Abstract

The fire resistance of concrete filled square steel tube columns (CFT columns) without fire protection under a constant axial load has been previously examined. The purpose of this present study is to investigate the fire resistance of CFT columns when they are subjected to combined loads. This paper presents a nonlinear thermal stress analysis method for predicting the mechanical behavior and fire resistance of CFT columns under eccentric axial load (axial load and flexure moment). This method is based on the stress-strain characteristics of materials at high temperatures and on the mechanics of column deflection curves. From the results of the developed computational technique, it was demonstrated that as the yield stress and rigidity of the steel tube rapidly decreased for approximately 30 minutes, the decrease of flexure moment capacity increased significantly more than that of the axial load capacity. In addition, as the load eccentricity ratio increased, the fire resistance time drastically decreased. However, the time of maximum expansion under eccentric axial load was independent of the load eccentricity ratio.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Architectural Institute of Japan. (1980). Standard for structural calculation of mixed tubular steel-concrete composite structure. 2nd Edition.

    Google Scholar 

  • Choi, S. M., Kim, D. K., Kim, J. H., Chung, K. S., and Park, S. H. (2005). “Experimental study on fire resistance of concrete-filled steel tube column under constant axial loads.” International J Steel Struct, 5(4), 305–13.

    Google Scholar 

  • Chung, K. S., Park, S. H., and Choi, S. M. (2008). “Material effect for predicting the fire resistance of concrete-filled square steel tube column under constant axial.” J Constr Steel Res, 64(12), 1105–15.

    Google Scholar 

  • Eurocode 4. Design of steel and composite structures. (1994). Part 1.2, Structural fire design. ENV, 1–2. 2003.

    Google Scholar 

  • Han, L. H. (2001). “Fire performance of concrete filled steel tubular beam-columns.” J Constr Steel Res, 57(6), 695–709.

    Google Scholar 

  • Ichinohe, Y., Suzuki, H., Kubota, K., Hirayama, H., Ueda, H., and Yutani, T. (2001). “Fire resistance of circular steel tube columns infilled with reinforced concrete.” J Struct and Constr Eng AIJ, 548, 167–74.

    Google Scholar 

  • Kimura, M., Ohta, H., Kaneko, H., and Kodaira, A. (1990). “Fire resistance of concrete-filled square steel tubular columns subjected to combined load.” J Struct and Constr Eng AIJ, 417, 63–70.

    Google Scholar 

  • Kodur, V. K. R. and Lie, T. T. (1996). “Fire resistance of circular steel columns filled with fiber-reinforced concrete.” J. Struct Eng ASCE, 122(7), 776–82.

    Google Scholar 

  • Poh, K. W. and Bennetts, I. D. (1995). “Analysis of structural members under elevated temperature conditions.” J. Struct Eng ASCE, 121(4), 664–75.

    Google Scholar 

  • Saito, H., Morita, T., and Uesugi, H. (2004). “Fire resistance of concrete-filled steel tube columns under constant axial loads.” J Enviro Eng AIJ, 582, 9–16.

    Google Scholar 

  • Yin, J., Zha, X. X., and Li, L. Y. (2006). “Fire resistance of axially loaded concrete filled steel tube columns.” J Constr Steel Res, 62(7), 723–9.

    Google Scholar 

  • Zha, X. X. (2003). “FE analysis of fire resistance of concrete filled CHS columns.” J Constr Steel Res, 59(6), 769–79.

    MathSciNet  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sungmo Choi.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Chung, K., Park, S. & Choi, S. Fire resistance of concrete filled square steel tube columns subjected to eccentric axial load. Int J Steel Struct 9, 69–76 (2009). https://doi.org/10.1007/BF03249481

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03249481

Keywords

Navigation