Abstract
Ultrasound stimulation is thought to influence bone remodelling process. But recently, the efficiency of ultrasound therapy for bone healing has been questioned. Despite an extensive literature describing the positive effect of ultrasound on bone regeneration—cell cultures, animal models, clinical studies—there are more and more reviews denouncing the inefficiency of clinical devices based on low-intensity pulsed ultrasound stimulation (LIPUS) of the bone healing. One of the reasons to cause controversy comes from the persistent misunderstanding of the underlying physical and biological mechanisms of ultrasound stimulation of bone repair. As ultrasonic waves are mechanical waves, the process to be studied is the one of the mechanotransduction. Previous studies on the bone mechanotransduction have demonstrated the key role of the osteocytes in bone mechano-sensing. Osteocytes are bone cells ubiquitous inside the bone matrix; they are immersed in the interstitial fluid (IF) inside the lacuno-canalicular network (LCN). They are considered as particularly sensitive to a particular type of mechanical stress: wall shear stress on osteocytes due to the IF flow in the LCN. Inspired from these findings and observations, the present work investigates the effect of LIPUS on the cortical bone from the tissue to the osteocytes, considering that the impact of the ultrasound stimulation applied at the tissue scale is related to the mechanical stress experimented by the bone cells. To do that simulations based on the finite element method are carried out in the commercial software Comsol Multiphysics to assess the wall shear stress levels induced by the LIPUS on the osteocytes. Two formulations of the wall shear stress were investigated based on two IF flow models inside the LCN and associated with two different values of the LCN permeability. The wall shear stress estimate is very different depending on the assumption considered. One of these two models provides wall shear stress values in accordance with previous works published on bone mechanotransduction. This study presents the preliminary results of a computational model that could provide keys to understanding the underlying mechanisms of the LIPUS.
Similar content being viewed by others
References
Ali D, Sen S (2018) Permeability and fluid flow-induced wall shear stress of bone tissue scaffolds: computational fluid dynamic analysis using newtonian and non-newtonian blood flow models. Comput Biol Med 99:201–208
Anderson EJ, Kaliyamoorthy S, Iwan J, Alexander D, Knothe Tate ML (2005) Nano-microscale models of periosteocytic flow show differences in stresses imparted to cell body and processes. Ann Biomed Eng 33(1):52–62
Aspenberg P (2017) Comment to a BMJ EditorialIs LIPUS the baby in the bathwater? Acta Orthop 88(1):1
Bacabac RG, Smit TH, Mullender MG, Dijcks SJ, Van Loon JJWA, Klein-Nulend J (2004) Nitric oxide production by bone cells is fluid shear stress rate dependent. Biochem Biophys Res Commun 315(4):823–829
Bakker AD, Soejima K, Klein-Nulend J, Burger EH (2001) The production of nitric oxide and prostaglandin E2 by primary bone cells is shear stress dependent. J Biomech 34(5):671–677
Biot MA (1955) Theory of elasticity and consolidation for a porous anisotropic solid. J Appl Phys 26(2):182–185
Biot MA (1957) The elastic coefficients of the theory of consolidation. J Appl Mech 24:594–601
Bonewald LF (2011) The amazing osteocyte. J Bone Min Res 26(2):229–238
Burra S, Nicolella DP, Francis WL, Freitas CJ, Mueschke NJ, Poole K, Jiang JX (2010) Dendritic processes of osteocytes are mechanotransducers that induce the opening of hemichannels. Proc Natl Acad Sci USA 107(31):13648–13653
Busse JW, Bhandari M, Einhorn TA, Heckman JD, Leung K-S, Schemitsch E, Tornetta P, Walter SD, Guyatt GH (2014) Trial to re-evaluate ultrasound in the treatment of tibial fractures (TRUST): a multicenter randomized pilot study. Trials 15:206
Buza JA, Einhorn T (2016) Bone healing in 2016. Clin Cases Min Bone Metab 13:101–105
Cardoso L, Fritton SP, Gailani G, Benalla M, Cowin SC (2013) Advances in assessment of bone porosity, permeability and interstitial fluid flow. J Biomech 46(2):253–265
Chan CW, Qin L, Lee KM, Zhang M, Cheng JCY, Leung Kwok S (2006) Low intensity pulsed ultrasound accelerated bone remodeling during consolidation stage of distraction osteogenesis. J Orthop Res 24(2):263–270
Claes LE, Heigele CA (1999) Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing. J Biomech 32(3):255–266
Claes LE, Willie B (2007) The enhancement of bone regeneration by ultrasound. Prog Biophys Mol Biol 93(1–3):384–398
Corradi C, Cozzolino A (1953) Effect of ultrasonics on the development of osseous callus in fractures. Arch Ortop 66(1):77–98
Coussy O (2005) Thermoporoelasticity. In: Poromechanics. Wiley, pp 71–112
Cowin SC (2003) A recasting of anisotropic poroelasticity in matrices of tensor components. Transp Porous Media 50(1):35–56
Cowin SC, Moss-Salentijn L, Moss ML (1991) Candidates for the mechanosensory system in bone. J Biomech Eng 113(2):191–197
Duarte LR (1983) The stimulation of bone growth by ultrasound. Arch Orthop Trauma Surg 101(3):153–159
Fan L, Pei S, Lucas L. X, Wang L (2016) A multiscale 3d finite element analysis of fluid/solute transport in mechanically loaded bone. Bone Res 4:16032
González-Torres LA, Gómez-Benito MJ, Doblaré M, García-Aznar JM (2010) Influence of the frequency of the external mechanical stimulus on bone healing: a computational study. Med Eng Phys 32(4):363–371
Goulet GC, Hamilton N, Cooper D, Coombe D, Tran D, Martinuzzi R, Zernicke RF (2008) Influence of vascular porosity on fluid flow and nutrient transport in loaded cortical bone. J Biomech 41(10):2169–2175
Griffin XL (2016) Low intensity pulsed ultrasound for fractures of the tibial shaft. BMJ 355:i5652
Gómez-Benito MJ, González-Torres LA, Reina-Romo E, Grasa J, Seral B, García-Aznar JM (2011) Influence of high-frequency cyclical stimulation on the bone fracture-healing process: mathematical and experimental models. Philos Trans R Soc Lond A Math Phys Eng Sci 369(1954):4278–4294
Han Y, Cowin SC, Schaffler MB, Weinbaum S (2004) Mechanotransduction and strain amplification in osteocyte cell processes. Proc Natl Acad Sci 101(47):16689–16694
Isaksson H, Wilson W, van Donkelaar CC, Huiskes R, Ito K (2006) Comparison of biophysical stimuli for mechano-regulation of tissue differentiation during fracture healing. J Biomech 39(8):1507–1516
Klein-Nulend J, van der Plas A, Semeins CM, Ajubi NE, Frangos JA, Nijweide PJ, Burger EH (1995) Sensitivity of osteocytes to biomechanical stress in vitro. FASEB J 9(5):441–445
Klein-Nulend J, Bacabac RG, Mullender MG (2005) Mechanobiology of bone tissue. Pathol Biol 53(10):576–580
Klein-Nulend J, Bakker AD, Bacabac RG, Vatsa A, Weinbaum S (2013) Mechanosensation and transduction in osteocytes. Bone 54(2):182–190
Lacroix D, Prendergast PJ (2002) A mechano-regulation model for tissue differentiation during fracture healing: analysis of gap size and loading. J Biomech 35(9):1163–1171
Lemaire T, Lemonnier S, Naili S (2012) On the paradoxical determinations of the lacuno-canalicular permeability of bone. Biomech Model Mechanobiol 11:933–946
Martinez de Albornoz P, Khanna A, Longo UG, Forriol F, Maffulli N (2011) The evidence of low-intensity pulsed ultrasound for in vitro, animal and human fracture healing. Br Med Bull 100(1):39–57
Mortazavi SMJ, Mortazavi SAR, Paknahad M (2016) Mode & mechanism of low intensity pulsed ultrasound (LIPUS) in fracture repair. Ultrasonics 71:142
Mullender MG, Huiskes R (1997) Osteocytes and bone lining cells: which are the best candidates for mechano-sensors in cancellous bone? Bone 20(6):527–532
Mullender MG, El Haj AJ, Yang Y, van Duin MA, Burger EH, Klein-Nulend J (2004) Mechanotransduction of bone cells in vitro: mechanobiology of bone tissue. Med Biol Eng Comput 42(1):14–21
Nguyen V-H, Naili S (2012) Simulation of ultrasonic wave propagation in anisotropic poroelastic bone plate using hybrid spectral/finite element method. Int J Numer Methods Biomed Eng 28(8):861–876
Nguyen V-H, Lemaire T, Naili S (2009) Numerical study of deformation-induced fluid flows in periodic osteonal matrix under harmonic axial loading. C R Mec 337:268–276
Nguyen V-H, Lemaire T, Naili S (2010a) Poroelastic behaviour of cortical bone under harmonic axial loading: a finite element study at the osteonal scale. Med Eng Phys 32:384–390
Nguyen V-H, Sansalone V, Naili S (2010b) Simulation of ultrasonic wave propagation in anisotropic cancellous bone immersed in fluid. Wave Motion 47(2):117–129
Nguyen V-H, Lemaire T, Naili S (2011) Influence of interstitial bone microcracks on strain-induced fluid flow. Biomech Model Mechanobiol 10:963–972
Ouyang P, Dong H, He X, Cai X, Wang Y, Li J, Li H, Jin Z (2019) Hydromechanical mechanism behind the effect of pore size of porous titanium scaffolds on osteoblast response and bone ingrowth. Mater Des 183:108151
Padilla F, Puts R, Vico L, Raum K (2014) Stimulation of bone repair with ultrasound: a review of the possible mechanic effects. Ultrasonics 54(5):1125–1145
Poolman R, Agoritsas T, Siemieniuk R, Harris I, Schipper I, Mollon B, Smith M, Albin A, Nador S, Sasges W, Schandelmaier S, Lytvyn L, Kuijpers T, Van Beers L, Verhofstad M, Vandvik P (2017) Low intensity pulsed ultrasound (LIPUS) for bone healing: a clinical practice guideline. BMJ 356:j576
Prendergast PJ, Huiskes R, Søballe K (1997) Biophysical stimuli on cells during tissue differentiation at implant interfaces. J Biomech 30(6):539–548
Robling AG, Turner CH (2009) Mechanical signaling for bone modeling and remodeling. Crit Rev Eukaryot Gene Expr 19(4):319–338
Rosi G, Nguyen V-H, Naili S (2016) Numerical investigations of ultrasound wave propagating in long bones using a poroelastic model. Math Mech Solids 21(1):119–133
Schandelmaier S, Kaushal A, Lytvyn L, Heels-Ansdell D, Siemieniuk RAC, Agoritsas T, Guyatt GH, Vandvik PO, Couban R, Mollon B, Busse JW (2017) Low intensity pulsed ultrasound for bone healing: systematic review of randomized controlled trials. BMJ 356:j656
Scheiner S, Pivonka P, Hellmich C (2016) Poromicromechanics reveals that physiological bone strains induce osteocyte-stimulating lacunar pressure. Biomech Model Mechanobiol 15(1):9–28
Schortinghuis J, Stegenga B, Raghoebar GM, de Bont LGM (2003) Ultrasound stimulation of maxillofacial bone healing. Crit Rev Oral Biol Med 14(1):63–74
Smit TH, Huyghe JM, Cowin SC (2002) Estimation of the poroelastic parameters of cortical bone. J Biomech 35(6):829–835
Swan CC, Lakes RS, Brand RA, Stewart KJ (2003) Micromechanically based poroelastic modeling of fluid flow in haversian bone. J Biomech Eng 125(1):25–37
Thompson M, Willis JR (1991) A reformation of the equations of anisotropic poroelasticity. J Appl Mech 58(3):612–616
Wang DM, Tarbell JM (1995) Modeling interstitial flow in an artery wall allows estimation of wall shear stress on smooth muscle cells. J Biomech Eng 117(3):358–363
Weinbaum S, Cowin SC, Zeng Yu (1994) A model for the excitation of osteocytes by mechanical loading-induced bone fluid shear stresses. J Biomech 27(3):339–360
Wu L, Lin L, Qin Y-X (2015) Enhancement of cell ingrowth, proliferation, and early differentiation in a three-dimensional silicon carbide scaffold using low-intensity pulsed ultrasound. Tissue Eng Part A 21(1–2):53–61
Yasuda I (1977) The classic: fundamental aspects of fracture treatment by Iwao Yasuda, reprinted from J. Kyoto Med. Soc., 4:395–406 (1953). Clin Orthop Relat Res 124:5–8
Zhang D, Weinbaum S, Cowin SC (1998) Estimates of the peak pressures in bone pore water. J Biomech Eng 120(6):697–703
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Baron, C., Nguyen, VH., Naili, S. et al. Interaction of ultrasound waves with bone remodelling: a multiscale computational study. Biomech Model Mechanobiol 19, 1755–1764 (2020). https://doi.org/10.1007/s10237-020-01306-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10237-020-01306-7