Abstract
Evaluating the stray radiation around medical electron accelerators is a mandatory issue. Surveying the radiation leakage dose is important for patients, technicians, and health physicists, due to radiation protection aspects. Consequently, radiation leakage dose around the head of a mobile-dedicated intraoperative radiotherapy accelerator (LIAC), at different electron energies and field sizes have been evaluated in this study. More specifically, the MCNPX Monte Carlo code was used to model the LIAC head, connected applicator, and employed water phantom. Radiation leakage dose around the LIAC head was calculated for different energy and field sizes through tuning the Monte Carlo results to the practically measured doses. These measurements were performed using an Advance Markus ionization chamber inside an automated MP3-XS water phantom. The good agreement between the calculated dose distributions within the water tank and corresponding dose measurements show that the simulation model of the LIAC head is appropriate for radiation leakage assessment. The obtained radiation leakage dose distribution highly depends on the electron energy and applicator diameter. With increasing the electron energy, the leakage dose decreased, while increasing the field size increased the leakage dose. It is concluded that the rate of stray radiation and leakage dose around the LIAC head in both vertical and horizontal planes were acceptable according to the recommended radiation protection criteria. To meet the recommended dose limit (100 µSv/week for controlled areas), the maximum number of patients should be kept to four patients per week inside a standard and unshielded operating room.
Similar content being viewed by others
References
Baghani HR, Aghamiri SMR, Mahdavi SR, Akbari ME, Mirzaei HR (2015a) Comparing the dosimetric characteristics of the electron beam from dedicated intraoperative and conventional radiotherapy accelerators. J Appl Clin Med Phys 16:62–72
Baghani HR, Aghamiri SMR, Mahdavi SR, Robatjazi M, Zadeh AR, Akbari ME, Mirzaei HR, Nafissi N, Samsami M (2015b) Dosimetric evaluation of Gafchromic EBT2film for breast intraoperative electron radiotherapy verification. Phys Med 31:37–42
Beddar AS, Biggs PJ, Chang S, Ezzell GA, Faddegon BA, Hensley FW, Mills MD (2006) Intraoperative radiation therapy using mobile electron linear accelerators: report of AAPM Radiation Therapy Committee Task Group No. 72. Med Phys 33:1476–1489
Biggs P, Willett CG, Rutten H, Ciocca M, Gunderson LL, Calvo FA (2011) Intraoperative electron beam irradiation: physics and techniques. In: Gunderson LL, Willett CG, Calvo FA, Harrison LB (eds) Intraoperative irradiation: techniques and results. Humana Press, New York, pp 53–56
Cella L, Liuzzi R, Salvatore M (2010) The Italian affair: the employment of parallel plate ionization chambers for dose measurements in high dose-per-pulse IORT electron beams. Med Phys 37:2918–2924
Chadwick MB, Oblozinsky P, Blokhin A, Fukahori T, Han U, Lee YO, Martins MN, Varlamov VV, Yu B, Zhang J (2000) Handbook on photonuclear data for applications: cross sections and spectra, IAEA TECH-DOC 1178. IAEA, Vienna, pp 93–264
Ciocca M, Pedroli G, Orecchia R, Guido A, Cattani F, Cambria R, Veronesi U (2009) Radiation survey around a LIAC mobile electron linear accelerator for intraoperative radiation therapy. J Appl Clin Med Phys 10:131–138
Das IJ, Cheng CW, Watts RJ, Ahnesjö A, Gibbons J, Li XA, Lowenstein J, Mitra RK, Simon WE, Zhu TC (2008) Accelerator beam data commissioning equipment and procedures: report of the TG-106 of the therapy physics committee of the AAPM. Med Phys 35:4186–4215
Di Venanzio C, Marinelli M, Tonnetti A, Verona-Rinati G, Falco MD, Pimpinella M, Ciccotelli A, De Stefano S, Felici G, Marangoni F (2015) Characterization of a microDiamond detector in high-dose-per-pulse electron beams for intra operative radiation therapy. Phys Med 31:897–902
Heidarloo N, Baghani HR, Aghamiri SMR, Mahdavi SR, Akbari ME (2017) Commissioning of beam shaper applicator for conformal intraoperative electron radiotherapy. Appl Radiat Isot 123:69–81
Hosseini Aghdam MR, Baghani HR, Mahdavi SR, Aghamiri SMR, Akbari ME (2016) Monte Carlo study on effective source to surface distance for electron beams from a mobile dedicated IORT accelerator. J Radiother Pract 16:29–37
IAEA (2000) Absorbed dose determination in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water. TRS 398, Vienna
IAEA (2006) Radiation protection in the design of radiotherapy facilities. SRS 47, Vienna
ICRP (2007) The 2007 recommendations of the international commission on radiological protection. ICRP publication 103. Ann ICRP 37:2–4
Laitano R, Guerra A, Pimpinella M, Caporali C, Petrucci A (2006) Charge collection efficiency in ionization chambers exposed to electron beams with high dose per pulse. Phys Med Biol 51:6419–6436
LIAC technical report (2014) The mobile electron accelerator for intraoperative radiotherapy (IORT). http://www.sordina.com/download/Catalogo_IORT.pdf. Accessed 27 Feb 2018
Loi G, Dominietto M, Cannillo B, Ciocca M, Krengli M, Mones E, Negri E, Brambilla M (2006) Neutron production from a mobile linear accelerator operating in electron mode for intraoperative radiation therapy. Phys Med Biol 51:695–702
Low DA, Harms WB, Mutic S, Purdy JA (1998) A technique for the quantitative evaluation of dose distributions. Med Phys 25:656–661
Mills MD, Fajardo LC, Wilson DL, Daves JL, Spanos WJ (2001) Commissioning of a mobile electron accelerator for intraoperative radiotherapy. J Appl Clin Med Phys 2:121–130
NCRP (2005) Structural shielding design and evaluation for megavoltage X- and gamma-ray radiotherapy facilities: recommendations of the national council on radiation protection and measurements. NCRP 151, Bethesda
Righi S, Karaj E, Felici G, Di Martino F (2013) Dosimetric characteristics of electron beams produced by two mobile accelerators, Novac7 and Liac, for intraoperative radiation therapy through Monte Carlo simulation. J Appl Clin Med Phys 14:6–18
Robatjazi M, Mahdavi SR, Takavr A, Baghani HR (2015) Application of Gafchromic EBT2film for intraoperative radiation therapy quality assurance. Phys Med 31:314–319
Soriani A, Felici G, Fantini M, Paolucci M, Borla O, Evangelisti G, Benassi M, Strigari L (2010) Radiation protection measurements around a 12 MeV mobile dedicated IORT accelerator. Med Phys 37:995–1003
Strigari L, Soriani A, Landoni V, Teodoli S, Bruzzaniti V, Benassi M (2004) Radiation exposure of personnel during intraoperative radiotherapy (IORT): radiation protection aspects. J Exp Clin Cancer Res 23:489–494
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical approval
This article does not contain any studies with human participants or animals performed by any of the authors.
Informed consent
Informed consent was obtained from all individual participants involved in the study.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Baghani, H.R., Hosseini Aghdam, S.R., Robatjazi, M. et al. Monte Carlo-based determination of radiation leakage dose around a dedicated IOERT accelerator. Radiat Environ Biophys 58, 263–276 (2019). https://doi.org/10.1007/s00411-019-00786-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00411-019-00786-1