Vet Comp Orthop Traumatol 2020; 33(02): 137-141
DOI: 10.1055/s-0039-3400486
Original Research
Georg Thieme Verlag KG Stuttgart · New York

Stifle Joint Rotational Variation in Extended Stifles in Healthy Dogs Undergoing Computed Tomography Examinations

Clara M. Allberg
1   Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Frederiksberg C, Denmark
,
Fintan J. McEvoy
1   Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Frederiksberg C, Denmark
,
Lene E. Buelund
1   Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Frederiksberg C, Denmark
,
James E. Miles
1   Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Frederiksberg C, Denmark
› Author Affiliations
Funding This study was performed with institutional funding and received no external funding.
Further Information

Publication History

01 March 2019

10 October 2019

Publication Date:
08 January 2020 (online)

Abstract

Objectives The aim of this study was to evaluate stifle joint rotational stability in response to body position and repositioning in dogs undergoing computed tomography (CT).

Materials and Methods Nine dogs (18 stifles) with no history or clinical signs of stifle injury undergoing CT examinations for other reasons were included in the study. Dogs were positioned in alternating dorsal and sternal recumbency with the pelvic limbs extended caudally and unrestrained, for a total of four examinations. Scans included the entire tibia and distal femur. Using defined landmarks on the tibia and femur, stifle joint rotational angles were measured from multiplanar reconstructions made by two independent observers, and repositioning effects and intra- and interobserver agreement evaluated.

Results Repositioning produced repeatable stifle joint rotational angles (pooled within-subject standard deviations of 0.9° and 1.4°) and intraobserver repeatability was good (within-subject standard deviations 1.4°), but interobserver agreement was poor. Dorsal and sternal positioning produced equivalent results.

Clinical Significance The results indicate that little rotation occurs in the healthy extended canine stifle joint during positioning for CT and support CT as a method for assessing limb alignment around the stifle joint, provided that the limb distal to the femorotibial joint is unrestrained. Clinically, it is likely that measured changes in rotational angles across (and distant to) the stifle joint are real, rather than being due to rotation artefact during imaging.

Authors' Contributions

CMA contributed to acquisition of data, data analysis and interpretation and production of the initial manuscript. JEM contributed to conception of study, study design, acquisition of data, data analysis and interpretation. LEB contributed to study design. All authors were involved in drafting, revision and approval of the submitted manuscript.


 
  • References

  • 1 Piermattei DL. The stifle joint. In: Piermattei DL, Flo GF, Decamp CE. , eds. Handbook of Small Animal Orthopedics and Fracture Repair. 4th ed. St Louis, MO: Saunders Elsevier; 2006: 562-632
  • 2 Bound N, Zakai D, Butterworth SJ, Pead M. The prevalence of canine patellar luxation in three centres. Clinical features and radiographic evidence of limb deviation. Vet Comp Orthop Traumatol 2009; 22 (01) 32-37
  • 3 L'Eplattenier H, Montavon PM. Patellar luxation in dogs and cats: pathogenesis and diagnosis. Compend Contin Educ Pract Vet 2002; 24: 234-240
  • 4 Lusetti F, Bonardi A, Eid C, Brandstetter de Belesini A, Martini FM. Pelvic limb alignment measured by computed tomography in purebred English Bulldogs with medial patellar luxation. Vet Comp Orthop Traumatol 2017; 30 (03) 200-208
  • 5 Oxley B, Gemmill TJ, Pink J. , et al. Precision of a novel computed tomographic method for quantification of femoral varus in dogs and an assessment of the effect of femoral malpositioning. Vet Surg 2013; 42 (06) 751-758
  • 6 Soparat C, Wangdee C, Chuthatep S, Kalpravidh M. Radiographic measurement for femoral varus in Pomeranian dogs with and without medial patellar luxation. Vet Comp Orthop Traumatol 2012; 25 (03) 197-201
  • 7 Swiderski JK, Radecki SV, Park RD, Palmer RH. Comparison of radiographic and anatomic femoral varus angle measurements in normal dogs. Vet Surg 2008; 37 (01) 43-48
  • 8 Dudley RM, Kowaleski MP, Drost WT, Dyce J. Radiographic and computed tomographic determination of femoral varus and torsion in the dog. Vet Radiol Ultrasound 2006; 47 (06) 546-552
  • 9 Olimpo M, Piras LA, Peirone B. Pelvic limb alignment in small breed dogs: a comparison between affected and free subjects from medial patellar luxation. Vet Ital 2016; 52 (01) 45-50
  • 10 Ginja MMD, Gonzalo-Orden JM, Jesus SS, Silvestre AM, Llorens-Pena MP, Ferreira AJA. Measurement of the femoral neck anteversion angle in the dog using computed tomography. Vet J 2007; 174 (02) 378-383
  • 11 Dismukes DI, Fox DB, Tomlinson JL, Cook JL, Essman SC. Determination of pelvic limb alignment in the large-breed dog: a cadaveric radiographic study in the frontal plane. Vet Surg 2008; 37 (07) 674-682
  • 12 Slocum B, Slocum TD. The Knee. In: Bojrab MJ. , ed. Current Techniques in Small Animal Surgery; Vol. 4. Baltimore, Maryland, USA: Williams and Wilkins; 1998: 1187-1244
  • 13 Miles JE, Mortensen M, Svalastoga EL, Eriksen T. A comparison of anatomical lateral distal femoral angles obtained with four femoral axis methods in canine femora. Vet Comp Orthop Traumatol 2015; 28 (03) 193-198
  • 14 Miles JE. Femoral rotation unpredictably affects radiographic anatomical lateral distal femoral angle measurements. Vet Comp Orthop Traumatol 2016; 29 (02) 156-159
  • 15 Jackson GM, Wendelburg KL. Evaluation of the effect of distal femoral elevation on radiographic measurement of the anatomic lateral distal femoral angle. Vet Surg 2012; 41 (08) 994-1001
  • 16 Miles JE, Jensen BR, Kirpensteijn J, Svalastoga EL, Eriksen T. Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers. Am J Vet Res 2013; 74 (06) 888-894
  • 17 Kaiser S, Cornely D, Golder W, Garner M, Waibl H, Brunnberg L. Magnetic resonance measurements of the deviation of the angle of force generated by contraction of the quadriceps muscle in dogs with congenital patellar luxation. Vet Surg 2001; 30 (06) 552-558
  • 18 Towle HA, Griffon DJ, Thomas MW, Siegel AM, Dunning D, Johnson A. Pre- and postoperative radiographic and computed tomographic evaluation of dogs with medial patellar luxation. Vet Surg 2005; 34 (03) 265-272
  • 19 Vasseur PB, Arnoczky SP. Collateral ligaments of the canine stifle joint: anatomic and functional analysis. Am J Vet Res 1981; 42 (07) 1133-1137
  • 20 Clarke K, Hall L. A survey of anaesthesia in small animal practice: AVA/BSAVA report. Vet Anaesth Analg 1990; 17: 4-10
  • 21 Bland JM, Altman DG. Measurement error [published correction appears in BMJ 1996;313(7059):744]. BMJ 1996; 312 (7047): 1654
  • 22 Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999; 8 (02) 135-160
  • 23 Barnes DM, Anderson AA, Frost C, Barnes J. Repeatability and reproducibility of measurements of femoral and tibial alignment using computed tomography multiplanar reconstructions. Vet Surg 2015; 44 (01) 85-93