A Class-E Power and Data Transmitter with On–Off Keying Data Modulation for Wireless Power and Data Transmission to Medical Implants

  • Short Paper
  • Published:
Circuits, Systems, and Signal Processing Aims and scope Submit manuscript

Abstract

This paper presents a new on–off keying modulation circuit for a Class-E power transmitter used in high-data-rate wireless links used for powering medical implants. A circuit technique is proposed to keep the current of the RF choke of the power transmitter constant, while the transmitter turns on and off. This allows the transmitter to quickly turn on and off. To prove the feasibility of the proposed circuit, a wireless power and data transfer link based on the proposed circuit was designed and implemented. At a carrier frequency of 2.5 MHz, the measured data rate was 625 kbps, which means that a data-rate-to-carrier-frequency ratio of 25% has been achieved. The power transfer efficiency and the power delivered to the load, with a 2.37-μH transmitter coil and a 1.4-μH receiver coil separated by a 1.0-cm air gap, were measured to be 21% and 80 mW, respectively. The measured bit error rate of the link was less than 10−5.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. M.M. Ahmadi, S. Ghandi, A Class-E power amplifier with wideband FSK modulation for inductive power and data transmission to medical implants. IEEE Sens. J. 18(17), 7242–7252 (2018)

    Article  Google Scholar 

  2. M. Catrysse, B. Hermans, R. Puers, An inductive power system with integrated bi-directional data-transmission. Sens. Actuators A Phys. 115(2–3), 221–229 (2004)

    Article  Google Scholar 

  3. M. Ghovanloo, K. Najafi, A wideband frequency-shift keying wireless link for inductively powered biomedical implants. IEEE Trans. Circuits Syst. 51, 2374–2383 (2004)

    Article  Google Scholar 

  4. M.A. Hannan, S.M. Abbas, S.A. Samad, A. Hussain, Modulation techniques for biomedical implanted devices and the challenges. Sensors 12, 297–319 (2012)

    Article  Google Scholar 

  5. R.D. Jesme, Transmitter Modulation. US Patent 6737973, (2004)

  6. M.K. Kazimierczuk, RF power transmitters, 2nd edn. (Wiley, Hoboken, 2015)

    Google Scholar 

  7. J.C. Lin, Coupling of electromagnetic fields into biological systems, in Electromagnetic Fields in Biological Systems, ed. by James C. Lin (CRC Press, Boca Raton, FL, 2012)

    Google Scholar 

  8. M. Monge et al., A fully intraocular high-density self-calibrating epiretinal prosthesis. IEEE Trans Biomed Circuits Syst 7(6), 747–760 (2013)

    Article  Google Scholar 

  9. J. Olivo, S. Carrara, G.D. Micheli, A study of multi-layer spiral inductors for remote powering of implantable sensors. IEEE Trans. Biomed. Circuits Syst. 7(4), 536–547 (2013)

    Article  Google Scholar 

  10. A. Rush, P. Troyk, A power and data link for a wireless-implanted neural recording system. IEEE Trans. Biomed. Cir. Syst. 59, 3255–3262 (2012)

    Article  Google Scholar 

  11. S. Shahsavari, M. Saberi, A power-efficient CMOS active rectifier with circuit delay compensation for wireless power transfer systems. Circuits Syst Signal Process. 38, 947 (2019). https://doi.org/10.1007/s00034-018-0902-9

    Article  Google Scholar 

  12. N.O. Sokal (2001) Class-E RF power transmitters. QEX magazine

  13. N. Tran et al., A complete 256-electrode retinal prosthesis chip. IEEE J. Solid-State Circuits 49(3), 751–765 (2014)

    Article  Google Scholar 

  14. B.H. Waters et al., Optimal coil size ratios for wireless power transfer applications. Proceedings of the 2003 IEEE International Symposium on Circuits and Systems (2014). p. 2045--2048

  15. F.G. Zeng, S. Rebscher, W. Harrison, X. Sun, H. Feng, Cochlear implants: system design, integration, and evaluation. Rev. Biomed. Eng. 1, 115–142 (2008)

    Article  Google Scholar 

  16. F.G. Zeng et al., Development and evaluation of the Nurotron 26-electrode cochlear implant system. Elsevier Hear. Res. J. 322, 188–199 (2015)

    Article  Google Scholar 

  17. C.M. Zierhofer, I.J. Hochmair-Desoyer, E.S. Hochmair, Electronic design of a cochlear implant for multichannel high-rate pulsatile stimulation strategies. IEEE Trans. Rehabilit. Eng. 3(1), 112–116 (1995)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mohammad Mahdi Ahmadi.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ahmadi, M.M., Sarbandi-Farahani, M. A Class-E Power and Data Transmitter with On–Off Keying Data Modulation for Wireless Power and Data Transmission to Medical Implants. Circuits Syst Signal Process 39, 4174–4186 (2020). https://doi.org/10.1007/s00034-020-01362-5

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00034-020-01362-5

Keywords

Navigation