Introduction

Phosphorus (P) is one of the main fertilizers used in agriculture. However, excess P losses from agricultural areas to receiving water bodies can cause water quality impairments. It has been shown that field and lake percentages as well as soil type strongly control total phosphorus (TP) loss from catchments in Finland (Röman et al. 2018; Vuorenmaa et al. 2002). Thus, TP transported in rivers is often monitored to evaluate excess P losses and the effectiveness of mitigation measures intended to constrain P losses from agricultural sites (e.g., Tattari et al. 2017). TP can be divided into two operational fractions: total dissolved phosphorus (TDP) and particulate phosphorus (PP = TP ˗ TDP) (Haygarth and Sharpley 2000). PP is usually the dominant fraction in field runoff from drained clay soils (Ulén and Persson 1999).

In situ measured turbidity (TURB) has been used as a surrogate for TP or PP in several studies (Grayson et al. 1996; Hopkins et al. 2017; Horsburgh et al. 2010; Lannergård et al. 2019; Spackman Jones et al. 2011; Stubblefield et al. 2007; Valkama and Ruth 2017; Villa et al. 2019). Recent studies have suggested that the river nutrient load is better captured with high-frequency optical sensors than with low-frequency water sampling combined with continuous discharge data (Stutter et al. 2017; Valkama and Ruth 2017). However, TP flux estimation associated with storm flow events is highly sensitive to local sensor calibration, i.e., conversion of sensor turbidity values into P concentrations (Lannergård et al. 2019). Thus, site-specific local calibration of the raw data of the optical sensors into representative turbidity units or water quality concentrations is needed depending on the sensor used and is mandatory when surrogates are used. Automatic water sample collection based on flow rate changes or on preset water quality conditions provides a good surrogate relationship according to Minaudo et al. (2017) and Melcher and Horsburgh (2017). However, autosamplers are typically available only at a few monitoring sites, and large flow peaks are often missed by manual sampling, especially if hydrograph slopes are steep. Despite the existence of published guidelines for in situ data processing (e.g., Pellerin et al. 2013), there is a need to define practices regarding how to conduct the efficient sampling needed for local calibration by minimising costs and achieving acceptable accuracy in the resulting water quality and nutrient yield estimates (Horsburgh et al. 2010).

Turbidity is a suitable surrogate for TP only if a reasonable relationship between these constituents is found (Villa et al. 2019). The physicochemical properties of suspended sediment impact the capacity of suspended solids to transport PP, which is largely site dependent and varies temporally (House and Denison 2002; Van der Perk et al. 2007). Factors such as land management may introduce additional variations to the relationship between TP and turbidity. Local assessment of the appropriateness of surrogate relationships between turbidity and TP has been stressed in several studies (e.g., Grayson et al. 1996; Ruzycki et al. 2014). Stutter et al. (2017) concluded that the surrogate relationship between PP and turbidity was not transferable to a neighbouring catchment with similar soils and land cover. In addition, the particle size distribution of suspended sediments and bedload can be different in low- and high-flow situations (Pfannkuche and Schmidt 2003) and may impact the relationship between turbidity and TP. In some sites, there is a positive relationship between TP concentration and the specific surface area of suspended sediments (Evans et al. 2004). Thus, for example, the storm-related TP concentration in suspended solids can be much higher during the rising limb of the hydrograph compared with the falling limb or baseflow (Evans et al. 2004). Nonlinearity and hysteresis effects were taken into account by Minaudo et al. (2017), who found more reliable TP load estimates than those calculated with a linear surrogate relationship between TP and turbidity. The seasonal variation in the relationship between TP concentration and suspended sediments, as well as differences in P retention mechanisms, between two rivers, was reported by Evans et al. (2004). Differences in the storm-related concentration-discharge responses of TP and unfiltered molybdate-reactive P may be explained by the surface and subsurface transport of P fractions and the wetness of the catchment (Outram et al. 2014). Dissolved P loading may originate from scattered sources, such as fields with high soil P levels (Uusitalo et al. 2007), livestock grazing and manure spreading or point sources.

The TDP/TP ratio may vary interannually and depend on catchment properties (Johnes 2007). Thus, variations in the TDP/TP ratio may degrade the usability of turbidity as a surrogate for TP. Consequently, the uncertainty of TP estimates using turbidity as a proxy needs to be better quantified. To improve TP and PP estimates with a turbidity surrogate, additional surrogate constituents or explanatory variables such as snowmelt, discharge, orthophosphorus, chlorophyll A or chloride have been suggested by Spackman Jones et al. (2011) and Schilling et al. (2017). Haygarth et al. (2005) suggested that with care in calibration, turbidity could potentially act as a surrogate for PP in stormflows; thus, we study both TP’s and PP’s relationship with turbidity.

Often, the constraint in local sensor calibration is that high flow situations are rarely sampled in regular monitoring, especially when the hydrograph slopes are steep. We test a novel and cost-effective practice to utilize the available long-term river water quality monitoring data collected prior to sensor deployment as reference data for local calibration. In optimal situations, this may provide additional confidence in site-specific local sensor calibration. The objectives of the study are as follows:

  1. 1)

    To evaluate the performance of in situ UV-Vis sensors in four river basins to produce turbidity, TP and PP estimates.

  2. 2)

    To determine how turbidity acts as a surrogate for PP and TP using long-term laboratory data.

  3. 3)

    To quantify the effect of potentially influential samples on TP concentration estimates due to changes in the local calibration equations of the UV-Vis sensors.

  4. 4)

    To test the transferability of a local TP calibration equation of a UV-Vis sensor.

  5. 5)

    To evaluate the impact of TDP on the surrogate relationship between turbidity and TP.

Study areas

Four rivers from Southwest Finland were selected based on their in situ water quality, data availability and representativeness of the area and size. The basin sizes varied from smaller sub-basins (15–233 km2) to larger main basins (727–1317 km2) (Table 1). The large rivers of Aurajoki and Eurajoki flow into the Baltic Sea. The Savijoki River is a small tributary of the Aurajoki River, whereas the Yläneenjoki River belongs to the Eurajoki basin and flows into Lake Pyhäjärvi (154 km2), which is the source of the Eurajoki River and accounts for 25% of the Eurajoki basin.

Table 1 Study area characteristics. Land classification is largely based on the 2012 CORINE land cover classification, and the soil types were obtained from a digital soil map (1:200,000; Lilja et al. 2006). Dominant crop types were obtained from a parcel register owned by the Agency for Rural Affairs

Most of the agricultural land of the Aurajoki and Savijoki basins is classified as a Vertic Cambisol (75%), which is a highly erodible soil. Thus, the river water in these two rivers is highly turbid (Fig. A1). Agricultural fields in the Savijoki area are steeper than those in the entire Aurajoki area. These catchments do not include any large lakes. The Aurajoki catchment is representative of watersheds located in Southwest Finland.

The Yläneenjoki and Eurajoki rivers represent chained river-lake systems. In the Yläneenjoki catchment, the share of agricultural land is slightly smaller than that at the Aurajoki site, while in the Eurajoki catchment, the share is even lower (Table 1). In these catchments, the main soil types are Haplic Podzols and Lithic Leptosols and thus different compared with those of the Aurajoki and the Savijoki catchments. The turbidity level is the lowest in the Eurajoki basin. On the coastal plains of western Finland, acid sulphate soils in former sea bed areas are common. Some agricultural land areas in the Eurajoki basin are classified as acid sulphate soils, which are highly productive. Periodically, high acidity and high concentrations of sulphate and metals are associated with stream waters affected by acid sulphate soils (Nyberg et al. 2012). Vuorenmaa et al. (2002) studied small agricultural catchments and found that losses of TP were lower from agricultural acid sulphate soils compared with clayey agricultural soils. Thus, the low field percentage and acid sulphate soils in Eurajoki seem to explain the low TP and PP concentrations there compared with other sites.

In Southwest Finland, the average annual rainfall is 723 mm years−1 (1981–2010), and the mean air temperature is 5.5 °C (Pirinen et al. 2012). The median TP concentrations (Table 1) indicate poor chemical status for the Aurajoki, Savijoki and Yläneenjoki rivers, whereas the chemical status based on TP concentration is good in Eurajoki (Aroviita et al. 2012). However, the ecological status of Eurajoki is moderate based on data from 2012 to 2017. Long-term laboratory data indicate that on average, more than 70% of TP is in particulate form in the studied rivers (Fig. A1). Earlier studies provided information on the P loading of the Eurajoki and Yläneenjoki (Koskiaho et al. 2010; Ventelä et al. 2007), Aurajoki (Korppoo et al. 2017) and Savijoki (Granlund et al. 2005; Rekolainen et al. 1991; Tattari et al. 2017) rivers.

Data and methods

Discrete water samples and laboratory analyses

The water monitoring interval ranged from subdaily to once-a-month sampling. Routine water quality surveillance was conducted over the period 1990–2017. At Savijoki, an automated water sampler was occasionally applied from 2007 to 2009. At the Eurajoki site, water samples were not collected regularly prior to the in situ sensor installation in 2009; thus, long-term monitoring data were not available from that site.

Standardized methods were used in chemical analyses, and we applied P fraction classification according to Haygarth and Sharpley (2000) (Table A1). TP was determined colourimetrically by the molybdenum blue method (Murphy and Riley 1962) using ascorbic acid as a reductant and the digestion of organic P compounds with potassium peroxodisulphate. TDP was determined similarly to TP, but the samples were filtered first using Nuclepore polycarbonate membranes with a 0.4 μm pore size. PP was obtained by subtracting TDP from TP. The nephelometric method was applied for turbidity laboratory analyses. TP, TDP and turbidity data were retrieved from the open source database of the Finnish Environment Institute (www.syke.fi/en-US/Open_information). The long-term monitoring data were used to evaluate the feasibility of building linear least square TP or PP estimation models with turbidity as a surrogate. In addition, the laboratory data were used in the local calibration of the sensors.

In situ optical turbidity measurements

We used s::can UV-Vis spectrophotometers (s::can Messtechnik GmbH, Austria) to measure light absorbance in the wavelength range from 220 to 720 nm. The manufacturer has defined global algorithms that interpret the absorbance spectrum introduced by turbid matter in water, which enables the spectrophotometer to produce raw turbidity values. In the case of s::can sensors, a site-specific local calibration is needed to convert raw units into representative turbidity values. The sensors were measured at 30-min intervals during the following periods: January 2010 to September 2013 (Aurajoki, Site 1), August 2009 to September 2013 (Savijoki, Site 2), June 2009 to December 2015 (Eurajoki, Site 3) and November 2013 to December 2015 (Yläneenjoki, Site 4). A few short periods existed when sensor data were not retrieved for Eurajoki. The sensor at Aurajoki was removed from the river for the ice clearance periods of spring 2010 and 2011 to avoid damage to the instrument. The optical path lengths of the sensors were either 2 mm (Sites 1 and 4) or 5 mm (Sites 2 and 3). The accuracy of a 2 mm sensor for raw turbidity values is ± 12 units, and for 5 mm sensors, it is ± 3 units, based on measurement experience in Finnish rivers. The optimal turbidity measurement ranges of the 2 mm and 5 mm sensors are 0–1000 FNU and 0–2500 FNU, respectively. The spectrophotometers used simultaneously measure turbidity and nitrate nitrogen. The optical path length of each spectrophotometer is such that the device is capable of measuring both turbidity and nitrate nitrogen as well as possible, taking into account the water quality of the river. All probes are equipped with automatic compressed air cleaning operating every other hour. Manual cleaning was conducted at least fortnightly during the growing season and every 3 weeks during the cold season. Baseline checking for the spectrometers was performed with Milli-Q water once a year. Degradation of the sensor lamps, which were no more than 6 years old, was not detected at baseline.

In quality control, the sensor data were visually inspected to detect data gaps and anomalies. Water and air temperature time series, as well as water level fluctuation, sensor nitrate nitrogen reading, and sensor maintenance notes, were used in the quality control. Sensor data spikes, e.g., due to icing or biological disruption, were detected and removed from the raw data time series. A few outliers were also removed from the laboratory data when the ratio of analysed P to turbidity was abnormal. After outlier removal, we were able to perform the local sensor calibration and match quality-controlled raw sensor turbidity values with discrete laboratory-determined water quality data. The water samples used in the calibration were collected as close as possible to the sensors. The potential time difference between grab sampling and sensor reading was resolved by pairing the discrete samples with the nearest sensor reading in time.

Statistical analysis

Prior to analysis, two-way relationships between TP or PP and turbidity were examined. Based on scatterplots, linearity of the relationships between variables was assumed, and simple linear regression models were fitted to the data. The models are in the form y = αx + β, where TP or PP is the response (y) variable, turbidity is the explanatory (x) variable, and α and β are the slope and the intercept of the regression line, respectively. Normality, heteroscedasticity and independency of the model residuals were tested and found not to drastically violate the regression model assumptions. This means that the standardized residuals are symmetrically distributed, they are not clustered in any way and they do not show any clear patterns. In general, when the models are used purely for predictions, slight violations of the model assumptions are not considered a significant problem (Kutner et al. 2004).

Several goodness-of-fit statistics were used to evaluate the performance of the models (Table A2). The coefficient of determination (R2) was used to assess how well the model fits the data or how strong the linear relationship is between values. The model standard percentage error (MSPE) and relative percentage difference (RPD) were used to assess the linear regression models. RPD was calculated between estimated values and laboratory-determined values. MSPE and RPD can be used to compare separate regression models (Rasmussen et al. 2009) since these standardized statistics are independent of the mean concentration (Hardison 1969). The range of a value plus or minus twice the RMSE produces the 95% confidence limits for the prediction of the response variable (Kleinbaum and Kupper 1978). Spearman’s correlation (rs) was used to assess the relationship between laboratory-determined TP or PP and turbidity. Simple linear regression models between TP or PP and turbidity were formed using

  1. i)

    sensor deployment period laboratory data and raw turbidity sensor data (i.e., local calibration)

  2. ii)

    long-term laboratory data

  3. iii)

    sensor deployment period laboratory data

In local calibration (i), it is especially important that the sample size is sufficiently large with respect to the measurement range, and the samples represent the whole flow or turbidity range (Pellerin et al. 2013). Using long-term laboratory data (ii), it is possible to determine whether turbidity acts better as a surrogate for PP than for TP. We hypothesise that the larger amount of long-term data and potentially more representative long-term data would provide more insight into the relationship of the water quality constituents. A comparison between regressions ii and iii is made to explore whether the resulting regressions based on different amounts of data are similar. In that case, the local sensor calibration might be applicable to a wider P concentration range than the discrete samples of the sensor deployment period.

Linear regression models can be sensitive to observations that diverge from the overall pattern in sample data. These so-called influential observations are not erroneous but true extreme values that have an effect on the model slope. This in turn has an influence on the estimates (e.g., the estimates of TP and PP in this case). We identify visually potentially influential data pairs and use Cook’s distance (Di) (Cook 1977) to quantify their potential influence on linear regression models. We hypothesise that highly influential data pairs are those when Di is larger than one, as suggested by Cook and Weisberg (1982). Their effect on local calibration regression equations (i) is shown. We also quantify the impact of potentially influential samples on monthly and event-scale mean TP concentration estimates produced with in situ sensors. In addition, we use multiple linear regression (SPSS 23.0) to test the effect of adding the TDP concentration as an additional explanatory variable to the local TP calibration equations.

Results

The quality and applicability of TP and PP estimates of the in situ turbidity sensors

The local TP, PP and turbidity calibration results are shown in Tables 2 and 3 and in the Supplementary material (Fig. A2). The median RPD between turbidity estimates of the sensors and laboratory analysed turbidity varied between 22 and 29% depending on the site considered (Table 3). Hence, there was not a perfect fit between the sensor and laboratory-determined turbidity. Thus, we used the quality-checked sensor raw turbidity and not the calibrated sensor turbidity in the formation of the local TP and PP calibration equation to avoid the potential additional imprecision between the two different turbidity determination methods.

Table 2 Determined regression models were used in local calibration to convert in situ sensor raw turbidity values into calibrated total phosphorus (TP), particulate phosphorus (PP) and turbidity (TURB) estimates. The explanatory variable (x) is the raw sensor turbidity. Summary statistics include the number of discrete data pairs (n), the maximum Cook’s distance (Di), the standard error (SE) of the slope, the coefficient of determination (R2), the root mean square error (RMSE), the model standard percentage error (MSPE) and the median relative percentage difference (RPD)
Table 3 The local calibration equations of the sensors without potentially influential data pairs for total phosphorus (TP), particulate phosphorus (PP) and turbidity (TURB). The explanatory variable (x) is the raw sensor turbidity

The Aurajoki River

The water sampling represented the discharge range and variation quite well between 2010 and 2013, i.e., during sensor deployment. However, the TP concentration range (48–670 μg L−1) (Fig. 1) was not as wide as the range (48–1300 μg L−1) from 1990 to 2017. However, laboratory data displayed similar regressions between TP and turbidity during the two monitoring periods (Fig. A3). There was only a minor difference in the mean ± standard error of the regression slopes (1.34 ± 0.04) of the sensor period data vs. 1.25 ± 0.02 of the long-term data, and the regression intercepts (64.29 ± 3.33 vs. 67.86 ± 2.11) were the same between the two periods. This indicates that the local TP calibration equation of the sensor can be applied to an extended concentration range of TP up to 1300 μg L−1. Overall, the sensor showed a slightly better capability to produce PP than TP estimates based on the R2, MSPE and median RPD (Table 3). Consistently, the median RPD of laboratory-based PP estimates was 13–14%, whereas for TP, it was 14–15%, but the MSPE values for PP were not better than those for TP (Table 4). However, there was a large variation between individual chemistry TP samples and TP estimates (Fig. 1), which was also the case for PP.

Fig. 1
figure 1

In situ sensor-based total phosphorus (TP) concentration estimates versus TP determined in the laboratory. The TP laboratory data that are considered potentially influential are marked with dashed circles. The TP estimates are calculated with the calibration equations given in Table 2

Table 4 Turbidity as an explanatory variable (x) for total phosphorus (TP) and particulate phosphorus (PP) in linear regression models based on water sampling and laboratory analyses. The correlation coefficient (R2), the root mean squared error (RMSE) of the regression model, the model standard percentage error (MSPE) and the median relative percentage difference (RPD) are also presented

The Savijoki River

The TP concentration range of the discrete samples was 64–1100 μg L˗1 during sensor deployment (Table 2). However, the majority of the samples only covered the TP range of 64–400 μg L˗1 (n = 135). The visual comparison of TP estimates and chemistry TP data (Fig. 1) and a large Di indicate that the calibration equation shown in Table 2 needs to be evaluated against an optional regression curve. MSPE (39%) and the median RPD (26%) were relatively large. The mean difference between chemistry data and sensor-based TP estimates was 47 μg L˗1 (SD = 44 μg L˗1).

The sensor deployment period (2009–2013, n = 140) and the long-term laboratory data (1990–2017, n = 919) resulted in notably different linear regressions between turbidity and TP (Fig. A3), which also indicates that the number of high TP concentration (> 400 μg L˗1) samples was low in the formation of the calibration equation. Only eight PP samples were available for the sensor calibration; thus, a PP estimation model was not produced for Savijoki.

Overall, the mean turbidity was similar in Savijoki and Aurajoki (Table 2 and Fig. A1). The sensor-measured turbidity in the Aurajoki main river was better than that in the Savijoki headwater based on MSPE and median RPD. However, the median difference between laboratory- and sensor-based turbidity was quite similar, with 9 FNU and 10 FNU in Aurajoki and Savijoki, respectively.

The Eurajoki River

The TP concentration of the discrete samples in the local sensor calibration ranged from 10 to 300 μg L˗1, but above the concentration 120 μg L˗1, only two samples were available (Fig. 1). Note that discrete samples prior to sensor deployment were not available from the Eurajoki sensor location. The median RPD values of the TP and PP estimates were 21% and 22% (Table 2), respectively, whereas the median absolute difference was 9 μg L−1 and 8 μg L−1 for TP and PP, respectively. The median RPD of 29% for the turbidity estimates was larger than that of the TP or PP. However, the turbidity level (mean: 13 FNU) was clearly lower in Eurajoki than at Sites 1 and 2. The mean difference between the sensor and laboratory-based turbidity was only 3.7 FNU (SD = 3.0 FNU).

The Yläneenjoki River

The median RPD was 30–31% for all water quality constituents, as one potentially influential point with high Di was within the regression and resulted in high R2 values (Table 2). The influential sample collected on May 20, 2014, had the highest TP concentration of 1400 μg L−1 and a turbidity value of 1100 FNU (Fig. 1). The rest of the discrete TP sample concentrations only reached 300 μg L˗1, and turbidity reached 120 FNU. An analysis of the constituent relationships without the influential sample is needed, and those equations are shown in Table 3.

The long-term laboratory data (1990–2017, n = 602) showed a rather similar regression between TP and TURB than the shorter sensor deployment period laboratory data (n = 35) due to the abovementioned sample with a high TP concentration (Fig. A3). Exclusion of that point from the long-term TP estimation model resulted in the following model: TP = 1.08 TURBlab + 73.8 (R2 = 0.49, n = 601, p < 0.001). However, the exclusion of the point did not introduce a significant change between the regressions (n = 602 and n = 601) shown in Table 4, since there were no differences in the mean ± standard error of the slopes and the intercepts. The equation (n = 601) was formed with data containing seven samples in the TP range 300–480 μg L˗1, which was not covered by the sensor calibration data. Exclusion of the potentially influential point from the laboratory data covering the period 2013–2015 resulted in the regression equation: TP = 0.98 TURBlab + 97.5 (R2 = 0.30, n = 34, p = 0.001). Thus, the strength of the relationship between TP and turbidity is quite low in terms of R2. There was no difference in the mean ± standard error of the regression slopes (0.98 ± 0.27) of the sensor period data vs. 1.08 ± 0.05 of the long-term data, but the regression intercept (97.5 ± 13.4 vs. 73.8 ± 2.3) differed slightly between the two datasets. Hence, extrapolation of the sensor TP calibration equation (Table 3) beyond the TP concentration of 300 μg L˗1 should be made with caution.

Turbidity as a surrogate for TP and PP based on discrete water sample data

The correlation of TP or PP with turbidity was significant (rs = 0.38–0.85, p < 0.001) at all sites, but the strength varied. TP had a similar correlation with turbidity in Aurajoki (rs = 0.85, n = 726) and Eurajoki (rs = 0.73, n = 108). In addition, the PP correlation in Aurajoki (rs = 0.85, n = 622) and Eurajoki (rs = 0.84, n = 102) was similar. In Savijoki, PP (rs = 0.45, n = 41) correlated less with turbidity than TP (rs = 0.81, n = 919), whereas in Yläneenjoki, the correlation of PP (rs = 0.54, n = 540) with turbidity was stronger than that of TP (rs = 0.38, n = 602). Thus, in all but one site, PP correlated equally or better than TP with turbidity. The mean TP/TURB ratios and standard deviation (SD) were 2.6 (SD = 1.4) in Aurajoki, 2.5 (SD = 3.1) in Savijoki, 5.0 (SD = 2.1) in Eurajoki and 5.0 (SD = 5.3) in Yläneenjoki. Thus, for the TP/TURB and PP/TURB ratios, the variance was larger in the sub-catchments compared with the larger catchment sites.

Linear regression models were fitted to all long-term discrete water samples, and additional models were formed by excluding points with Di > 1 (Table 4 and Fig. A3). In terms of R2, the relationship between PP and turbidity was better than that between TP and turbidity at three sites: Aurajoki, Eurajoki and Yläneenjoki (Table 4). However, according to the MSPEs, turbidity is not a better surrogate for PP than for TP. The median RPD of the TP estimates ranged from 14 to 23%, whereas for PP, the median RPD ranged from 13 to 38%. The median RPD value of the Savijoki PP estimate was high compared with that of other sites.

There was a notable deficiency in the quality of the TP or PP estimates at the minimum concentrations and at low concentrations when the largest RPDs were found. Thus, the lowest P estimates were systematically larger compared with the minimum P chemistry values (Table 4). The constants of the regression models determine the minimum P estimates, and those were always well above the minimum P concentrations based on chemistry analyses. Both under- and overestimation of the maximum concentrations occurred, and the match between discrete and estimated high P concentrations was highly dependent on the slope of the regressions. The difference between the maximum laboratory-determined TP concentrations and the estimated TP concentrations varied from ˗32 to 34%. The PP models estimated the maximum PP values with a difference ranging from ˗32 to 6%.

We calculated monthly TP estimates and recognized seasonal variation in monthly RPD values. On a monthly basis, the median RPDs of the TP model of Aurajoki varied between 8 and 22%. The highest median RPDs that appeared in April and May were 22% and 20%, respectively. Similarly, at other sites, the median RPD of TP estimation models was elevated during the spring months of April and May compared with other seasons (Fig. 2).

Fig. 2
figure 2

The relative percentage difference (RPD) between total phosphorus (TP) laboratory concentrations and TP estimates produced with linear regression models (see Table 4). The vertical lines within the boxes are the median

Potentially influential water samples

Visual inspection of the regressions between explanatory raw sensor data and chemistry TP and PP data indicates some potentially influential points, which if removed from or included in the regression may introduce a difference in the local sensor calibration and generated concentration estimates (Figs. 1 and A2). The hypothesis is that if Di > 1, it indicates a highly influential point. We evaluated the effect of a few high TP and PP concentrations as well as points with Di > 1 in local calibration models.

The Aurajoki TP estimation model had no data with Di > 1. The removal of the two points with the highest TP concentrations had a slight impact on the slope and intercept of the local calibration equation (Tables 2 and 3) and introduced an average difference of 13 μg L−1 (11%) in the monthly mean TP estimates between the two models (n = 125 and n = 123) (Fig. 3). However, the removal of the two high TP points increased the maximum Di, and two additional points were removed. This resulted in an average 7% difference only in monthly mean TP estimates between the original (n = 125) and the optional model (n = 121), and the difference was less than 10% during 30 months out of 45 (Fig. 3). The monthly mean TP concentration was the highest in December 2011, and the difference between the TP estimates was 6–14% (Fig. 3). The model (n = 121) had a better RMSE compared with the original but is technically applicable only at lower TP concentrations. Thus, we recommended applying the original TP model for Aurajoki. Exclusion of one point from the local PP calibration in Aurajoki resulted in an average 2% effect on monthly PP estimates. The effect size was 5–7% when the monthly PP concentration was large (> 270 μg L−1). Despite the minor effect of the point on the regression, we suggest removing it from the regression, since the PP concentration (95 μg L−1) of the point is low and it seems a true outlier based on visual analysis (Fig. A2). However, we decided to keep the two high PP values considered potentially influential points in the PP calibration. Their exclusion does not change the regression slope when the standard error of the estimate is taken into account or notably improves the error statistic of the local calibration, but they provide information about the PP and turbidity relationship at high PP concentrations.

Fig. 3
figure 3

The monthly mean sensor-based calibrated total phosphorus (TP) concentrations. The local calibration results are shown with and without potentially influential data for a Aurajoki, b Savijoki and c Eurajoki

In Savijoki, four points were considered potentially influential (Fig. 1), and after removal of those from the local calibration, Di improved notably (Tables 2 and 3). Two of those samples were collected on the same day, 7 October 2009. The first sample (TURB = 1300 FNU, TP = 1100 μg L˗1) was collected prior to the peak flow of a discharge event, and the second sample (TURB = 690 FNU, TP = 390 μg L˗1) was collected during the falling limb of the flow hydrograph. The two other potentially influential samples were collected in November 2011 and August 2009. A calibration model (n = 134) without potentially influential data covered the TP concentration range 64–400 μg L˗1 very well. The exclusion of potentially influential data improved the median RDP value from 26 to 24%. However, this introduced a large difference in estimated TP concentrations during high discharge episodes that typically appear during autumn or spring snowmelt (Fig. 4). The difference in the monthly mean TP estimates between the models was 20–24% during June–August 2010 and December 2011 (Fig. 4). The maximum effect of the points on the monthly TP estimate reached 64 μg L˗1 (20%) in December 2011. However, during 70% of the months, the difference was less than 10%. Based on the analysis, the variation in the relationship between turbidity and TP is large, and optional calibrations indicate that at high TP concentrations, the uncertainty of estimates is quite high.

Fig. 4
figure 4

Total phosphorus (TP) concentration based on grab samples and sensor estimates with two calibration curves at a Savijoki and b Eurajoki

In Eurajoki, the two discrete samples with the highest TP concentrations were considered potentially influential (Fig. 1). The sample with the highest TP concentration (300 μg L−1) was collected at the time of the rising limb of the hydrograph of a large snowmelt event that lasted for 10 days from 12 to 22 April 2013 and contributed 18% of the annual discharge volume. The mean estimated TP concentrations of that snowmelt event decreased 17% from 204 μg L˗1 (model n = 104; Fig. A4) to 170 μg L˗1 (model n = 103) by exclusion of that point with the highest TP from the local calibration. Removal of the two influential points one by one improved the median RPD of the TP estimates from 21% (n = 104) to 16% (n = 103) and to 15% (n = 102). The effect of the optional calibrations on monthly mean TP estimates reached 24 μg L˗1 (19%) (Fig. 3). The mean TP concentration was the highest in October 2012, and the related TP estimate was 127 μg L˗1 (n = 104), 109 μg L˗1 (n = 103) and 102 μg L˗1 (n = 102). However, in most months, the influential points had a relatively small effect (< 10%) on the mean TP estimates (Fig. 3). In the case of PP, the removal of one point from the local calibration improved the model as the median RDP decreased from 22 to 19% (Tables 2 and 3). However, the new model is strictly only applicable up to a PP concentration of 157 μg L˗1, which means that PP concentration estimates in high flow situations are highly uncertain.

For Yläneenjoki, removal of the TP sample with the highest concentration (1400 μg L ˗1) (Fig. 1) increased the mean slope of the calibration curve from 1.6 to 3.4, and the median RDP improved notably. The effect of influential data removal was similar for the PP calibration (Tables 2 and 3). Overall, we can state that more sampling at higher flow rates is needed to improve the sensor calibration.

Transferability of local sensor calibration between sites

The local TP calibration equations of the Aurajoki main river were transferred to its tributary, the Savijoki River (Fig. 5). Naturally, the Savijoki River, which is smaller, has steeper flow slopes and concentration changes than the main river. The transferred equations seem to function as a mean TP calibration for the Savijoki sensor, since those fit in between the local sensor calibration equations of the Savijoki site (Fig. 5). There was a small difference only in the mean ± standard error of the regression slopes between the two study sites, of 2.73 ± 0.122 at Aurajoki vs. 2.28 ± 0.107 at Savijoki, whereas the regression intercepts were the same when all data were included in regressions (Table 2). There were no differences in regression slopes between Aurajoki (3.038 ± 0.163) and Savijoki (3.31 ± 0.250) when the potentially influential points were removed from the regressions (Table 3). Hence, the data suggest that calibration of Aurajoki could be transferred to Savijoki.

Fig. 5
figure 5

Relationship between raw turbidity (TURBraw) sensor values and total phosphorus (TP). The dots are TP grab samples at Savijoki. White dots indicate potentially influential data. The black lines denote TP estimates based on two optional local sensor TP calibration models for Savijoki. The grey lines represent TP estimates based on the local sensor calibration models of the Aurajoki River, which is the headwater of the Savijoki River. The dashed lines denote TP estimates as potentially influential points are excluded from the sensor calibrations

The impact of TDP on the surrogate relationship between turbidity and TP based on grab samples

The applicability of turbidity as a proxy for TP may decrease in the case of large temporary variability in the TDP/TP ratio. The mean TDP/TP ratio and SD were slightly higher in the sub-catchment sites (Savijoki [0.29, SD = 0.17] and Yläneenjoki [0.32, SD = 0.14]) compared with the larger basins (Aurajoki [0.25, SD = 0.12] and Eurajoki [0.26, SD = 0.12]). The discrete samples indicated that at high turbidity levels, the TDP/TP ratio remained low (< 0.2; Fig. A4). Accordingly, the mean and median TDP/TP ratios were the largest at each site during winter (Jan.–Mar.) when these rivers freeze and the river discharges are typically low. Thus, the TDP/TP ratio showed some seasonal variation. Despite the mean TDP/TP ratios being elevated in winter, the RPD of the TP estimates was not higher during the winter months January–March compared with other seasons (Fig. 2). Seasonally, the lowest mean and median TDP/TP ratios were found either during summer (for Aurajoki), autumn (for Savijoki), or spring (for Eurajoki and Yläneenjoki).

We tested the impact of the varying TDP/TP ratio on the relationship between TP and turbidity at TP concentrations lower than 400 μg L−1 by splitting the grab sample data of Aurajoki into three subsets according to the level of the TDP/TP ratio (Fig. 6). The data belonging to the subgroup TDP/TP > 0.31 represented 20% of the data. The related regression model produced up to 30% higher TP concentration estimates than the model based on all data (Table 4). Eighty percent of the observations, at TP concentrations lower than 400 μg L−1, belonged to the two other groups where the TDP/TP ratio was lower and the linear TP estimation models differed notably (Fig. 6). Thus, the episodically varying TDP/TP ratio has a great impact on the accuracy of some of the TP estimates. More precisely, the results suggest that linear models underestimate the actual TP concentration episodically when the TDP/TP ratio is high.

Fig. 6
figure 6

Relationship between turbidity (TURB) and total phosphorus (TP) based on grab samples collected from the Aurajoki River. The data were divided into three groups based on the ratio between total dissolved phosphorus and total phosphorus (the TDP/TP ratio). Linear regression models between TP and TURB are shown for the three groups. The difference between the model-predicted TPs increased as turbidity increased. The p values of the analyses were less than 0.001

TDP as an additional explanatory variable in TP estimation

The addition of TDP as an explanatory variable to the local TP calibration of the in situ sensors could potentially improve the TP estimation models. Multiple linear TP estimation models were built for Sites 1, 3 and 4 (Table A3) since TDP data were not available for Savijoki. Analysis indicated the absence of multicollinearity between TDP and raw turbidity since the correlation between the predictors was less than 0.7 at all sites. The R2, RMSE and MSPE of TP estimation improved at all three sites. Median RPDs were 12%, 15% and 12% for Sites 1, 3 and 4, respectively. This indicates that the addition of TDP to local calibration improved the TP estimates notably at the Aurajoki and Yläneenjoki sites, but for Eurajoki, the median RPD remained similar.

Discussion

We calculated TP and PP concentration estimates with turbidity as a proxy. The differences in the error statistics (MSPE, median RPD) between the TP and PP estimates were small. This indicates that turbidity is an equal proxy for both PP and TP concentrations in rivers draining catchments typified by Vertical Cambisol, Haplic Podzol and Lithic Leptosol soils. The local sensor calibrations resulted in a median RPD of 15–24% for TP and 15–19% for PP at the studied sites. These values were found when the influential samples were removed, which may reduce the applicability of the sensors in producing reliable enough estimates at high P concentrations. Earlier, Christensen et al. (2002) reported median RPD ranging from 10 to 17% for TP estimates in four Kansas streams. Their results were based on only 1 year of data. It is obvious that our data are more comprehensive, including a wider range of natural water quality variations as well as multiyear sensor and laboratory data. The calculated error statistics in our case indicate a slightly lower performance level of the surrogate equations, potentially because of the larger range of water quality variation described by our more extensive amount of monitoring data. The MSPE values of the TP surrogate equations for the larger and smaller watersheds were 25% and 29–35%, respectively. These values are similar to the TP surrogate equation results presented by Spackman Jones et al. (2011), which showed an MSPE of 26–35% for two sites in the Little Bear River in the USA. Overall, sensor raw turbidity functioned better as a proxy for TP and PP for the two larger rivers compared with their sub-catchments. The TDP/TP ratio was higher and had a larger variation in the sub-catchment sites. In addition, the TP/TURB and PP/TURB ratios had a larger variance in the sub-catchment sites compared with the larger ones. These variations are likely to at least partly explain the better performance of the TP and PP estimation models for the larger rivers, which is consistent with the findings of Spackman Jones et al. (2011). We assumed that the sensors would provide better estimates for PP than TP due to light scattering properties of particles carrying PP. The relationship between in situ measured turbidity and PP was slightly stronger than that between turbidity and TP, although MSPE indicated varying results for turbidity as a surrogate for PP and TP.

We used long-term laboratory data parallel to the short-term laboratory data collected during the deployment of the sensors. This proved beneficial in the analysis of the quality and applicability of the local sensor calibrations. We found long-term data (provided by the national surface water quality monitoring programme) useful since the data included additional high flow events associated with high turbidity values and P concentrations, which were rarely captured during sensor deployment despite intentions to collect samples at high flows. Aurajoki’s long-term data included a decent number of samples that covered large turbidity and TP ranges. The TP concentration estimates based on the long-term and shorter sensor deployment period discrete samples showed similar regression equations for Aurajoki. Thus, the Aurajoki local sensor calibration equation was found to be applicable to a larger P concentration range than the range of the discrete samples used for the sensor calibration.

The median RPD of the TP estimates, based on long-term discrete samples, was between 14 and 23% (n = 106–919) depending on the site considered. These values were on the same level as those for the sensor-estimated TP concentrations. We compared individual sample pairs (in situ measurement and discrete water samples) and water quality concentrations produced with different instruments; thus, part of the calculated difference is due to the difference between the samples and analysis methods. The overall performance level of the turbidity sensors with regard to producing high-frequency TP and PP estimates seems acceptable when keeping in mind that many sources of uncertainties are also involved in water sampling and laboratory analyses. In general, the acceptable measurement uncertainty is ± 20% for turbidity and ± 15% for TP and PP laboratory data, which are available at lower frequencies, and sampling is often lacking during short-term storm events. The high frequency in situ monitoring provides an extensive amount of data on the turbidity variation, but a linear relationship between turbidity and TP or PP does not fully explain the temporal variation in turbidity and P ratios that was present in the studied sites. This increases the uncertainty of TP and PP estimates based on turbidity sensor data. Thus, it is important to be aware of the strengths and limitations of proxy estimations and the applicability of TP and PP concentration estimates when evaluating catchment dynamics over different time scales.

A major portion of annual nutrient loading from diffuse sources takes place during autumn storms and spring snowmelt storms; thus, capturing P concentrations during these events is essential. Typically, water quality constituents respond in a different manner to flow changes at the rising and falling limbs of the flow hydrograph (Kämäri et al. 2018; Lloyd et al. 2016). Thus, hysteresis may have a notable effect on the local calibration of sensors and may introduce bias into P concentration estimates if turbidity is used as a proxy for P. In Eurajoki, we demonstrated a difference as large as 17% in the mean TP concentration estimates of a large snowmelt event based on two optional sensor calibration equations. This finding is consistent with the work of Minaudo et al. (2017), who reported that TP concentration estimates during high discharge episodes were subject to considerable uncertainty, dependent on the storm event considered, as they used a nonlinear model to convert turbidity into TP. A nonlinear empirical modelling approach with hysteresis effects included between TP and turbidity might improve the modelling result but would require intensive grab sampling and preferably use bankside analysers during several storms (Minaudo et al. 2017). At some sites, improvements to the linear surrogate measures could be achieved by employing spring snowmelt as a categorical explanatory variable according to Spackman Jones et al. (2011). Stutter et al. (2017) found differing calibration relationships between turbidity and PP at the rising and falling limbs of a storm event hydrograph but also found that the approach requires intensive water sample-based monitoring. Potentially, storm classification and turbidity sensor calibration based on storm type could improve the calibration results, as suggested by Stutter et al. (2017). The storm-type classification approach would require the multi-year intensive sampling of a large number of storms. It would be worth testing different river sizes, especially if such calibrations were transferable across catchments with similar soils and land use. To date, site-specific calibrations have been judged to be non-transferable between catchments (e.g., Stutter et al. 2017). However, our analysis suggested that the local TP calibration model is transferable between the main river and its tributary. It would be worth continuing testing if a common calibration curve could be reasonably applied to similar catchments.

The local calibrations shown could be improved by increasing the number of discrete samples collected during high flow events. It is recommended that an automated water sampler be applied since we showed that regular environmental monitoring rarely captures rapid high-concentration storm events. Potentially, separate calibrations for baseflow and stormflows could be developed in the future in case a larger amount of data clearly indicates a nonlinear relationship between turbidity and TP.

On a monthly basis, the highest median RPD values of the TP concentration estimates in the Aurajoki, Savijoki and Yläneenjoki catchments were found in April or May. The TP/TURB ratios were consistently relatively low in April and May. Accordingly, PP/TURB ratios were lower than average from April to May at each site, reflecting snowmelt and flow change impacts to some degree. In line with this, Stubblefield et al. (2007) reported a decreased ratio between TP and total suspended solids during increased spring flows. In an earlier study, Spackman Jones et al. (2011) found that the TP/TURB ratio varied between snowmelt and baseflow conditions and reported a categorical variable for spring snowmelt that was significant for TP estimates.

The lowest TP and PP concentrations were systematically overestimated by the sensors. The relatively large intercepts (13–90 μg L−1) of the linear TP regressions when compared with minimum laboratory concentrations were resulted in an overestimation of the lowest TP concentrations. Some earlier study results show relatively large intercepts in regression equations for TP estimates (e.g., Christensen et al. 2002), and Spackman Jones et al. (2011) reported a notable amount of TP concentration estimates below a detection limit. Thus, we suggest further studies on suitable solutions for handling low concentrations in relation to surrogate use in riverine in situ monitoring. In addition, the range of the TP/TURB ratio increased considerably during low turbidity conditions and introduced bias between TP estimates and discrete TP samples. However, the minimum P concentrations appeared during low flows; thus, the bias in low flow P estimates likely does not have a considerable impact on annual P load estimates.

The extensive long-term laboratory data only showed a moderate correlation (rs = 0.4) between turbidity and TP in Yläneenjoki. Seasonal catchment dynamics and land-use practices introduced the most pronounced temporal variation in the TP/TURB ratio since, from June to the end of October, the mean TP/TURB ratio (mean = 8.1, SD = 6.9) was more than two times higher than the mean of November–May (mean = 3.1, SD = 2.7). The Yläneenjoki catchment has more poultry than the other sites, and chicken manure is applied to fields in spring. This may have potentially contributed to the occasionally highly elevated TP/TURB ratios found during summer and early autumn. Overall, the TP/TURB ratio was more stable in Aurajoki and Eurajoki than in Savijoki and Yläneenjoki.

The influential samples had a varying impact on the TP estimates. During autumnal high flows or spring snowmelt events, the mean TP concentrations were notably different, depending on the selected sensor calibration model. Thus, the performance of turbidity sensors in estimating the TP concentration is questionable, despite the high measurement frequency, if the temporal variation in the TP and turbidity ratio is not captured well enough with local TP estimation models at high flow events that contribute a large share of annual nutrient fluxes. A large Di in regression does not automatically mean exclusion of a point from the regression, but additional evaluation of the point’s influence on the regression slope and intercept is needed.

The median TDP/TP ratio was the highest at each site during the winter season, but we were not able to generate a seasonally different relationship between turbidity and TP since the variation in the TDP/TP ratio was also large within seasons. Thus, short-term variation in the TDP/TP ratio caused inaccuracy in the TP estimates generated with the turbidity surrogate. This result is in line with that presented by Lannergård et al. (2019), who found that season was not a significant factor in the relationship between high-frequency turbidity and TP. The addition of discharge as an additional explanatory variable for the P estimation model might improve TP estimation at some sites. Minaudo et al. (2017) used discharge as a proxy of reactive P.

Variation in the TP/TURB and TDP/TP ratios caused inaccuracy to the performance of the linear P regression models, which is partly related to hydrological conditions. These observed variations likely also reflected local land-use practices and temporal shifts in the transportation pathways of TP compared with turbid matter; in addition, these variations likely reflected the origin of the operational P fractions observed in river water. For example, the organic matter content of turbid matter impacts P concentrations. P-rich organic matter and fine sediments typically accumulate within the reach during low flows and have been reported to mobilise during high flow conditions (Evans et al. 2004). The slope of the linear regression model between laboratory-determined TP and turbidity was the highest as the TDP/TP ratio was large in the Aurajoki site. The result indicates that periodically, part of P was transported in a form that does not scatter light and was not detectable with the nephelometric method. We observed that the addition of TDP to the TP regression model as an additional explanatory variable improved the regression. Schilling et al. (2017) concluded that in some rivers, the inclusion of orthophosphorus in the TP regression model was less important, but at other sites, it was critically important. However, it is not possible to measure TDP continuously with a UV-Vis probe, which hampers the usability of TDP in the conversion of in situ sensor data into TP estimates. Of the future developments, perhaps, the best approach would be to have a high-frequency P device that can directly measure the P concentration of water in the field. Until then, however, there is still a need to investigate the TP/TURB ratio in waters with varying TDP concentrations. Further studies should focus on stormflow events when the nutrient load is at its highest.

Conclusions

This study analyses how well TP and PP concentrations can be captured with in situ high-frequency UV-Vis turbidity sensors in rivers draining clay-dominated catchments where TP and PP correlate with turbidity to varying degrees. We found that turbidity is an equally good proxy for PP and TP. Thus, the error statistics of PP and TP estimates were quite similar. The median difference between the discrete P samples and the high-frequency P estimates ranged from 15 to 24% depending on the site considered. We presented the challenges that are faced in the use of sensor turbidity as a proxy for P in practice. Local sensor calibration is a crucial point in cases where surrogates are used. Preferably, a large number of discrete samples covering the entire range and variation in turbidity and P concentration are needed, but in practice, high flow events are rarely sampled without an automated sampler. In addition, linear regression and turbidity as a surrogate for P may introduce a large bias, even in annual P load estimates when large flow events comprise a considerable share of annual water yield. We quantified that optional sensor calibrations (i.e., with and without influential samples) introduced a 17% difference into estimated mean TP concentrations during a snowmelt storm. However, for most months, influential samples accounted for less than a 10% difference in the monthly mean TP concentration estimates between two optional calibrations. To overcome the lack of discrete samples with high P concentrations during sensor deployment, we additionally analysed the relationship between turbidity and P based on long-term discrete sampling (1990–2017). We showed that the analyses of long-term data in parallel with short-term in situ monitoring period data are useful since they may, on the one hand, show an increased applicability range of sensor calibrations or, on the other hand, suggest that more sampling is needed for sensor calibration. This approach is recommended as a common practice in local in situ sensor calibration.

The data suggested that linear regressions between TP or PP and turbidity do not fully describe actual TP and PP concentrations in the rivers. A large seasonal variation in the relationship between turbidity and P values, the hysteresis effect and the variation in the TDP/TP ratio decreased the performance of the regression models. The RPD between discrete TP and PP samples and estimated samples was large, especially at low concentrations, since the constants of the calibration equations that determine the minimum concentration of P estimates were larger than the minimum laboratory-based P concentrations. The removal of influential observations improved the overall performance of the regression models, but simultaneously, the representativeness of calibrations at the highest TP or PP concentrations became uncertain. A large share of the annual P load takes place during relatively short-term runoff events during snowmelt and autumn; thus, it is crucial to accurately estimate the high P concentrations during these events. In the case where the regression model does not adequately describe the high concentrations during high flow events, the uncertainty of annual load estimates may become unacceptable.

We recommend analysing the correlation and regressions of turbidity with P based on intensive laboratory analyses before investing in a turbidity sensor for the purpose of monitoring the P concentration in rivers. More research is needed to define better and cost-effective surrogate calibration methods that could be applied in national water quality monitoring programmes. Research-based discussion on the acceptable uncertainty of event-scale estimates, annual nutrient concentration estimates or load estimates is also encouraged.