A new online pre-concentration system using hydride generation atomic fluorescence spectrometry (HG AFS) for zinc determination in mineral water and isotonic sports drinks

Abstract

Mineral water and isotonic sports drinks (hydroelectrolytic supplement) are sources of electrolytes, and one among them is zinc, an important microelement for several functions of the body. In this study, a novel on-line preconcentration analytical method was developed and validated using atomic fluorescence spectrometry and chemical vapor generation to determine Zn, in mineral water and isotonic sports drinks employing multivariate optimization. The optimal parameters for the system were: pH = 8.00; [Na2CO3] = 6.5 × 10−3 mol L−1; sample flow = 5.70 mL min−1; flow rate = 8.00 mL min−1; and the elution flow rate was adjusted to 2.40 mL min−1 to obtain the analytical speed. The method to determine zinc in samples showed adequate linearity, repeatability and accuracy. The limits of detection (LOD) and quantification (LOQ) obtained for zinc were 0.03 and 0.09 μg L−1, respectively. Zinc concentration in mineral water and isotonic sports drinks ranged from 29.00 to 78.59 μg L−1. The enrichment factor (88.92) and sampling frequency/samples per hour (51) were obtained. Therefore, the results showed that the developed method is simple, fast, reliable, sensitive and selective for the determination of zinc in mineral water and isotonic sports drinks and can be applied in the control of the chemical and toxicological quality of these foods. Furthermore, the multivariate methodology using the complete factorial design and the Box–Behnken design was adequate for the optimization of the preconcentration system variables that influence the generation of the analytical signal.

Graphical abstract: A new online pre-concentration system using hydride generation atomic fluorescence spectrometry (HG AFS) for zinc determination in mineral water and isotonic sports drinks

Article information

Article type
Paper
Submitted
22 Jan 2020
Accepted
20 Feb 2020
First published
10 Mar 2020

Anal. Methods, 2020,12, 1711-1719

A new online pre-concentration system using hydride generation atomic fluorescence spectrometry (HG AFS) for zinc determination in mineral water and isotonic sports drinks

M. A. Pitta da Costa, D. L. França da Silva, F. de Souza Dias, A. de Freitas Santos Júnior and W. N. Lopes dos Santos, Anal. Methods, 2020, 12, 1711 DOI: 10.1039/D0AY00139B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements