Realization of Negative Gauge Pressure Standard in the National Metrology Institute of Indonesia

  • Original Paper
  • Published:
MAPAN Aims and scope Submit manuscript

Abstract

Accurate negative gauge pressure measurement is the key factor for many scientific and industrial applications such as clean room technology, medical treatment, and pharmaceutical production. However, there are not much publications regarding to the technical guide when it comes to negative pressure measurement, although several comparison of negative gauge pressure has been performed in Europe. In this study, two methods for negative pressure calibration have been successfully implemented by National Standardization Agency of Indonesia with using pressure balance. The first method is by generating the negative pressure in the bell jar of the pressure balance, and the second method is by using pressure balance in absolute pressure mode and additional barometric pressure measuring instrument. Both methods measurement results show linear relation from the negative to positive pressure and show good agreement by each other with the normalized error (En) less than 0.40 from – 1000 to 1000 hPa with uncertainty up to 0.073 hPa. The expanded uncertainty of the second method is relatively larger due to dominant contribution from the uncertainty of the barometer used. Therefore, it can be concluded that both methods can be used in order to provide traceability for negative gauge pressure measurement instrument in Indonesia.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. T.H. Tsao, C. P. Chang, C. Y. Chuang, Y. J. Juang, S. J. Lim, Y. T. Dai, The effect of doorway size on the negative pressure in airborne infection isolation room, J. Occup. Saf. Health, 18 (2010) 307–319.

    Google Scholar 

  2. N. Robert, Negative pressure wound therapy in orthopaedic surgery, Orthop. Traumatol. Surg. Res., (2016). https://doi.org/10.1016/j.otsr.2016.04.018.

    Article  Google Scholar 

  3. D. Bentouati, Y. Durgut, P. Otal, M. Plimmer, D. Prazak, W. Sabuga, S. Ehlers, E. Sinir, Calibration methods for negative gauge pressure down to − 100 kPa, Meas. Sci. Technol., 29 (2018) 035007.

    Article  ADS  Google Scholar 

  4. S. Saxholm, P. Otal, A. Altintas, L.G. Bermanec, Y. Durgut, R. Hanrahan, I. Kocas, A. Lefkopoulos, D. Prazak, I. Sandu, EURAMET.M.P-S9: comparison in the negative gauge pressure range − 950 to 0 hPa, Metrologia, 53(1A) (2016) 07010. https://doi.org/10.1088/0026-1394/53/1a/07010.

    Article  ADS  Google Scholar 

  5. M. Rantanen, S. Saxholm, A. Altintas, R. Pavis, G. Peterson, Supplementary comparison: negative gauge pressure comparison: range − 95 kPa to + 95 kPa (EURAMET Project 1131), Metrologia, 47(1A) (2010) 7007–07007. https://doi.org/10.1088/0026-1394/47/1a/07007.

    Article  ADS  Google Scholar 

  6. Z. Krajicek, M. Bergoglio, D. Prazak, S. Pasqualin, Final report on EURAMET.M.P-S12—bilateral supplementary comparison of the national pressure standards of CMI and INRIM in the range 300 Pa to 15 kPa of negative gauge pressure, Metrologia, 51(1A) (2014) 07010. https://doi.org/10.1088/0026-1394/51/1a/07010.

    Article  ADS  Google Scholar 

  7. J. Tesar, Z. Krajicek, D. Prazak, F. Stanek, Primary etalonnage of negative gauge pressures using pressure balances at the Czech Metrology Institute, Mater. Technol., 43(3) (2009) 151–156.

    Google Scholar 

  8. M.G. Cox, The evaluation of Key comparison data, Metrologia, 39 (2002) 589–595.

    Article  ADS  Google Scholar 

Download references

Acknowledgements

The author wishes to express his special thanks to Mr. Pierre Otal from LNE-France for his contribution in the training of Differential and Negative Pressure which was held by EU-TSP2 in 2015. Special thanks also to the management of SNSU-BSN for providing and maintaining the facilities in the pressure laboratory.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Adindra Vickar Ega.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ega, A.V., Ginanjar, G. & Samodro, R.R.A. Realization of Negative Gauge Pressure Standard in the National Metrology Institute of Indonesia. MAPAN 35, 97–103 (2020). https://doi.org/10.1007/s12647-019-00328-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12647-019-00328-6

Keywords

Navigation