Hostname: page-component-8448b6f56d-t5pn6 Total loading time: 0 Render date: 2024-04-19T22:12:34.106Z Has data issue: false hasContentIssue false

Small Péclet-number mass transport to a finite strip: An advection–diffusion–reaction model of surface-based biosensors

Published online by Cambridge University Press:  05 September 2019

EHUD YARIV*
Affiliation:
Department of Mathematics, Technion – Israel Institute of Technology, Haifa32000, Israel email: yarivehud@gmail.com

Abstract

We consider two-dimensional mass transport to a finite absorbing strip in a uniform shear flow as a model of surface-based biosensors. The quantity of interest is the Sherwood number Sh, namely the dimensionless net flux onto the strip. Considering early-time absorption, it is a function of the Péclet number Pe and the Damköhler number Da, which, respectively, represent the characteristic magnitude of advection and reaction relative to diffusion. With a view towards modelling nanoscale biosensors, we consider the limit Pe«1. This singular limit is handled using matched asymptotic expansions, with an inner region on the scale of the strip, where mass transport is diffusively dominated, and an outer region at distances that scale as Pe-1/2, where advection enters the dominant balance. At the inner region, the mass concentration possesses a point-sink behaviour at large distances, proportional to Sh. A rescaled concentration, normalised using that number, thus possesses a universal logarithmic divergence; its leading-order correction represents a uniform background concentration. At the outer region, where advection by the shear flow enters the leading-order balance, the strip appears as a point singularity. Asymptotic matching with the concentration field in that region provides the Sherwood number as

$${\rm{Sh}} = {\pi \over {\ln (2/{\rm{P}}{{\rm{e}}^{1/2}}) + 1.0559 + \beta }},$$
wherein β is the background concentration. The latter is determined by the solution of the canonical problem governing the rescaled inner concentration, and is accordingly a function of Da alone. Using elliptic-cylinder coordinates, we have obtained an exact solution of the canonical problem, valid for arbitrary values of Da. It is supplemented by approximate solutions for both small and large Da values, representing the respective limits of reaction- and transport-limited conditions.

Type
Papers
Copyright
© Cambridge University Press 2019

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

This work was supported by the Israel Science Foundation (Grant No. 1081/16).

References

Ackerberg, R. C., Patel, R. D. & Gupta, S. K. (1978) The heat/mass transfer to a finite strip at small Péclet numbers. J. Fluid Mech. 86, 49.CrossRefGoogle Scholar
Bender, C. M. & Orszag, S. A. (1978) Advanced Mathematical Methods for Scientists and Engineers, McGraw-Hill, New York.Google Scholar
Bretherton, F. P. (1962) Slow viscous motion round a cylinder in a simple shear. J. Fluid Mech. 12, 591.CrossRefGoogle Scholar
Bunimovich, Y. L., Shin, Y. S., Yeo, W.-S., Amori, M., Kwong, G. & Heath, J. R. (2006) Quantitative real-time measurements of DNA hybridization with alkylated nonoxidized silicon nanowires in electrolyte solution. J. Am. Chem. Soc. 128, 16323.CrossRefGoogle ScholarPubMed
Cui, Y., Wei, Q., Park, H. & Lieber, C. M. (2001) Nanowire nanosensors for highly sensitive and selective detection of biological and chemical species. Science 293, 1289.CrossRefGoogle ScholarPubMed
Ebbens, S., Tu, M.-H., Howse, J. R. & Golestanian, R. (2012) Size dependence of the propulsion velocity for catalytic Janus-sphere swimmers. Phys. Rev. E 85, 020401.CrossRefGoogle ScholarPubMed
Frankel, N. A. & Acrivos, A. (1968) Heat and mass transfer from small spheres and cylinders freely suspended in shear flow. Phys. Fluids 11, 1913.CrossRefGoogle Scholar
Hinch, E. J. (1991) Perturbation Methods, Cambridge University Press, Cambridge.CrossRefGoogle Scholar
Johnsson, B., Löfås, S. & Lindquist, G. (1991) Immobilization of proteins to a carboxymethyldextran-modified gold surface for biospecific interaction analysis in surface plasmon resonance sensors. Anal. Biochem. 198, 268.CrossRefGoogle ScholarPubMed
Kaplun, S. (1957) Low Reynolds number flow past a circular cylinder. J. Math. Mech. 6, 595.Google Scholar
Kropinski, M. C. A., Ward, M. J. & Keller, J. B. (1995) A hybrid asymptotic-numerical method for low Reynolds number flows past a cylindrical body. SIAM J. Appl. Math . 55, 1484 (1995).CrossRefGoogle Scholar
Leal, L. G. (2007) Advanced Transport Phenomena: Fluid Mechanics and Convective Transport Processes, Cambridge University Press, New York.CrossRefGoogle Scholar
Michelin, S. & Lauga, E. (2014) Phoretic self-propulsion at finite Péclet numbers. J. Fluid Mech. 747, 572.CrossRefGoogle Scholar
Moon, P. & Spencer, D. E. (1988) Field Theory Handbook. Springer-Verlag, New York.Google Scholar
Proudman, I. & Pearson, J. R. A. (1957) Expansions at small Reynolds numbers for the flow past a sphere and a circular cylinder. J. Fluid Mech. 2, 237.CrossRefGoogle Scholar
Sheehan, P. E. & Whitman, L. J. (2005) Detection limits for nanoscale biosensors. Nano Lett . 5, 803.CrossRefGoogle ScholarPubMed
Squires, T. M., Messinger, R. J. & Manalis, S. R. (2008) Making it stick: convection, reaction and diffusion in surface-based biosensors. Nat. Biotechnol. 26, 417.CrossRefGoogle ScholarPubMed
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M. & Reed, M. A. (2007) Label-free immunodetection with CMOS-compatible semiconducting nanowires. Nature 445, 519.CrossRefGoogle ScholarPubMed
Titcombe, M. S. & Ward, M. J. (1997) Convective heat transfer past small cylindrical bodies. Stud. Appl. Math. 99, 81.CrossRefGoogle Scholar
Van Dyke, M. (1964) Perturbation Methods in Fluid Mechanics. Academic Press, New York.Google Scholar
Yariv, E. (2016) Wall-induced self-diffusiophoresis of active isotropic colloids. Phys. Rev. Fluids 1, 032101.CrossRefGoogle Scholar
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U. & Lieber, C. M. (2005) Multiplexed electrical detection of cancer markers with nanowire sensor arrays. Nat. Biotechnol. 23, 1294.CrossRefGoogle ScholarPubMed