Skip to main content
Log in

Soaking of autografts with vancomycin is highly effective on preventing postoperative septic arthritis in patients undergoing ACL reconstruction with hamstrings autografts

  • KNEE
  • Published:
Knee Surgery, Sports Traumatology, Arthroscopy Aims and scope

Abstract

Purpose

To evaluate the impact of local soaking of the autografts with vancomycin during anterior cruciate ligament (ACL) reconstruction on postoperative infection rates.

Methods

Between 2003 and 2014 (first study period), 1,242 patients underwent ACL reconstruction using autografts, without soaking them in vancomycin solution, while between 2014 and 2019 (second study period) all ACL autografts in 593 patients were soaked in a 5-mg/ml vancomycin solution, in a territory University Hospital. The same standard treatment of perioperative IV antibiotics was applied in both groups.

Results

Postoperative septic arthritis occurred in seven out of 1,242 patients (0.56%) during the first study period. Bone patellar tendon bone autograft was used in 311 (25%) patients, and hamstring tendon autograft was used in the rest 931 (75%) of the study population during this period. All infected cases were male and had a hamstrings graft implanted. There were no postoperative infections (0%) in 593 ACL reconstructions during the second study period. Bone patellar tendon bone autograft was used in 178 (30%) patients while hamstring tendon autograft was used in the rest 415 (70%) of the study population, during this period. Statistical analysis revealed a significantly reduced postoperative infection rate (p = 0.018) between the two reported periods, with the main impact referring to the use of hamstrings autograft (p = 0.031) for the first study period.

Conclusions

Septic arthritis following ACL reconstruction can be significantly reduced (or even eliminated) by soaking ACL autografts in a 5 mg/ml vancomycin solution. Of note, this strategy seems to be more effective in the setting of hamstring tendon autograft use, since the risk of postoperative knee infection is significantly higher when this type of graft is used.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1

Similar content being viewed by others

References

  1. Alomar AZ, Alfayez SM, Somily AM (2018) Hamstring autografts are associated with a high rate of contamination in anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 26:1357–1361

    Article  Google Scholar 

  2. Barker JU, Drakos MC, Maak TG, Warren RF, Williams RJ, Allen AA (2010) Effect of graft selection on the incidence of postoperative infection in anterior cruciate ligament reconstruction. Am J Sports Med 38:281–286

    Article  Google Scholar 

  3. Baron JE, Shamrock AG, Cates WT, Cates RA, An Q, Wolf BR, Bollier MJ, Duchman KR, Westermann RW (2019) Graft preparation with intraoperative vancomycin decreases infection after ACL reconstruction. J Bone Joint Surg 101:2187–2193

    Article  CAS  Google Scholar 

  4. Cadet ER, Makhni EC, Mehran N, Schulz BM (2013) Management of septic arthritis following anterior cruciate ligament reconstruction: a review of current practices and recommendations. J Am Acad Orthop Surg 21:647–656

    Article  Google Scholar 

  5. Grayson JE, Grant GD, Dukie S, Vertullo CJ (2011) The in vitro elution characteristics of vancomycin from tendons. Clin Orthop Relat Res 469:2948–2952

    Article  Google Scholar 

  6. Hantes ME, Basdekis GK, Varitimidis SE, Giotikas D, Petinaki E, Malizos KN (2008) Autograft contamination during preparation for anterior cruciate ligament reconstruction. J Bone Joint Surg Am 90:760–764

    Article  Google Scholar 

  7. Hantes ME, Raoulis VA, Doxariotis N, Drakos A, Karachalios T, Malizos KN (2017) Management of septic arthritis after arthroscopic anterior cruciate ligament reconstruction using a standard surgical protocol. Knee 24:588–593

    Article  Google Scholar 

  8. Indelli PF, Dillingham M, Fanton G, Schurman DJ (2002) Septic arthritis in postoperative anterior cruciate ligament reconstruction. Clin Orthop Relat Res 398:102–108

    Article  Google Scholar 

  9. Judd MAJD, Bottoni LTCC, Kim D, Burke CPTM, Hooker MAJS (2006) Infections following arthroscopic anterior cruciate ligament reconstruction. Arthroscopy 22:375–384

    Article  Google Scholar 

  10. Katz LM, Battaglia TC, Patino P, Reichmann W, Hunter DJ, Richmond JC (2008) A retrospective comparison of the incidence of bacterial infection following anterior cruciate ligament reconstruction with autograft versus allograft. Arthroscopy 24:1330–1335

    Article  Google Scholar 

  11. Lubowitz JH (2015) Editorial commentary: hamstring autografts are more frequently associated with ACL infection. Arthroscopy 31:1402

    Article  Google Scholar 

  12. Maletis GB, Inacio MCS, Reynolds S, Desmond JL, Maletis MM, Funahashi TT (2013) Incidence of postoperative anterior cruciate ligament reconstruction infections: graft choice makes a difference. Am J Sports Med 41:1780–1785

    Article  Google Scholar 

  13. McAllister DR, Parker RD, Cooper AE, Recht MP, Abate J (1999) Outcomes of postoperative septic arthritis after anterior cruciate ligament reconstruction. Am J Sports Med 27:562–570

    Article  CAS  Google Scholar 

  14. Offerhaus C, Balke M, Hente J, Gehling M, Blendl S, Höher J (2019) Vancomycin pre-soaking of the graft reduces postoperative infection rate without increasing risk of graft failure and arthrofibrosis in ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 27:3014–3021

    Article  Google Scholar 

  15. Pérez-Prieto D, Portillo ME, Torres-Claramunt R, Pelfort X, Hinarejos P, Monllau JC (2018) Contamination occurs during ACL graft harvesting and manipulation, but it can be easily eradicated. Knee Surg Sports Traumatol Arthrosc 26:558–562

    Article  Google Scholar 

  16. Pérez-Prieto D, Torres-Claramunt R, Gelber PE, Shehata TMA, Pelfort X, Monllau JC (2016) Autograft soaking in vancomycin reduces the risk of infection after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 24:2724–2728

    Article  Google Scholar 

  17. Petinaki E, Kontos F, Miriagou V, Maniati M, Hatzi F, Maniatis AN (2001) Survey of methicillin-resistant coagulase-negative staphylococci in the hospitals of central Greece. Int J Antimicrob Agents 18:563–566

    Article  CAS  Google Scholar 

  18. Petinaki E, Miriagou V, Tzouvelekis LS, Pournaras S, Hatzi F, Kontos F, Maniati M, Maniatis AN (2001) Methicillin-resistant Staphylococcus aureus in the hospitals of Central Greece. Int J Antimicrob Agents 18:61–65

    Article  CAS  Google Scholar 

  19. Phegan M, Grayson JE, Vertullo CJ (2016) No infections in 1300 anterior cruciate ligament reconstructions with vancomycin pre-soaking of hamstring grafts. Knee Surg Sports Traumatol Arthrosc 24:2729–2735

    Article  Google Scholar 

  20. Schollin-Borg M, Michaëlsson K, Rahme H (2003) Presentation, outcome, and cause of septic arthritis after anterior cruciate ligament reconstruction: a case control study. Arthroscopy 19:941–947

    Article  Google Scholar 

  21. Schub DL, Schmitz LM, Sakamoto FA, Winalski CS, Parker RD (2012) Long-term outcomes of postoperative septic arthritis after anterior cruciate ligament reconstruction. Am J Sports Med 40:2764–2770

    Article  Google Scholar 

  22. Schuster P, Schlumberger M, Mayer P, Eichinger M, Geßlein M, Richter J (2019) Soaking of autografts in vancomycin is highly effective in preventing postoperative septic arthritis after revision anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc. https://doi.org/10.1007/s00167-019-05820-9

    Article  PubMed  Google Scholar 

  23. Schüttler KF, Scharm A, Stein T, Heyse TJ, Lohoff M, Sommer F, Spiess-Naumann A, Efe T (2019) Biomechanical and microbiological effects of local vancomycin in anterior cruciate ligament (ACL) reconstruction: a porcine tendon model. Arch Orthop Trauma Surg 139:73–78

    Article  Google Scholar 

  24. Sonnery-Cottet B, Thaunat M, Archbold P, Issartel B (2014) Management of septic arthritis following anterior cruciate ligament reconstruction: a review of current practices and recommendations. J Am Acad Orthop Surg 22:271–273

    Article  Google Scholar 

  25. Torres-Claramunt R, Pelfort X, Erquicia J, Gil-González S, Gelber PE, Puig L, Monllau JC (2013) Knee joint infection after ACL reconstruction: prevalence, management and functional outcomes. Knee Surg Sports Traumatol Arthrosc 21:2844–2849

    Article  CAS  Google Scholar 

  26. Vertullo CJ, Quick M, Jones A, Grayson JE (2012) A surgical technique using presoaked vancomycin hamstring grafts to decrease the risk of infection after anterior cruciate ligament reconstruction. Arthroscopy 28:337–342

    Article  Google Scholar 

  27. Wang C, Ao Y, Wang J, Hu Y, Cui G, Yu J (2009) Septic arthritis after arthroscopic anterior cruciate ligament reconstruction: a retrospective analysis of incidence, presentation, treatment, and cause. Arthroscopy 25:243–249

    Article  Google Scholar 

Download references

Funding

No funding was provided for this study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Michael E. Hantes.

Ethics declarations

Conflict of interest

The authors report no conflict of interest.

Ethical approval

IRB approval (13/18/29-10-2019, General University Hospital of Larisa).

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Banios, K., Komnos, G.A., Raoulis, V. et al. Soaking of autografts with vancomycin is highly effective on preventing postoperative septic arthritis in patients undergoing ACL reconstruction with hamstrings autografts. Knee Surg Sports Traumatol Arthrosc 29, 876–880 (2021). https://doi.org/10.1007/s00167-020-06040-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00167-020-06040-2

keywords

Navigation