Four hours of veno-venous extracorporeal membrane oxygenation using bi-caval cannulation affects kidney function and induces moderate lung damage in a mouse model

Abstract

Background

Improvement of single site cannulation for extracorporeal membrane oxygenation (ECMO) therapy is pivotal for reduction of patient morbidity and mortality in respiratory failure. To further improve the cardiopulmonary outcomes and reduce end organ damage, we established a murine model for single site cannulation with a double lumen cannula.

Results

We created a hemodynamically stable double lumen cannula and successfully implanted it through the jugular vein into the upper and lower vena cava. This allowed adequate drainage of the blood. Blood gas analysis showed excellent oxygenation and CO2 reduction. There was no excessive bleeding. No signs of right heart congestion were present which was confirmed in the histological analysis of the liver. Histology demonstrated moderate lung damage and mild acute kidney injury. Neutrophil infiltration was similar in ECMO and sham kidneys.

Conclusions

Veno-venous extracorporeal circulation deteriorates kidney function and promotes moderate pulmonary damage.

Introduction

Extracorporeal membrane oxygenation (ECMO) is an essential tool in cardiorespiratory failure [1]. In isolated respiratory failure, veno-venous (vv)-ECMO is the therapy of choice as bridge to either recovery or transplantation [2]. In this setting, there are two cannulas placed in the veins of the patient. The draining cannula is typically placed through the femoral vein and advanced via the inferior vena cava to the right atrium. The returning cannula is typically placed in the right jugular vein and advanced to the border of the right atrium and upper vena cava. Through the membrane oxygenator, blood is supplied with oxygen and carbon dioxide is washed out. Indications for vv-ECMO implementation include severe acute respiratory distress syndrome (ARDS), exacerbation of chronic obstructive pulmonary disease (COPD), and as a bridge to lung transplantation [3, 4]. Although this system is highly effective, complications including bleeding, pneumothorax, and cannula infections have been reported during cannulation and ongoing ECMO therapy [2, 4, 5]. Moreover, patients on awake ECMO are difficult to mobilize when the femoral vein is cannulated. The use of a double lumen cannula has been proposed to optimize physiotherapy, patient mobilization, and patient comfort [6,7,8]. Additionally, placement of a double lumen cannula at a single site is less traumatic and has been proven to be very effective when CO2 elimination is needed. Major limitations of this system include reduced venous backflow [9], relatively low blood flow [10], cannula displacement, and thrombosis [11].

To further improve patient outcomes and reduce morbidity, a reliable and reproducible animal model is needed for research purposes. Based on our previously established mouse model of vv-ECMO [12], here we describe a novel murine double lumen cannula for vv-ECMO support.

Material and methods

Animals

Nineteen male C57Bl/6 mice were obtained from Charles River (Sulzfeld, Germany) and used for the experiments. Animals were randomly divided into sham-operated (n = 6) animals, 4 h vv-ECMO (n = 8) animals, and animals used in the design of the double lumen cannula (n = 5, see below). The weight of mice ranged between 25 and 35 g. This study was performed in compliance with the German Animal Protection Law (TierSchG) and was approved by the local animal welfare committee (Lower Saxony State Office for Consumer Protection and Food Safety, Protocol TSA 33.12-42502-04-16/2250).

Design and construction of the double lumen cannula

A 2F double lumen silicone-based catheter (Vygon GmbH & CO.KG Medizintechnik, Aachen, Germany) was used as the basis for the production of the double lumen cannula (Fig. 1). Using a sharp blade, outflow fenestrations were made in the catheter at the eventual site of the superior vena cava and inferior vena cava (Fig. 2). Similarly, inflow fenestrations were made at the height of the right atrium. To ensure optimal positioning of the fenestrations, multiple measurements were performed on five mouse cadavers of a similar age/size to the experimental mice. For optimal drainage and minimal shunting, venous outflow fenestrations were made 0.2 mm, 0.4 mm, and 20 mm from the distal end. Atrial inflow fenestrations were made 0.4 mm and 0.5 mm from the distal end. To prevent recirculation and shunting of the blood, the distal end of the inflow cannula lumen was sealed.

Fig. 1
figure 1

The two French double lumen cannula which were the basis for the double lumen single ECMO cannula. Ruler for reference in mm

Fig. 2
figure 2

Schematic depiction of the double lumen silicone cannula. Two lines were constructed into a single cannula. One line extracts blood (a) from the upper and lower vena cava before passing it through the oxygenator and giving the blood back in the right atrium (b). Blue (c) and red arrows (d) show the fenestrations in the cannula

Surgical procedure and extracorporeal membrane oxygenation

Surgical preparation (Fig. 3) and ECMO setup were carried out as previously described [12]. In brief, all animals were anesthetized with isoflurane mask narcosis (Fig. 3 (a)) and spontaneous breathing was maintained. Subcutaneous carprofen (Zoetis, Parsippany, NJ, USA) injections were given as additional analgesia (5 mg/kg body weight). Perfusion solution consisted of a 1:1 solution of Tetraspan: Sterofundin (B Braun Medical, Melsungen, Hesse, Germany) that had been heparinized (30 IU/ml). Prior to cannulation, the ECMO circuit was primed with 500 μl of perfusion solution. Buffering of the solution was carried out using 2.5% v/v of an 8.4% solution of sodium bicarbonate. An arterial pressure line in the left femoral artery was used for blood sampling and blood pressure monitoring.

Fig. 3
figure 3

Experimental setup with mask narcosis (a) and double lumen cannulation through the jugular vein (b). During vv-ECMO, blood was circulated via a self-made oxygenator and returned via the right atrium

For cannulation, a lateral skin incision on the left side of the neck was made to expose the left jugular vein. An 8-0 silk suture was placed cranially to ligate the distal segment, and a slip knot was placed at the proximal end of the vein. After introducing the double lumen cannula into the left jugular vein (Fig. 3 (b)), it was moved 3.5 cm in the direction of the superior vena cava, and further into the inferior vena cava. The cannula was then secured using slip-knots. After confirmation of correct position of the cannula, extracorporeal circulation was started and continued for 4 h. In the sham group, the surgical procedure for cannulation was identical to the ECMO animals; however, no extracorporeal circulation was commenced. In both ECMO- and sham-treated animals, the procedure was performed for 4 h.

Blood gas analysis

Blood gas analysis (BGA) was performed from blood sampled from the femoral artery to evaluate the oxygenation and metabolic state of animals undergoing vv-ECMO.

Blood tests of kidney and liver function

Blood samples were collected via the femoral artery prior to the procedure and via exsanguination after termination of the experiment. Serum was stored at − 20 °C for later analysis. Clinical chemistry was done using an Olympus analyzer (AU 400) according to the manufacturer’s instructions to evaluate liver enzymes (glutamate oxaloacetate transaminase (GOT) and glutamate pyruvate transaminase (GPT)) and kidney function (creatinine, urea) after vv-ECMO. All values were corrected for hemodilution as previously described [13]. Furthermore, to evaluate hemolysis during the experiment, lactate dehydrogenase (LDH) values were compared between the start of the experiment and after 4 hours.

Histology

For organ fixation, lungs were filled with 4% paraformaldehyde via injection into the trachea. Filled lungs were explanted and incubated in 4% formalin overnight at 4 °C. After dehydration and deparaffinization, lungs were stained with hematoxylin and eosin (H&E) and histologically assessed for pulmonary damage. The liver and kidney were also collected, fixed in 4% paraformaldehyde, and stored for 24 h at 4 °C. Two-micrometer paraffin sections were stained with periodic acid-Schiff (PAS) to evaluate kidney and liver morphology. Assessment of acute kidney injury (AKI) and liver damage was done using a method previously described [13].

Statistics

Statistical analyses were performed using GraphPad Prism version 5.0 software (GraphPad Software Inc., San Diego, CA, USA). The Kolmogorov-Smirnov test revealed the data was normally distributed. One-way ANOVA with post hoc Bonferroni tests were used for statistical analysis. Unless otherwise stated, data are presented as mean ± standard deviation (SD).

Results

Hemodynamics and oxygenation after 4-h sham and ECMO treatment

During the experiments, stable hemodynamics were observed. No excessive blood loss was noted, and this was confirmed by the relatively stable hematocrit (Hct) and hemoglobin (Hb) values. Sham-operated animals had an initial Hct value of 42.5 ± 0.9%, which dropped after 4 h to 38.3 ± 0.9% (not significant, n.s.) due to regular blood samplings (Fig. 4a). In general, approximately 150 μl of blood was taken over the course of the experiment to analyze BGA in both arterial and venous blood. There was a similar drop in Hct seen in the vv-ECMO-treated group with an initial value of 24.5 ± 1.3% and an end value of 18.3 ± 1.7% (p = 0.027) (Fig. 4a). A significantly lower hematocrit was measured after 4 h of ECMO in comparison to 4 h sham (p = 0.0016) (Fig. 4a). These findings were comparable to our previous data [14], and the lower values were due to hemodilution.

Fig. 4
figure 4

Hematocrit (a) and hemoglobin (b) values of sham-operated (n = 6) and 4-hour ECMO-treated (n = 8) animals significantly decreased over the course of the experiment. All values are given as mean ± SD.*p < 0.05; **p < 0.01, ***p < 0.0001, ns not significant

Hemoglobin showed a similar drop over the course of the experiments. The initial level of Hb of 13.6 ± 0.2 g/dL in the sham group was in the normal range and significantly dropped during the experiment to 12.2 ± 0.3 g/dL (p = 0.003) due to blood sampling (Fig. 4b). Although not statistically significant, a fall in hemoglobin from 8.7 ± 0.4 to 7.2 ± 0.4 g/dL was observed in the ECMO treatment group (p = 0.059), probably due to hemolysis caused by the ECMO.

To ensure proper membrane oxygenator function, blood sampling was performed directly before and after the oxygenator following initiation of vv-ECMO. Pre-oxygenator pO2 (113.0 ± 14.1 mmHg) and post-oxygenator pO2 (680.9 ± 19.2 mmHg) showed a significant increase (p < 0.0001) indicating an excellent oxygenation capacity of our membrane oxygenator (Fig. 5a). To evaluate animal oxygenation, arterial BGAs were taken at the beginning of the experiment and were compared to BGAs taken after 4 h. Once initiated, ECMO was associated with high pO2 levels, which did not significantly change during the 4-h course of ECMO (p = 0.09) (Fig. 5b). After 4 h, the ECMO group showed a significantly higher arterial pO2 (567.1 ± 56.1 mmHg) (p < 0.001) compared to the sham group (312.0 ± 23.4 mmHg) (Fig. 5b). No significant differences in arterial pCO2 were recorded between the start and end of the experiment in the sham or ECMO groups (Fig. 5b). Similarly, no significant differences in venous pH or sO2 were observed between the start and end of the experiment for sham- or ECMO-treated animals (data not shown).

Fig. 5
figure 5

Blood gas analysis (BGA) was performed to ensure proper function of the oxygenator (a). pO2 (b, c) and pCO2 (d, e) values were evaluated in the ECMO animals (n = 8) and sham animals (n = 6). All values are given as mean ± SD.*p < 0.05; **p < 0.01, ***p < 0.0001, ns not significant

Venous blood taken from the inferior vena cava showed better pO2 values after 4-h ECMO therapy (p = 0.036) compared to the sham animals (Fig. 5c). There was no significant rise in venous blood pO2 after 4-h ECMO compared to start of the experiment (p = 0.17). No significant decrease in pCO2 values was seen over the course of 4 h in either sham- or ECMO-treated animals (Fig. 5d, e).

Evaluation of organ damage after 4-h sham or ECMO treatment

Four hours after either sham operation or vv-ECMO with the double lumen single cannulation technique, organ damage was evaluated. No pulmonary pathology was seen after 4 h in the sham group (Fig. 6a, c, e). Although the ECMO-treated animals showed regular bronchial and vascular architecture, small peripheral vessel coagulopathy was more frequently observed compared to sham-operated animals (Fig. 6).

Fig. 6
figure 6

Effect of ECMO treatment on lung histology. Shown are representative images of animals in either the sham (a, c, e) or ECMO oxygenation group (b, d, f) at the end of the procedure. Both groups showed normal bronchial and vascular architecture and normal general lung histology. Interestingly, animals treated with 4-h ECMO oxygenation frequently showed peripheral small vessel coagulopathy. Original magnifications × 2 (a, b), × 10 (c, d), and × 40 (e, f)

Next, renal function and kidney histology were assessed. Significant differences in serum creatinine and urea (p < 0.001) were seen after ECMO treatment compared to sham-operated animals (Fig. 7a, b). These differences may be due to either pre-renal acute kidney injury or hemolysis. Quantitative scoring (Fig. 7c) and histological evaluation (Fig. 7d, e) of the kidney showed a significant increase in the AKI (p = 0.040) score in the ECMO group, suggesting decreased renal function after vv-ECMO. Furthermore, although more GR-1 staining due to neutrophil infiltration was seen in the kidney after 4-h ECMO compared to sham-treated animals (Fig. 7f, g), quantitative scoring did not reach significance (p = 0.845).

Fig. 7
figure 7

Renal function and kidney histology. Clinical chemistry showed significantly elevated serum creatinine and urea in the ECMO group (a, b). Quantification of kidney damage after PAS stain was done by AKI score which showed mild AKI with distended tubuli in the ECMO group and almost normal renal morphology in sham kidneys (c, d, g). GR-1 neutrophil infiltration slightly increased after ECMO in glomeruli and in the tubulo interstitial space (e, f, h). All values are given as mean ± SD.*p < 0.05; **p < 0.01, ***p < 0.001, ns not significant (bar represents 100 μm)

After 4 h, blood tests for liver function revealed no significant differences between ECMO- and sham-treated animals (Fig. 8a, b). Congestive hepatopathy can occur upon congestive heart failure, but this data suggests right heart congestion did not occur during the procedure. No histological abnormalities were seen in the H&E- and PAS-stained cardiac samples (data not shown). As another measure of tissue damage, LDH was measured in the blood. After 4 h, a significant increase in LDH concentration was seen in ECMO-treated animals compared to sham treatment (p < 0.001) (Fig. 8c).

Fig. 8
figure 8

Clinical chemistry and histology of the liver. Blood samples taken after 4 h showed no significant elevation in GOT and GPT in the ECMO animals when compared to sham animals (a, b). LDH was significantly elevated in the ECMO treatment group compared to the sham group (c). Although histological evaluation of the liver did show reduced glycogen storage capacity in the ECMO group (d, e) compared to the sham group, this was not statistically significant (f). All values are given as mean ± SD.*p < 0.05; **p < 0.01, ***p < 0.0001, ns not significant (bar represents 1000 μm)

Liver pathology was evaluated using PAS staining and showed various extents of irregular glycogen loss in all animals (Fig. 8d, e). However, there were no signs of necrosis, cellular infiltration, or edema in liver tissue. Furthermore, quantification of glycogen storage defects (Fig. 8f) did not show a significant difference in either treatment group (p = 0.75).

Discussion

Animal models of bi-caval ECMO are rare, with to date, only two swine models being described [15, 16]. To our knowledge, no papers on bi-caval double lumen ECMO in a murine model have been published, making this a novel model. Although the classic two cannula vv-ECMO has become increasingly popular in patients with respiratory failure, this modality has its limitations. In small pediatric patients, there is no possibility for a second cannula as the femoral veins are often too small for cannulation. As previously stated, patient immobilization due to ECMO makes physical therapy practically impossible and may prolong the intensive care unit stay. In awake ECMO patients, ECMO tolerability is much greater and was not associated with an increase in complications such as bleeding [8, 10]. For this group of patients, a bi-caval double lumen cannula has been proposed as a therapeutic option [17]. This single cannula is inserted via the jugular vein and is ideally positioned using transesophageal echocardiography [18]. The main objective of vv-ECMO is carbon dioxide (CO2) elimination and, in part, supportive oxygenation in respiratory failure. Depending on the blood flow and diameter of the cannula, the rate of CO2 elimination can be regulated. Our new small animal model of double lumen ECMO is a proof of concept of the technique for potential future use to explore the pathomechanisms of SIRS, respiratory compensation in acute or end-stage lung disorders, and other systemic complications purely related to the blood damage caused by extracorporeal circulation. Additionally, there are commercially available genetically modified mice that develop, for example, respiratory insufficiency directly after birth or lung fibrosis in older age, in which ECMO could be studied in the context of these underlying diseases. Moreover, our cannulation technique can be successfully used in other experimental models involving dialysis, cytokine adsorbtion, plasmapheresis, or hemadsorbtion due to a similarity in function with other venous double lumen catheters widely used in the clinic.

Our results showed a feasible, hemodynamically stable setup with proper oxygenation and a trend of decreasing CO2 values. This suggests an optimized functioning of the oxygenator and a minimal shunting of the ECMO blood. No clinical signs of heart congestion were seen. Furthermore, clinical chemistry showed no increase in GOT and GPT values, thus making right heart congestion less probable. Increases in creatinine and urea values suggest a decrease in kidney function. Simultaneously, a significant increase in LDH was seen which may be explained due to hemolysis during ECMO. Hemolysis has previously been associated with impaired acute kidney failure after cardiopulmonary bypass [19]. Kidney failure during extracorporeal circulation is common and has multiple causes. In our model, the AKI was apparent with tubular damage upon histological assessment. Previous work showed an association between tubular damage and hemolysis, reduced renal blood flow, and hypoxia in ECMO [20,21,22,23,24]. AKI is an expected clinically relevant consequence of ECMO, and therefore, our model can be used to explore therapeutic interventions to prevent organ damage. In addition, due to the availability of a large number of genetically modified mouse strains, the model could also be used to investigate the molecular mechanisms leading to ECMO-related organ damage. As it is often difficult to distinguish whether complications seen clinically are caused by ECMO itself or arise from the underlying disorders accompanying acute and end-stage diseases, our model will allow researchers to specifically study the effects of ECMO on a healthy organism.

Our model did not show a significant drop in CO2 concentration in the arterial BGA over the course of a 4-h ECMO procedure. We believe this was due to spontaneous breathing of the animals. However, a clear trend in CO2 reduction was observed. A further reduction in CO2 values may be achieved by increasing gas flow or EMCO blood flow. Inducing a hypercapnic state in a mouse model would be beneficial to address this issue. As there are no small animal models available, we could not compare these findings. Large animal ECMO models, however, showed similar oxygenation results and comparable hemodynamics but did not report renal or hepatic function parameters [15, 16]. In conclusion, we present the proof-of-concept use of bi-caval double lumen ECMO in a murine model. Future projects include application of this model in a murine lung disease model to determine the outcome using different ECMO modalities.

Conclusion

Veno-venous extracorporeal membrane oxygenation elicits a decrease in renal function and significantly more histological renal damage. Furthermore, it induces pulmonary morphological changes after 4 h in a murine model. Liver function and histology does not seem to be affected, neither were there signs of right heart congestion.

Availability of data and materials

The datasets used or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

AKI:

Acute kidney injury

ARDS:

Acute respiratory distress syndrome

BGA:

Blood gas analysis

COPD:

Chronic obstructive pulmonary disease

ECMO:

Extracorporeal membrane oxygenation

GOT:

Glutamic oxaloacetic transaminase

GPT:

Glutamate pyruvate transaminase

Hb:

Hemoglobin

Hct:

Hematocrit

LDH:

Lactate dehydrogenase

n.s.:

Not significant

PAS:

Periodic acid-Schiff

SD:

Standard deviation

vv:

Veno-venous

References

  1. Tarzia V, Bortolussi G, Bianco R et al (2015) Extracorporeal life support in cardiogenic shock: impact of acute versus chronic etiology on outcome. J Thorac Cardiovasc Surg 150:333–340. https://doi.org/10.1016/j.jtcvs.2015.02.043

    Article  PubMed  Google Scholar 

  2. Kozinn J, Wrisinger CW (2019) ECMO for adults with severe respiratory failure. Mo Med 116:58–62

    PubMed  PubMed Central  Google Scholar 

  3. Tsiouris A, Budev MM, Yun JJ (2018) Extracorporeal membrane oxygenation as a bridge to lung transplantation in the United States: a multicenter survey. ASAIO J 64:689–693. https://doi.org/10.1097/MAT.0000000000000731

    Article  CAS  Google Scholar 

  4. Combes A, Hajage D, Capellier G et al (2018) Extracorporeal membrane oxygenation for severe acute respiratory distress syndrome. N Engl J Med 378:1965–1975. https://doi.org/10.1056/NEJMoa1800385

    Article  PubMed  Google Scholar 

  5. Vaquer S, de Haro C, Peruga P et al (2017) Systematic review and meta-analysis of complications and mortality of veno-venous extracorporeal membrane oxygenation for refractory acute respiratory distress syndrome. Ann Intensive Care 7:1–13. https://doi.org/10.1186/s13613-017-0275-4

    Article  Google Scholar 

  6. Kuhl T, Michels G, Pfister R et al (2015) Comparison of the Avalon dual-lumen cannula with conventional cannulation technique for venovenous extracorporeal membrane oxygenation. Thorac Cardiovasc Surg 63:653–662. https://doi.org/10.1055/s-0035-1549359

    Article  PubMed  Google Scholar 

  7. Chimot L, Marqué S, Gros A et al (2013) Avalon© bicaval dual-lumen cannula for venovenous extracorporeal membrane oxygenation: survey of cannula use in france. ASAIO J 59:157–161. https://doi.org/10.1097/MAT.0b013e31827db6f3

    Article  PubMed  Google Scholar 

  8. Hayes D, McConnell PI, Preston TJ et al (2013) Active rehabilitation with venovenous extracorporeal membrane oxygenation as a bridge to lung transplantation in a pediatric patient. World J Pediatr 9:373–374. https://doi.org/10.1007/s12519-013-0437-x

    Article  Google Scholar 

  9. Colombier S, Prêtre R, Iafrate M, Niclauss L (2016) Double-stage venous cannulation combined with Avalon® cannula for potential prolongation of respiratory ECMO in end-stage pulmonary disease. Perfus (United Kingdom) 31:593–597. https://doi.org/10.1177/0267659116641483

    Article  Google Scholar 

  10. Gothner M, Buchwald D, Strauch JT et al (2015) The use of double lumen cannula for veno-venous ECMO in trauma patients with ARDS. Scand J Trauma Resusc Emerg Med 23:1–6. https://doi.org/10.1186/s13049-015-0106-2

    Article  Google Scholar 

  11. Bermudez CA, Rocha RV, Sappington PL et al (2010) Initial experience with single cannulation for venovenous extracorporeal oxygenation in adults. Ann Thorac Surg 90:991–995. https://doi.org/10.1016/j.athoracsur.2010.06.017

    Article  PubMed  Google Scholar 

  12. Madrahimov N, Khalikov A, Boyle EC et al (2018) Veno-venous extracorporeal membrane oxygenation in a mouse. J Vis Exp:e58146–e58146. https://doi.org/10.3791/58146

  13. Natanov R, Gueler F, Falk CS et al (2018) Blood cytokine expression correlates with early multi-organ damage in a mouse model of moderate hypothermia with circulatory arrest using cardiopulmonary bypass. PLoS One 13:1–17. https://doi.org/10.1371/journal.pone.0205437

    Article  CAS  Google Scholar 

  14. Madrahimov N, Boyle EC, Gueler F et al (2017) Novel mouse model of cardiopulmonary bypass. Eur J Cardiothorac Surg:1–8. https://doi.org/10.1093/ejcts/ezx237

    Article  Google Scholar 

  15. Hayes D, Yates AR, Duffy VL et al (2014) Rapid placement of bicaval dual-lumen catheter in a swine model of venovenous ECMO. J Investig Surg 27:27–31. https://doi.org/10.3109/08941939.2013.826311

    Article  Google Scholar 

  16. Hayes D, Preston TJ, Davis IC et al (2013) Contrast transthoracic echocardiography and the placement of a bicaval dual-lumen catheter in a swine model of venovenous extracorporeal membrane oxygenation. Artif Organs 37:574–580. https://doi.org/10.1111/aor.12044

    Article  Google Scholar 

  17. Speggiorin S, Robinson SG, Harvey C et al (2015) Experience with the Avalon bicaval double-lumen veno-venous cannula for neonatal respiratory ECMO. Perfus (United Kingdom) 30:250–254. https://doi.org/10.1177/0267659114540020

    Article  CAS  Google Scholar 

  18. Jarboe MD, Gadepalli SK, Church JT et al (2018) Avalon catheters in pediatric patients requiring ECMO: placement and migration problems. J Pediatr Surg 53:159–162. https://doi.org/10.1016/j.jpedsurg.2017.10.036

    Article  Google Scholar 

  19. Wetz AJ, Richardt EM, Schotola H et al (2017) Haptoglobin and free haemoglobin during cardiac surgery - is there a link to acute kidney injury? Anaesth Intensive Care 45:58–66

    Article  CAS  Google Scholar 

  20. Villa G, Katz N, Ronco C (2015) Extracorporeal membrane oxygenation and the kidney. CardioRenal Med 6:50–60. https://doi.org/10.1159/000439444

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  21. Antonucci E, Lamanna I, Fagnoul D et al (2016) The impact of renal failure and renal replacement therapy on outcome during extracorporeal membrane oxygenation therapy. Artif Organs 40:746–754. https://doi.org/10.1111/aor.12695

    Article  CAS  PubMed  Google Scholar 

  22. Darby PJ, Kim N, Hare GMT et al (2013) Anemia increases the risk of renal cortical and medullary hypoxia during cardiopulmonary bypass. Perfusion 28:504–511. https://doi.org/10.1177/0267659113490219

    Article  CAS  PubMed  Google Scholar 

  23. Ranucci M, Aloisio T, Carboni G et al (2015) Acute kidney injury and hemodilution during cardiopulmonary bypass: a changing scenario. Ann Thorac Surg 100:95–100. https://doi.org/10.1016/j.athoracsur.2015.02.034

    Article  PubMed  Google Scholar 

  24. Vermeulen Windsant IC, de Wit NCJ, Sertorio JTC et al (2014) Hemolysis during cardiac surgery is associated with increased intravascular nitric oxide consumption and perioperative kidney and intestinal tissue damage. Front Physiol 5:1–9. https://doi.org/10.3389/fphys.2014.00340

    Article  Google Scholar 

Download references

Acknowledgements

We thank Slavia Schuemann for the excellent technical assistance in this project.

Funding

This research work was supported by German KFO 311 Deutsche Forschungs-gemeinschaft (DFG) Grant.

Author information

Authors and Affiliations

Authors

Contributions

NM contributed to the conceptualization. RN contributed to the data curation. RN and FG contributed to the formal analysis. NM and AH contributed to the funding acquisition. RN and AK contributed to the investigation. FG, AK, and NM contributed to the methodology. CK, UM, and NM contributed to the project administration. CK and UM contributed to the resources. FG, AH, and NM supervised the study. EB contributed to the validation. RN wrote the original draft. EB and NM wrote, reviewed, and edited the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Nodir Madrahimov.

Ethics declarations

Ethics approval and consent to participate

This study was performed in compliance with the German Animal Protection Law (TierSchG) and was approved by the local animal welfare committee (Lower Saxony State Office for Consumer Protection and Food Safety, Protocol TSA 33.12-42502-04-16/2250).

Consent for publication

Not applicable

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Natanov, R., Khalikov, A., Gueler, F. et al. Four hours of veno-venous extracorporeal membrane oxygenation using bi-caval cannulation affects kidney function and induces moderate lung damage in a mouse model. ICMx 7, 72 (2019). https://doi.org/10.1186/s40635-019-0285-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40635-019-0285-7

Keywords