Investigation of Different Compression Apparatus Usage Effects in Calibration Process of Strain Cylinders

  • Original Paper
  • Published:
MAPAN Aims and scope Submit manuscript

Abstract

In this article, in calibration process of strain cylinder, which is performed according to ISO 376 standard, effect of loading apparatus with different dimensions on measurement result has been investigated. In addition, relative repeatability error of calibration on measurement results, temperature fluctuation, accuracy error of measurements, creep error, as well as the stability and metrological characteristics of indicator have been examined. As a result, it has been determined that use of loading pads with different diameters has significantly affected metrological performance of strain cylinder.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. BS EN 12390-4:2000, Testing Hardened Concrete, Part 4: Compressive Strength—Specification for Testing Machines.

  2. EN ISO 376:2011, Metallic Materials-Calibration of Force-proving Instruments Used for the Static Verification of Uniaxial Testing Machines.

  3. P. Averlant, Strain Cylinders for Compression Testing Machines, IMEKO TC3 Cairo, Egypt, 2005.

  4. J. Cui, R. Kumme and H. Kahmann, Proposal and Investigation of a New Method for Calibration of Strain Cylinders Using Laser Interferometry, IMEKO TC3 Helsinki Finland, 2017.

  5. GTM Measurement Amplifier LT Digitizer Technical Data Sheet, in English, 02/03/2015.

  6. B. Aydemir, H. Dizdar and C. Vatan, An Investigation and Calculation of Uncertainty in Calibration of Force-proving Instruments according to EN ISO 376 Standard, Force Laboratory Technical Document, TUBITAK UME, S.2, N.1, 2019 (1–11).

  7. B. Aydemir, H. Dizdar and C. Vatan, General force metrology training notes, TUBITAK UME Gebze-Kocaeli, 2017.

  8. B. Aydemir, Calibration of concrete test press training notes, TUBITAK UME Gebze-Kocaeli, 2011.

  9. EURAMET cg-04, Guide document, uncertainty of force measurements, 2011.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Haldun Dİzdar.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Dİzdar, H., Aydemİr, B. & Vatan, C. Investigation of Different Compression Apparatus Usage Effects in Calibration Process of Strain Cylinders. MAPAN 35, 359–364 (2020). https://doi.org/10.1007/s12647-020-00375-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12647-020-00375-4

Keywords

Navigation