  14. Higaki N, Shiba K (2010) Analysis of specific absorption rate and current density in biological tissues surrounding energy transmission transformer for an artificial heart: using magnetic resonance imaging-based human body model. Artif Organs 34(1):E1–E9. https://doi.org/10.1111/j.1525-1594.2009.00916.x

    Article  Google Scholar 

  15. Christ A, Douglas MG, Roman JM, Cooper EB, Sample AP, Waters BH, Smith JR, Kuster N (2013) Evaluation of wireless resonant power transfer systems with human electromagnetic exposure limits. IEEE Trans Electromagn Compat 55(2):265–274. https://doi.org/10.1109/temc.2012.2219870

    Article  Google Scholar 

  16. Nagaoka T, Watanabe S, Niwa T, IEEE (2014) Numerical Modeling and Dosimetry of Pregnant Females at Various Stages of Pregnancy. In: 2014 International Symposium on Electromagnetic Compatibility, Tokyo. IEEE International Symposium on Electromagnetic Compatibility. IEEE, New York, pp 190–193

  17. Tanaka N, Hikage T, Corcoles J, Nojima T, IEEE (2016) FEM simulation of induced interference voltage at implantable cardiac pacemaker due to wireless power transfer in HF-band. In: 2016 International Symposium on Antennas and Propagation. IEEE, New York

  18. Chakarothai J, Wake K, Arima T, Watanabe S, Uno T (2018) Exposure evaluation of an actual wireless power transfer system for an electric vehicle with near-field measurement. IEEE Trans Microw Theory Tech 66(3):1543–1552. https://doi.org/10.1109/tmtt.2017.2748949

    Article  Google Scholar 

  19. Wireless Power Transfer for Light-Duty Plug-In/Electric Vehicles and Alignment Methodology, Standard SAE J2954, 2016.

  20. Ziegelberger G, Int Commission Nonionizing R (2009) ICNIRP statement on the "Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 ghz)". Health Phys 97(3):257–258

    Article  Google Scholar 

  21. Int Commission N-I (2010) ICNIRP statement-guidelines for limiting exposure to time-varying electric and magnetic fields (1 hz to 100 khz). Health Phys 99(6):818–836. https://doi.org/10.1097/HP.0b013e3181f06c86

    Article  Google Scholar 

  22. Gabriel S, Lau RW, Gabriel C (1996) The dielectric properties of biological tissues: II Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol 41(11):2251–2269. https://doi.org/10.1088/0031-9155/41/11/002

    Article  Google Scholar 

Download references

Acknowledgements

The authors wish to thank for the support of the National Natural Science Foundation of China under Grant 51407058.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jun Zhao.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhao, J., Wu, ZJ., Li, NL. et al. Study on safe distance between human body and wireless charging system of electric vehicles with different power and frequencies. Electr Eng 102, 2281–2293 (2020). https://doi.org/10.1007/s00202-020-01026-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00202-020-01026-2

Keywords

Navigation