Pretreatment for the reclamation of rendering plant secondary effluent with NF/RO: UF flat sheet versus UF hollow fiber membranes

  • Original Paper
  • Published:
Clean Technologies and Environmental Policy Aims and scope Submit manuscript

Abstract

Rendering plants produce large amounts of wastewater that could be reused at the plant with adequate treatment. Membrane fouling is the main problem during the treatment of this type of wastewater by nanofiltration (NF) and reverse osmosis (RO). In order to reduce membrane fouling, the rendering plant secondary effluent was pretreated with two types of ultrafiltration (UF) membranes: MW as a flat sheet and ZW-1 as a hollow fiber membrane. The fouling on NF/RO flat sheet membranes (NF90, NF270, and XLE) was evaluated with the resistance-in-series model, while the fouling mechanisms were assessed with crossflow models. The UF, NF, and RO permeates were characterized to determine its suitability for reuse in the rendering plant. ZW-1 reduced the flux decline by 67.0% for NF270, 1.6% for NF90, and 38.0% for XLE; while MW reduced the flux decline by 72.4% for NF270, 50.1% for NF90, and 68.1% for XLE. The pretreatment with MW resulted in higher fouling reduction and a permeate that is appropriate for industrial reuse (washing purposes in the rendering plant). In terms of fouling resistance, NF270 and XLE membranes showed less fouling resistance during the treatment compared to NF90. The highest quality of permeate was obtained with XLE membrane, satisfying the water requirements for steam generation. The predominant fouling mechanisms for NF/RO were partial and complete pore blocking. The best combination for rendering plant secondary effluent reclamation was UF with MW membrane and RO with XLE membrane.

Graphic abstract

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

Download references

Acknowledgements

This study has been financed by The Government of the Republic of Croatia within Program for encouraging research and development activities in the field of climate change for period 2015 and 2016 with support of The Ministry of Science and Education, The Ministry of Environmental and Nature Protection, The Environmental Protection and Energy Efficiency Fund, and The Croatian Science Foundation under the project Direct reuse of municipal wastewater for agriculture irrigation with membrane technologies (ReHOHMem) (PKP-2016-06-8522).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Racar.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary material 1 (PDF 429 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Racar, M., Obajdin, K., Dolar, D. et al. Pretreatment for the reclamation of rendering plant secondary effluent with NF/RO: UF flat sheet versus UF hollow fiber membranes. Clean Techn Environ Policy 22, 399–408 (2020). https://doi.org/10.1007/s10098-019-01789-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10098-019-01789-8

Keywords

Navigation