The advent of X-pinch based compact radiographs has significantly expanded the application field of pulsed radiography for diagnostics of fast processes. The key point here is the spatial resolution which these radiographs can provide. The method for determining the size of the soft x-ray (SXR) source based on diffraction imaging of opaque metallic wires and their comparison with the diffraction pattern calculated for an extended source in a given spectral range is presented in the paper. The X-pinch source sizes have been measured taking into account the sensitometric characteristic of the film and the scanner characteristics. By this method it has been shown that the diameter of the X-pinch radiation source for current rise rates in the range 0.7–1.35 kA/ns varies slightly for the spectral range hv >3 keV.
Similar content being viewed by others
References
S. M. Zakharov, G. V. Ivanenkov, A. A. Kolomenskii, et al., Sov. Tech. Phys. Lett., 8, 1060–1063 (1982).
D. A. Hammer, D. H. Kalantar, K. C. Mittal, and N. Qi, Appl. Phys. Lett., 57, 2083–2085 (1990).
S. A. Pikuz, T. A. Shelkovenko, A. R. Mingaleev, et al., Proc. SPIE, 5974, 59740 (1–9) (2005).
A. P. Artyomov, A. V. Fedunin, S. A. Chaikovsky, and N. A. Ratakhin, J. Phys.: Conf. Series, 653, 012144 (1–5) (2015).
A. G. Rousskikh, A. V. Fedyunin, A. P. Artyomov, et al., Curr. Appl. Phys., 19, 704–708 (2019).
E. V. Parkevich, I. N. Tilikin, A. V. Agafonov, et al., JEТP Lett., 103, 357–361 (2016).
A. P. Artyomov, A. S. Zhigalin, I. V. Lavrinovich, et al., Instr. Exp. Tech., 57, No. 4, 461–474 (2014).
R. B. Baksht, A. G. Rousskikh, A. S. Zhigalin, et al., Phys. Plasmas, 22, 103521 (1–6) (2015).
F. N. Beg, R. B. Stephens, H. W. Xu, et al., Appl. Phys. Lett., 89, 101502 (1–3) (2006).
L. E. Aranchuk, A. S. Chuvatin, and J. Larour, Rev. Sci. Instrum., 75, 69–74 (2004).
S. A. Chaikovsky, A. P. Artyomov, N. V. Zharova, et al., Russ. Phys. J., 60, No. 8, 1408–1412 (2017).
N. A. Ratakhin, V. F. Fedushchak, A. A. Erfort, et al., Russ. Phys. J., 50, No. 2, 193–198 (2007).
S. A. Pikuz, T. Shelkovenko, and D. A. Hammer, Plasma Phys. Rep., 41, No. 4, 291–342 (2015).
E. I. Butikov, Optics [in Russian], Lan’, Saint Petersburg (2012).
A. N. Matveev, Optics [in Russian], Vysshaya Shkola, Moscow (1985).
M. Born and E. Wolf, Principles of Optics [Russian translation], Nauka, Moscow (1973).
E. Hech, Optics, Addison-Wesley, San Francisco (2002).
J. M. Cowley, Diffraction Physics, North-Holland, Amsterdam (1975).
V. Kohn, I. Snigireva, and A. Snigirev, Phys. Rev. Lett., 85, 2745–2748 (2000).
B. L. Henke, E. M. Gullikson, and J. C. Davis, At. Data Nucl. Data Tables, 54, 181–342 (1993).
M. A. Blokhin, Physics of X-Rays [in Russian], State Publishing House of Technical and Theoretical Literature, Moscow (1953).
P. Choi, C. Dumitrescu, E. Wyndham, et al., Rev. Sci. Instrum., 73, No. 6, 2276–2281 (2002).
B. M. Song, S. A. Pikuz, T. A. Shelkovenko, and D. A. Hammer, Appl. Opt., 44, 2349–2358 (2005).
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Izvestiya Vysshikh Uchebnykh Zavedenii, Fizika, No. 12, pp. 33–41, December, 2019.
Rights and permissions
About this article
Cite this article
Artyomov, A.P., Chaikovsky, S.A., Oreshkin, V.I. et al. On the Size of the Soft X-Ray Radiation Source Based on an X-Pinch. Russ Phys J 62, 2194–2203 (2020). https://doi.org/10.1007/s11182-020-01966-z
Received:
Revised:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11182-020-01966-z