Skip to main content
Log in

Characteristics of Firebrands Collected from Actual Urban Fires

  • Published:
Fire Technology Aims and scope Submit manuscript

Abstract

The characteristics of firebrands collected from a recent urban fire in Japan are described. Specifically, this fire broke out from a Chinese restaurant in Itoigawa-city, Niigata, Japan on December 22nd 2016. On the day of the fire, strong winds resulted in rapid fire spread. With the presence of an average wind speed of 9 m/s, the fire quickly spread, resulting in the damage of 147 structures, with 120 of 147 destroyed. The fire was extinguished more than 30 h later. During the fire, firebrands were observed and 10 spot fires were reported. After the fire, investigations were performed and firebrands were collected from the burn site. The size and the mass of firebrands were measured and compared with the available literature data. It was observed that more than 60% of the collected firebrands had less than 0.10 g mass and 2.0 cm2 projected area and the size and the mass of firebrands were independent of the location. The size and the mass of firebrands from this fire were similar to those from another urban fire under similar wind speed and were also compared to those produced from a firebrand generator. The firebrand data set presented here provided valuable insights into how firebrands are generated from structures in actual urban fires. Finally, the description on how a firebrand generator may be used to produce firebrands similar to urban fires yields an important advancement to begin to study such complex phenomena in the laboratory.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9

Similar content being viewed by others

References

  1. Maranghides A et al. (2015) A case study of a community affected by the waldo fire—event timeline and defensive actions, NIST TN1910. http://dx.doi.org/10.6028/NIST.TN.1910

  2. National Research Institute of Fire and Disaster (1977) Fire Spread Behaviors of The Sakata Fire, Technical Report of National Research Institute of Fire and Disaster, No. 11, 1977 (in Japanese).

  3. Albini F (1979) Spot fire distances from burning trees—a predictive model, USDA Forest Service General Technical Report INT-56.

  4. Tarifa CS, del Notario PP, Moreno FG (1965) On the flight paths and lifetimes of burning particles of wood. Proc Combust Inst 10: 1021–1037

    Article  Google Scholar 

  5. Knight IK (2001) The design and construction of a vertical wind tunnel for the study of untethered firebrands in flight. Fire Tech 37: 87–100

    Article  Google Scholar 

  6. Wang HH (2011) Analysis on downwind distribution of firebrands sourced from a wildland fire. Fire Technol 47: 321–340

    Article  Google Scholar 

  7. Manzello SL (2014) Enabling the investigation of structure vulnerabilities to wind-driven firebrand showers in Wildland-Urban Interface (WUI) fires. Fire Saf Sci 11: 83–96. https://doi.org/10.3801/IAFSS.FSS.11-83

    Article  Google Scholar 

  8. Ohmiya Y, Iwami T (2000) An investigation on the distribution of firebrands and spot fires due to a hotel fire. Fire Sci Technol 20: 27–35

    Article  Google Scholar 

  9. Shinohara M, Sugii K, Hosokawa M (2012) The influence of characteristics of firebrands on the flight distance–based on the field survey of the city fire under the strong wind in Beppu-city, Oita, in January 2010-, Report of National Research Institute of Fire and Disaster, No. 113, Chofu, Tokyo (in Japanese)

  10. Suzuki S (2017) Study on characteristics of firebrands collected from three different fires’ NRIFD technical report 123, pp 1–9. September, 2017

  11. Manzello SL, Foote EID (2014) Characterizing firebrand exposure during wildland-urban interface fires: results of the 2007 Angora Fire. Fire Technol 50: 105–124

    Google Scholar 

  12. Rissel S, Ridenour K (2013) Ember production during the bastrop complex fire. Fire Manag Today 72: 7–13

    Google Scholar 

  13. Vodvarka FJ (1969) Firebrand field studies—Final Report, IIT Research Institute, Chicago, IL

  14. VodvarkaFJ (1970) Urban burns-full-scale field studies—Final Report, IIT Research Institute, Chicago, IL

  15. Yoshioka H, Hayashi Y, Masuda H, Noguchi T (2004) Real-scale fire wind tunnel experiment on generation of firebrand from a house on fire. Fire Sci Technol 23: 142–150

    Article  Google Scholar 

  16. Suzuki S, Manzello SL, Lage M, Laing G (2012) Firebrand generation data obtained from a full scale structure burn. Int J Wildland Fire 21: 961–968

    Article  Google Scholar 

  17. Suzuki S, Brown A, Manzello SL, Suzuki J, Hayashi Y (2014) Firebrands generated from a full-scale structure burning under well-controlled laboratory conditions. Fire Saf J 63: 43–51

    Article  Google Scholar 

  18. S. Suzuki SL, Manzello Y, Hayashi (2013) The size and mass distribution of firebrands collected from ignited building components exposed to wind. Proc Combust Inst 34 2479–2485

    Article  Google Scholar 

  19. Suzuki S, Manzello SL (2016) Firebrand production from building components fitted with siding treatments. Fire Saf J 80: 64–70.

    Article  Google Scholar 

  20. Manzello SL, Suzuki S (2017) Generating wind driven firebrand showers characteristics of burning structures. Proc Combust Inst 36: 3247–3252. doi: https://doi.org/10.1016/j.proci.2016.07.009

    Article  Google Scholar 

  21. Hasemi Y, Yasui N, Itagaki N, Izumi J, Osaka T, Kaku T, Naruse T, Hagiwara I, Kagiya K, Suzuki J, Kato K (2014) Full-scale fire tests of 3-story wooden school building. In: World conference on timber engineering, Quebec City, Canada, August, 2014

  22. Hayashi Y, Jaishi T, Izumi J, Naruse T, Itagaki N, Hashimoto R, Yasui N, Hasemi Y (2014) Firebrands deposition and measurements of collected firebrands generated and transported from a full-scale burn test using a large wooden building. AIJ J Technol Des 20: 605–610 (in Japanese)

    Article  Google Scholar 

  23. Japan Meteorological Agency website (http://www.data.jma.go.jp/obd/stats/etrn/view/10min_a1.php?prec_no=54&block_no=0539&year=2016&month=12&day=22&view=a2)

  24. Fire and Disaster Management Agency (2017) 13th Report of Large Fires in Itoigawa-city, Niigata (in Japanese)

  25. Fire and Disaster Management Agency (2017) ‘Committee report on fire prevention in the future, lesson learned from the Itoigawa-city fire’,. (in Japanese) http://www.fdma.go.jp/neuter/about/shingi_kento/h29/itoigawa_daikibokasai/06/houkokusyo.pdf

  26. Homes JD, Baker CJ, Tamura Y, (2006) Tachikawa number: a proposal. J Wind Eng Ind Aerodyn 94(1): 41–47

    Article  Google Scholar 

Download references

Acknowledgements

The assistance of residents in Itoigawa-city, Niigata, Japan and the help of Itoigawa-city Fire Department (FD) during the NRIFD investigations were greatly appreciated. The help of Drs. M. Shinohara and K. Suzuki, and Mr. K. Takanashi from Research and Development Division, and former investigation staffs, Mr. S. Fujisaki (currently with Sakura-city FD), T. Takagaki (currently with Saitama-city FD), M. Kuramochi (currently with Inashiki-Koiki FD), Y. Kawamori (currently with Shizuoka-city FD), and Y. Ichihashi (currently with Niigata-city FD) from Research and Investigation Division, NRIFD were appreciated. Data of Beppu-city fire was kindly provided by Dr. Shinohara. The authors thanked him for the help.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sayaka Suzuki.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Suzuki, S., Manzello, S.L. Characteristics of Firebrands Collected from Actual Urban Fires. Fire Technol 54, 1533–1546 (2018). https://doi.org/10.1007/s10694-018-0751-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10694-018-0751-x

Keywords

Navigation